Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 74
Filter
1.
Article in English | MEDLINE | ID: mdl-38848005

ABSTRACT

Many lesions in patients undergoing percutaneous coronary intervention (PCI) exhibit significant calcification. Several techniques have been developed to improve outcomes in this setting. However, their impact on coronary microcirculation remains unknown. The aim of this study is to evaluate the influence of plaque modification techniques on coronary microcirculation across patients with severely calcified coronary artery disease. In this multicenter retrospective study, consecutive patients undergoing PCI with either Rotablation (RA) or Shockwave-intravascular-lithotripsy (IVL) were included. Primary endpoint was the impairment of coronary microvascular resistances assessed by Δ angiography-derived index of microvascular resistance (ΔIMRangio) which was defined as the difference in IMRangio value post- and pre-PCI. Secondary endpoints included the development of peri procedural PCI complications (flow-limiting coronary dissection, slow-flow/no reflow during PCI, coronary perforation, branch occlusion, failed PCI, stroke and shock developed during PCI) and 12-month follow-up adverse events. 162 patients were included in the analysis. Almost 80% of patients were male and the left descending anterior artery was the most common treated vessel. Both RA and IVL led to an increase in ΔIMRangio (22.3 and 10.3; p = 0.038, respectively). A significantly higher rate of PCI complications was observed in patients with ΔIMRangio above the median of the cohort (21.0% vs. 6.2%; p = 0.006). PCI with RA was independently associated with higher ΔIMRangio values (OR 2.01, 95% CI: 1.01-4.03; p = 0.048). Plaque modification with IVL and RA during PCI increases microvascular resistance. Evaluating the microcirculatory status in this setting might help to predict clinical and procedural outcomes and to optimize clinical results.

2.
Article in English, Spanish | MEDLINE | ID: mdl-38763211

ABSTRACT

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup for transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains largely unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length > 60 mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiovascular death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.44; 95%CI, 1.09-1.83; P = .009). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

3.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38554125

ABSTRACT

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Subject(s)
Aortic Valve Stenosis , Benchmarking , Length of Stay , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Male , Female , Aged, 80 and over , Length of Stay/statistics & numerical data , Aged , Critical Pathways , Europe/epidemiology , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Patient Safety
4.
Expert Rev Med Devices ; 21(3): 187-196, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38155555

ABSTRACT

INTRODUCTION: Over the last two decades, mitral transcatheter edge-to-edge repair (M-TEER) has become a safe and effective therapy for severe mitral regurgitation in patients deemed at high surgical risk. AREAS COVERED: This review aims to encompass the most relevant and updated evidence in the field of M-TEER from its inception, focusing on clinical and anatomical features for proper patient and device selection. EXPERT OPINION: Growing operator experience and device iterations have resulted in improved clinical outcomes and an expansion of the therapy to patients with complex anatomies and clinical scenarios. Future investigations are warranted to determine the best management options and the most suitable device for every patient with MR.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Patient Selection , Mitral Valve Insufficiency/surgery , Treatment Outcome
5.
Expert Rev Cardiovasc Ther ; 21(10): 703-712, 2023.
Article in English | MEDLINE | ID: mdl-37815845

ABSTRACT

INTRODUCTION: With the expanding indications of transcatheter aortic valve replacement (TAVR) to younger and low-risk patients, the life expectancy of patients currently undergoing TAVR will likely outlive the durability of transcatheter bioprosthesis. Consequently, the number of failed transcatheter bioprosthesis requiring surgical valve explant or redo TAVR is expected to increase. AREAS COVERED: The aim of this review is to provide an updated overview of redo TAVR for treating degenerated transcatheter bioprosthesis, focusing on pre-procedural planning, potential challenges of coronary reaccess during TAVR-in-TAVR and main outcomes of TAVR explant and redo TAVR. EXPERT OPINION: Patient-tailored device selection and individualized implantation height should be carefully assessed during the index TAVR procedure (weighting between pacemaker avoidance and the potential risk of coronary occlusion in future TAVR-in-TAVR). Future prospective studies comparing safety and clinical outcomes between redo TAVR vs TAVR explant are eagerly awaited.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Bioprosthesis/adverse effects , Aortic Valve Stenosis/surgery , Prospective Studies , Prosthesis Design , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Risk Factors
7.
JACC Cardiovasc Interv ; 16(17): 2153-2164, 2023 09 11.
Article in English | MEDLINE | ID: mdl-37704301

ABSTRACT

BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.


Subject(s)
Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Percutaneous Coronary Intervention/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Hemorrhage/chemically induced , Catheters
8.
JACC Cardiovasc Interv ; 16(18): 2277-2290, 2023 09 25.
Article in English | MEDLINE | ID: mdl-37758382

ABSTRACT

BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Stroke Volume , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Risk Factors , Ventricular Function, Left , Treatment Outcome , Arrhythmias, Cardiac/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
9.
J Clin Med ; 12(18)2023 Sep 18.
Article in English | MEDLINE | ID: mdl-37762965

ABSTRACT

Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for patients aged ≥75 years with severe aortic stenosis. Preoperative anemia is present in a large proportion of patients and may increase the risk of post-procedural complications. The purpose of this prognostic systematic review was to analyze the impact of baseline anemia on short- and mid-term outcomes following TAVR. A computerized search was performed on PubMed and Web of Science databases for studies published between January 2013 and December 2022. Primary outcomes were 30-day need for transfusion, acute renal failure, 30-day and mid-term mortality, and readmission during the first year post-TAVR. Data were analyzed via random effects model using inverse variance method with 95% confidence intervals. Eleven observational studies met our eligibility criteria and included a total of 12,588 patients. The prevalence of baseline anemia ranged between 39% and 72%, with no relevant sex differences. Patients with preprocedural anemia received more blood transfusions [OR: 2.95 (2.13-4.09)]), and exhibited increased rates of acute kidney injury [OR:1.74 (1.45-2.10)], short-term mortality [OR: 1.47 (1.07-2.01], and mid-term [OR: 1.89 (1.58-2.25)] mortality following TAVR compared with those without anemia. Baseline anemia determined an increased risk for blood transfusion, acute kidney injury, and short/mid-term mortality among TAVR recipients.

10.
Int J Gen Med ; 16: 4257-4265, 2023.
Article in English | MEDLINE | ID: mdl-37750105

ABSTRACT

Background: The percutaneous treatment of heart valve diseases carried out in the hemodynamic service is constantly growing. After analyzing the mortality, readmissions, success of the procedure, and complications, several studies support this type of percutaneous procedure. The increase in these procedures has required the creation of multidisciplinary teams and new diagnostic and care circuits, such as presurgical consultations and postsurgical follow-ups. Even so, there is little evidence regarding the effect of these consultations on quality indicators. Purpose: The objective of this study is to evaluate the impact of a program of presurgical and postsurgical nurse interventions (PROCESS-VALVE) on quality indicators of the health of patients undergoing percutaneous valve procedures. Patients and Methods: The influence of presurgical and postsurgical consultations on quality indicators will be evaluated through an ambispective quasi-experimental study. Patients will be recruited at a tertiary-level hospital in Barcelona, Spain. For the control group, data will be collected retrospectively from patients who underwent percutaneous valve procedures but did not receive pre- or postsurgical consultations. The intervention group comprises those patients agreeing to participate in the study and the hemodynamic nurse valve consultation program (PROCESS-VALVE). In addition, we will assess whether a face-to-face postsurgical consultation equally improves quality indicators compared to postsurgical telephone consultation; for this, a sub-study will be carried out comparing face-to-face or telephone postsurgical follow-up by means of a randomized controlled clinical trial with simple blinding in the intervention group. Discussion: This study will generate scientific evidence regarding the impact on quality indicators of a nursing intervention via presurgical and postsurgical consultations. In addition, it will allow us to decide the most appropriate follow-up strategy for this type of patient. Trial Registration: ClinicalTrials.gov NCT05179278, registration date 01/05/2022.

11.
Clin Res Cardiol ; 112(12): 1790-1799, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37294311

ABSTRACT

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) is associated with adverse outcomes, i.e. ischemic stroke or systemic embolism (SE). Data on predictors of stroke/SE in the context of DRT are limited. AIMS: This study aimed to identify predisposing factors for stroke/SE in DRT patients. In addition, the temporal connection of stroke/SE to DRT diagnosis was analyzed. METHODS: The EUROC-DRT registry included 176 patients, in whom DRT after LAAC were diagnosed. Patients with symptomatic DRT, defined as stroke/SE in the context of DRT diagnosis, were compared against patients with non-symptomatic DRT. Baseline characteristics, anti-thrombotic regimens, device position, and timing of stroke/SE were compared. RESULTS: Stroke/SE occurred in 25/176 (14.2%) patients diagnosed with DRT (symptomatic DRT). Stroke/SE occurred after a median of 198 days (IQR 37-558) after LAAC. In 45.8% stroke/SE occurred within one month before/after DRT diagnosis (DRT-related stroke). Patients with symptomatic DRT had lower left ventricular ejection fractions (50.0 ± 9.1% vs. 54.2 ± 11.0%, p = 0.03) and higher rates of non-paroxysmal atrial fibrillation (84.0% vs. 64.9%, p = 0.06). Other baseline parameters and device positions were not different. Most ischemic events occurred among patients with single antiplatelet therapy (50%), however, stroke/SE was also observed under dual antiplatelet therapy (25%) or oral anticoagulation (20%). CONCLUSION: Stroke/SE are documented in 14.2% and occur both in close temporal relation to the DRT finding and chronologically independently therefrom. Identification of risk factors remains cumbersome, putting all DRT patients at substantial risk for stroke/SE. Further studies are necessary to minimize the risk of DRT and ischemic events.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thrombosis , Humans , Treatment Outcome , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Thrombosis/diagnosis , Thrombosis/epidemiology , Thrombosis/etiology , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Registries , Atrial Appendage/diagnostic imaging
12.
JACC Cardiovasc Interv ; 16(10): 1208-1217, 2023 05 22.
Article in English | MEDLINE | ID: mdl-37225292

ABSTRACT

BACKGROUND: Coronary obstruction (CO) following transcatheter aortic valve replacement (TAVR) is a life-threatening complication, scarcely studied. OBJECTIVES: The authors analyzed the incidence of CO after TAVR, presentation, management, and in-hospital and 1-year clinical outcomes in a large series of patients undergoing TAVR. METHODS: Patients from the Spanish TAVI (Transcatheter Aortic Valve Implantation) registry who presented with CO in the procedure, during hospitalization or at follow-up were included. Computed tomography (CT) risk factors were assessed. In-hospital, 30-day, and 1-year all-cause mortality rates were analyzed and compared with patients without CO using logistic regression models in the overall cohort and in a propensity score-matched cohort. RESULTS: Of 13,675 patients undergoing TAVR, 115 (0.80%) presented with a CO, mainly during the procedure (83.5%). The incidence of CO was stable throughout the study period (2009-2021), with a median annual rate of 0.8% (range 0.3%-1.3%). Preimplantation CT scans were available in 105 patients (91.3%). A combination of at least 2 CT-based risk factors was less frequent in native than in valve-in-valve patients (31.7% vs 78.3%; P < 0.01). Percutaneous coronary intervention was the treatment of choice in 100 patients (86.9%), with a technical success of 78.0%. In-hospital, 30-day, and 1-year mortality rates were higher in CO patients than in those without CO (37.4% vs 4.1%, 38.3% vs 4.3%, and 39.1% vs 9.1%, respectively; P < 0.001). CONCLUSIONS: In this large, nationwide TAVR registry, CO was a rare, but often fatal, complication that did not decrease over time. The lack of identifiable predisposing factors in a subset of patients and the frequently challenging treatment when established may partly explain these findings.


