J Radiol Prot ; 2020 Jul 14.
Article in English | MEDLINE | ID: mdl-32663804

ABSTRACT

The aim of this multi-centre study was to evaluate the irradiation parameters and the radiation dose of abdomen CT exams without contrast, performed in adults In Brazil, in order to provide an overview of the CT installed base in the country and contribute for the establishment of optimization programs. Equipment of seven different models, with 16 and 64 channels, installed in 17 Brazilian states, plus the Federal District, were analyzed. The results show that the mean CTDIvol ranged from 6.60 mGy to 34.64 mGy. The results also showed that different irradiation parameters are used in equipment of the same model, resulting, in some cases, in three times higher CTDIvol values. These characteristics are not restricted to a given region of the country but distributed throughout the national territory. Repetitions of acquisitions and topograms with scan length larger than the region of interest were found in 13.5% of abdomen examinations, resulting in considerably higher absorbed doses than expected. This survey of the abdomen tomography exams, performed in about 74% of the Brazilian states, showed that in many clinics the procedures are not optimized. This study can be used for the planning of dose optimization programs and will contribute to the establishment of local diagnostic reference levels (DRL) for CT.