Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Cardiovasc Intervent Radiol ; 31(4): 723-7, 2008.
Article in English | MEDLINE | ID: mdl-18340484

ABSTRACT

The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters <18 mm and 30 (26%) patients had one or more CIA diameters >18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs >/=18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs >/=18 mm (p = 0.232). One-year freedom from IRSI was 92% +/- 3% and 84% +/- 9% for the <18-mm and >/=18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.


Subject(s)
Angioplasty/methods , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Iliac Artery/pathology , Radiography, Interventional/methods , Stents , Aged , Aged, 80 and over , Angiography/methods , Angioplasty/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis Implantation/mortality , Cohort Studies , Dilatation, Pathologic/diagnostic imaging , Dilatation, Pathologic/surgery , Female , Follow-Up Studies , Hospital Mortality/trends , Humans , Iliac Artery/diagnostic imaging , Kaplan-Meier Estimate , Male , Probability , Retrospective Studies , Risk Assessment , Severity of Illness Index , Survival Analysis , Tomography, X-Ray Computed/methods , Treatment Outcome
2.
J Vasc Interv Radiol ; 17(6): 973-7, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16778230

ABSTRACT

PURPOSE: To review the midterm results of endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) with the Talent stent-graft. MATERIALS AND METHODS: All patients who underwent EVAR of AAAs with Talent stent-grafts from February 1998 to April 2002 at a single institution were monitored for a minimum of 2 years or until an endpoint of death or rupture was reached. RESULTS: There were 68 eligible patients, who were monitored for a mean period of 39 months (range, 24-72 months). Forty-nine (72.9%) were alive at 2 years; among the 19 deaths, two resulted from aneurysm rupture and the other 17 were unrelated to EVAR. There was one immediate conversion to open repair and five primary proximal endoleaks; the remaining 62 patients (91.2%) all had a technically successful procedure. There were 33 endoleaks during follow-up: 23 (69.7%) were treated conservatively and 10 (30.3%) underwent secondary intervention in the form of embolization (n=2), attempted embolization (n=2), endovascular stent-graft placement (n=3), combined stent-graft placement and embolization (n=1), or surgical conversion (n=2). Overall, there were five persistent endoleaks, and the remaining patients were free of endoleak at their last review or endpoint. Three stent-grafts migrated and required further endovascular intervention. Wire fracture was seen in two stents but presented no clinical sequelae. There was one case of graft limb thrombosis that required surgical thrombectomy. CONCLUSIONS: EVAR of AAAs with use of the Talent stent-graft is a promising and acceptable alternative to open surgery. Our 30-day mortality rate of zero compares extremely well with historical data from open surgery and the findings of more recently published trials. The risk of endoleak and uncertainty over durability require long-term surveillance.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Contrast Media , Female , Follow-Up Studies , Humans , Iohexol , Male , Middle Aged , Postoperative Complications , Treatment Outcome , Ultrasonography
3.
J Vasc Interv Radiol ; 15(12): 1399-405, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15590796

ABSTRACT

PURPOSE: Device migration (DM) may cause late failure after endovascular aortic aneurysm repair (EVAR). Computed tomography (CT) scans following EVAR were reviewed to establish the frequency of DM and whether it can be predicted. MATERIALS AND METHODS: Fifty-five patients underwent EVAR with a Talent stent-graft with suprarenal fixation. CT with a fixed protocol was performed at regular intervals. Patient demographics, risk factors, procedure details, and follow-up events were reviewed. Two observers, blinded to each other, reviewed axial images and mutliplanar reformats of the CT scans. DM was defined as a change of > or = 10 mm in the distance between a reference vessel (celiac axis/superior mesenteric artery) and the proximal device. Follow-up was performed for a minimum of 2 years (mean, 3 years; range, 2-5 years). RESULTS: DM was detected in six of 38 patients (15.8%) by 2 years. There were no new cases of migration in the 19 patients at 3 years but one new case in the six patients at 4 years (16.6%). Mean migration over 2 years was 4.8 mm +/- 4.2 mm. One patient with DM developed a type I endoleak that required reintervention. This patient developed a further endoleak and died following surgery for rupture. Top neck enlargement was the only predictive factor identified, present in 71% of patients with DM (P = .056). CONCLUSION: DM occurred in a small proportion of patients; closer follow-up intervals may be necessary in patients with short/enlarging proximal necks.


Subject(s)
Aortic Aneurysm, Abdominal/therapy , Blood Vessel Prosthesis , Foreign-Body Migration/diagnostic imaging , Stents , Aged , Aged, 80 and over , Chi-Square Distribution , Female , Humans , Male , Middle Aged , Risk Factors , Tomography, X-Ray Computed , Treatment Outcome
5.
J Vasc Interv Radiol ; 14(8): 1011-6, 2003 Aug.
Article in English | MEDLINE | ID: mdl-12902558

ABSTRACT

PURPOSE: Evaluation of the Talent endovascular aortic stent graft in the management of abdominal aortic aneurysms. MATERIALS AND METHODS: Thirty-eight patients with suitable abdominal aortic aneurysms were treated over an 18-month period using the modular Talent stent graft. The suprarenal Talent device was deployed in 31 cases. Clinical follow-up of all patients has been performed by clinical examination, contrast-enhanced CT, and Duplex ultrasound for a mean period of 12.5 months. RESULTS: Graft placement was successful in all 38 patients. The immediate exclusion rate was 84%, the 1-month primary exclusion rate was 92.1%, and the 3-month exclusion rate was 97%. There were no deaths in the first 30 days, one death at 3 months due to a presumed rupture, and one other death at 1 year due to carcinomatosis. There have been no migrations or renal complications in the suprarenal group. CONCLUSIONS: Our short- and medium-term results are comparable with other published Talent stent-graft series. Suprarenal graft fixation is a safe procedure that may aid in preventing graft migration. Long-term follow-up is required to assess the durability of the suprarenal Talent device.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Stents , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation , Female , Follow-Up Studies , Humans , Male , Postoperative Complications/epidemiology , Prosthesis Design , Time Factors , Tomography, Spiral Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...