Subject(s)
Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Catheters , Registries
13.
Card Electrophysiol Clin ; 15(2): 193-200, 2023 06.
Article in English | MEDLINE | ID: mdl-37076231

ABSTRACT

Left atrial appendage closure aims to eliminate the stasis component of Virchow triad by eliminating a cul-de-sac that favors thrombosis, particularly when atrial contractility becomes inefficient, such as in atrial fibrillation. Left atrial appendage closure devices have a common objective of sealing the appendage completely, with device stability and avoidance of device thrombosis. Two main device designs have been used to perform left atrial appendage closure: those that use a pacifier design (lobe + disk) and those that use a plug (single lobe) design. This review highlights the potential features and benefits of the single-lobe devices.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Thrombosis , Humans , Follow-Up Studies , Treatment Outcome , Echocardiography, Transesophageal , Atrial Fibrillation/surgery , Thrombosis/prevention & control , Cardiac Catheterization
14.
Circ Cardiovasc Interv ; 16(3): e012554, 2023 03.
Article in English | MEDLINE | ID: mdl-36943930

ABSTRACT

BACKGROUND: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. METHODS: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm2. A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. RESULTS: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39-3.65; P=0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11-3.09]; P=0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41-1.45]; P=0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. CONCLUSIONS: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Prosthesis Design
15.
Rev Esp Cardiol (Engl Ed) ; 76(10): 767-773, 2023 Oct.
Article in English, Spanish | MEDLINE | ID: mdl-36804557

ABSTRACT

INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Prospective Studies , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Treatment Outcome , Cardiac Conduction System Disease , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
16.
Rev Esp Cardiol (Engl Ed) ; 76(1): 25-31, 2023 Jan.
Article in English, Spanish | MEDLINE | ID: mdl-35691867

ABSTRACT

INTRODUCTION AND OBJECTIVES: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. METHODS: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. RESULTS: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). CONCLUSIONS: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Female , Aged , Male , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/adverse effects , Treatment Outcome
17.
J Am Heart Assoc ; 11(20): e023121, 2022 10 18.
Article in English | MEDLINE | ID: mdl-36216434

ABSTRACT

Background Malnutrition is associated with poor prognosis in several cardiovascular diseases. However, its prognostic impact in patients undergoing transcatheter edge-to-edge mitral valve repair (TEER) is not well known. This study sought to assess the prevalence, clinical associations, and prognostic consequences of malnutrition in patients undergoing TEER. Methods and Results A total of 892 patients undergoing TEER from the international MIVNUT (Mitral Valve Repair and Nutritional Status) registry were studied. Malnutrition status was assessed with the Controlling Nutritional Status score. The association of nutritional status with mortality was analyzed with multivariable Cox regression models, whereas the association with heart failure admission was assessed by Fine-Gray models, with death as a competing risk. According to the Controlling Nutritional Status score, 74.4% of patients with TEER had any degree of malnutrition at the time of TEER (75.1% in patients with body mass index <25 kg/m2, 72.1% in those with body mass index ≥25 kg/m2). However, only 20% had moderate-severe malnutrition. TEER was successful in most of patients (94.2%). During a median follow-up of 1.6 years (interquartile range, 0.6-3.0), 267 (29.9%) patients died and 256 patients (28.7%) were admitted for heart failure after TEER. Compared with normal nutritional status moderate-severe malnutrition resulted a strong predictor of mortality (adjusted hazard ratio [HR], 2.1 [95% CI, 1.1-2.4]; P<0.001) and heart failure admission (adjusted subdistribution HR, 1.6 [95% CI, 1.1-2.4]; P=0.015). Conclusions Malnutrition is common among patients submitted to TEER, and moderate-severe malnutrition is strongly associated with increased mortality and heart failure readmission. Assessment of nutritional status in these patients may help to improve risk stratification.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Malnutrition , Mitral Valve Insufficiency , Humans , Nutritional Status , Prognosis , Mitral Valve/surgery , Risk Factors , Malnutrition/diagnosis , Malnutrition/epidemiology , Heart Failure/etiology , Registries , Mitral Valve Insufficiency/surgery , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
18.
Rev Port Cardiol ; 41(2): 177.e1-177.e4, 2022 Feb.
Article in English, Portuguese | MEDLINE | ID: mdl-36062706

ABSTRACT

Management of patients with congenital heart defects and associated pulmonary arterial hypertension remains a major concern. With evolving targeted drug therapies and new iterations of transcatheter devices, treatment of appropriately selected patients with severe pulmonary hypertension, classically considered inoperable, has become feasible. We report the case of a patient with concomitant ruptured right sinus of Valsalva aneurysm and ventricular septal defect, with early reversal of suprasystemic pulmonary pressures following successful percutaneous closure of ruptured sinus of Valsalva.

19.
JACC Clin Electrophysiol ; 8(9): 1093-1102, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36137713

ABSTRACT

BACKGROUND: Left atrial appendage closure (LAAC) aims to prevent ischemic events in patients with atrial fibrillation. As a preventive procedure, early death after LAAC could render the procedure futile. OBJECTIVES: The authors sought to evaluate the incidence and factors associated with early death in LAAC recipients. METHODS: This was a multicenter study including consecutive patients undergoing LAAC in a 10-year period (2009-2019). Death was considered early when occurring in the first year after LAAC. RESULTS: A total of 807 patients (mean age 76 ± 8 years, mean CHA2DS2-VASc score 4.5 ± 1.5) were included. Early death occurred in 125 patients (15.5%). In the multivariable analysis, factors associated with early death after LAAC were older age HR: 1.03; 95% CI: 1.01-1.06 per year; P = 0.01), lower body mass index (HR: 0.92; 95% CI: 0.88-0.97 per 1 kg/m2 increase; P < 0.001), diabetes (HR: 1.71; 95% CI: 1.19-2.47; P = 0.002), prior heart failure (HR: 1.74; 95% CI: 1.20-2.53; P = 0.001), and lower estimated glomerular filtration rate (HR: 1.09; 95% CI: 1.05-1.13 per 5 mL/min/1.73 m2 decrease; P < 0.001). There was a stepwise increase in risk of early death within the first year of LAAC with the combination of different risk factors (up to 48.9% in the presence of >3 risk factors). CONCLUSIONS: In this multicenter international registry, close to 1 in 6 patients died within the first year of LAAC. Older age, low body mass index, impaired estimated glomerular filtration rate, prior diabetes, and prior heart failure are independently associated with an increased risk. The risk of early death appeared to be prohibitive (∼50%) in the presence of >3 of these risk factors.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Heart Failure , Stroke , Aged , Aged, 80 and over , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Humans , Incidence , Stroke/epidemiology
20.
J Pers Med ; 12(9)2022 Aug 30.
Article in English | MEDLINE | ID: mdl-36143197

ABSTRACT

Device-related thrombus (DRT) after left atrial appendage (LAA) closure is infrequent but correlates with an increased risk of thromboembolism. Therefore, the search for DRT predictors is a topic of interest. In the literature, multivariable methods have been used achieving non-consistent results, and to the best of our knowledge, machine learning techniques have not been used yet for thrombus detection after LAA occlusion. Our aim is to compare both methodologies with respect to predictive power and the search for predictors of DRT. To this end, a multicenter study including 1150 patients who underwent LAA closure was analyzed. Two lines of experiments were performed: with and without resampling. Multivariate and machine learning methodologies were applied to both lines. Predictive power and the extracted predictors for all experiments were gathered. ROC curves of 0.5446 and 0.7974 were obtained for multivariate analysis and machine learning without resampling, respectively. However, the resampling experiment showed no significant difference between them (0.52 vs. 0.53 ROC AUC). A difference between the predictors selected was observed, with the multivariable methodology being more stable. These results question the validity of predictors reported in previous studies and demonstrate their disparity. Furthermore, none of the techniques analyzed is superior to the other for these data.

SELECTION OF CITATIONS
SEARCH DETAIL
...