1.
Phys Med ; 24(3): 159-68, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18468930

ABSTRACT

New solid-state detectors, based on chemical vapour deposited (CVD) polycrystalline diamonds produced by hot-filament (HF) or microwave plasma (MW) assisted deposition methods, were constructed for radiation therapy dosimetry. Properties of diamond crystals, such as high radiation sensitivity, resistance to radiation damage and tissue-equivalence giving a low-energy dependence are very advantageous for clinical dosimetry. Therefore the encapsulation was specially designed for these detectors to have as little influence as possible on the radiation response. The prototypes were irradiated with use of a wide range of photon beam qualities ((60)Co gamma-rays, 6 and 18 MV X-rays). The radiation sensitivity varied considerably between samples deposited with HF (9 nC Gy(-1)mm(-3)) and MW (66 and 144 nC Gy(-1)mm(-3)) methods. For all detectors the leakage current was of the order of 10% of the radiation-induced current (bias voltage 100 V, dose rate 0.3 Gy/min). When irradiated with (60)Co gamma-rays, the detectors showed a dose-rate linearity with an exponential Delta parameter close to unity. However, a difference of 8% was found between Delta values for the different beam qualities. A small energy dependence was observed, for which the most probable sources are interface effects due to the silver electrodes and partly the geometry of the encapsulation which needs to be further optimized. Despite some limitations in the performance of present prototype detectors, with an improved CVD technique producing crystals of better electrical and dosimetric properties, and with a well-designed tissue-equivalent encapsulation, CVD-diamonds could serve as very good dosimeters for radiotherapy.


Subject(s)
Diamond , Photons , Radiometry/methods , Radiation Dosage , Time Factors , Volatilization
2.
Med Phys ; 32(2): 389-95, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15789584

ABSTRACT

Three radiation detectors based on polycrystalline diamond films with different thickness and resistivity, obtained by microwave chemical vapor deposition, were tested to assess their suitability for relative dosimetry of photon and electron beams supplied by clinical linear accelerators. All samples showed a linear response as a function of the absorbed dose. The sensitivity per unit of detector sensitive volume spanned between 7 and 43 nC Gy(-1) mm(-3) with an applied electric field of 40 kV/cm. The dose rate dependence was evaluated following the Fowler theory and delta coefficient values between 0.95 and 1.00 were found for the three samples when polarized at 40 kV/cm. Percentage depth dose curves, output factors, and normalized dose profiles were determined for 6 and 10 MV photon beams and for 6 and 15 MeV electron beams. The results obtained with the diamond detectors were in good agreement with those obtained by reference detector measurements [all the data were within the experimental uncertainty of 1% (1sigma)].


Subject(s)
Diamond/chemistry , Diamond/radiation effects , Electrons/therapeutic use , Photons/therapeutic use , Radiometry/instrumentation , Radiotherapy/instrumentation , Transducers , Crystallization/methods , Dose-Response Relationship, Radiation , Equipment Design , Equipment Failure Analysis , Feasibility Studies , Particle Accelerators , Pilot Projects , Radiation Dosage , Radiometry/methods , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity