1.
J Thromb Haemost ; 15(8): 1576-1583, 2017 08.
Article in English | MEDLINE | ID: mdl-28574652

ABSTRACT

Essentials Accurate determination of anticoagulant plasma concentration is important in clinical practice. We studied the accuracy and consistency of anti-Xa assays for rivaroxaban in a multicentre study. In a range between 50 and 200 µg L-1 , anti-Xa activity correlated well with plasma concentrations. The clinical value might be limited by overestimation and intra- and inter-individual variation. SUMMARY: Background Determining the plasma level of direct oral anticoagulants reliably is important in the work-up of complex clinical situations. Objectives To study the accuracy and consistency of anti-Xa assays for rivaroxaban plasma concentration in a prospective, multicenter evaluation study employing different reagents and analytical platforms. Methods Rivaroxaban 20 mg was administered once daily to 20 healthy volunteers and blood samples were taken at peak and trough levels (clinicaltrials.gov NCT01710267). Anti-Xa activity was determined in 10 major laboratories using different reagents and analyzers; corresponding rivaroxaban plasma concentrations were measured by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS). Findings Overall Pearson's correlation coefficient of anti-Xa levels and HPLC-MS results was 0.99 for Biophen® Heparin (95% CI, 0.99, 0.99), Biophen® DiXaI (95% CI, 0.99, 0.99) and STA® anti-Xa liquid (95% CI, 0.99, 1.00). Correlation was lower in rivaroxaban concentrations below 50 µg L-1 and above 200 µg L-1 . The overall bias of the Bland-Altman difference plot was 14.7 µg L-1 for Biophen Heparin, 17.9 µg L-1 for Biophen DiXal and 19.0 µg L-1 for STA anti-Xa liquid. Agreement between laboratories was high at peak level but limited at trough level. Conclusions Anti-Xa activity correlated well with rivaroxaban plasma concentrations, especially in a range between 50 and 200 µg L-1 . However, anti-Xa assays systematically overestimated rivaroxaban concentration as compared with HPLC-MS, particularly at higher concentrations. This overestimation, coupled with an apparent interindividual variation, might affect the interpretation of results in some situations.


Subject(s)
Blood Coagulation/drug effects , Drug Monitoring/methods , Factor Xa Inhibitors/blood , Factor Xa/metabolism , Rivaroxaban/blood , Administration, Oral , Adolescent , Adult , Aged , Chromatography, High Pressure Liquid , Factor Xa Inhibitors/administration & dosage , Healthy Volunteers , Humans , Laboratory Proficiency Testing , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Rivaroxaban/administration & dosage , Switzerland , Tandem Mass Spectrometry , Young Adult
2.
Haemophilia ; 23(4): e335-e339, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28544263

ABSTRACT

INTRODUCTION: Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. AIM: Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. METHODS: Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. RESULTS: When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. CONCLUSION: In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard.


Subject(s)
Biological Assay/standards , Factor VIII/chemistry , Factor VIII/metabolism , Polyethylene Glycols/chemistry , Recombinant Proteins/chemistry , Recombinant Proteins/metabolism , Reference Standards , Switzerland
3.
Br J Anaesth ; 114(2): 217-24, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25204698

ABSTRACT

Standard laboratory coagulation tests (SLTs) such as prothrombin time/international normalized ratio or partial thromboplastin time are frequently used to assess coagulopathy and to guide haemostatic interventions. However, this has been challenged by numerous reports, including the current European guidelines for perioperative bleeding management, which question the utility and reliability of SLTs in this setting. Furthermore, the arbitrary definition of coagulopathy (i.e. SLTs are prolonged by more than 1.5-fold) has been questioned. The present study aims to review the evidence for the usefulness of SLTs to assess coagulopathy and to guide bleeding management in the perioperative and massive bleeding setting. Medline was searched for investigations using results of SLTs as a means to determine coagulopathy or to guide bleeding management, and the outcomes (i.e. blood loss, transfusion requirements, mortality) were reported. A total of 11 guidelines for management of massive bleeding or perioperative bleeding and 64 studies investigating the usefulness of SLTs in this setting were identified and were included for final data synthesis. Referenced evidence for the usefulness of SLTs was found in only three prospective trials, investigating a total of 108 patients (whereby microvascular bleeding was a rare finding). Furthermore, no data from randomized controlled trials support the use of SLTs. In contrast, numerous investigations have challenged the reliability of SLTs to assess coagulopathy or guide bleeding management. There is actually no sound evidence from well-designed studies that confirm the usefulness of SLTs for diagnosis of coagulopathy or to guide haemostatic therapy.


Subject(s)
Blood Coagulation Disorders/diagnosis , Blood Coagulation Disorders/therapy , Blood Coagulation Tests , Hemorrhage/diagnosis , Hemorrhage/therapy , Perioperative Care/methods , Evidence-Based Medicine , Humans , Intraoperative Complications/diagnosis , Intraoperative Complications/therapy , Postoperative Complications/diagnosis , Postoperative Complications/therapy
4.
Thromb Haemost ; 112(1): 109-17, 2014 Jul 03.
Article in English | MEDLINE | ID: mdl-24633448

ABSTRACT

Plasma fibrinogen concentration is important for coagulopathy assessment, and is most commonly measured using the Clauss method. Several factors, including device type and reagent, have been shown to affect results. The study objective was to evaluate performance and repeatability of the Clauss method and to assess differences between measurements performed during and after cardiopulmonary bypass (CPB), by testing plasma samples from patients undergoing cardiac surgery with CPB. Samples were collected from 30 patients before surgery, approximately 20 minutes before weaning from CPB, and 5 minutes after CPB and protamine. Fibrinogen concentration was determined using the Clauss method at six quality-controlled specialised laboratories, according to accredited standard operating procedures. Regarding within-centre agreement for Clauss measurement, mean differences between duplicate measurements were between 0.00 g/l and 0.15 g/l, with intervals for 95% limits of agreement for mean Bland-Altman differences up to 1.3 g/l. Regarding between-centre agreement, some mean differences between pairs of centres were above 0.5 g/l. Differences of up to ~2 g/l were observed with individual samples. Increased variability was observed between centres, with inter-class correlation values below 0.5 suggesting only fair agreement. There were no significant differences in fibrinogen concentration before weaning from CPB and after CPB for most centres and methods. In conclusion, considerable differences exist between Clauss-based plasma fibrinogen measured using different detection methods. Nevertheless, the similarity between measurements shortly before weaning from CPB and after CPB within centres suggests that on-pump measurements could provide an early estimation of fibrinogen deficit after CPB and thus guidance for haemostatic therapy.


Subject(s)
Blood Coagulation Disorders/diagnosis , Blood Coagulation Tests/methods , Cardiopulmonary Bypass , Fibrinogen/metabolism , Plasma/metabolism , Blood Coagulation Disorders/epidemiology , Blood Coagulation Disorders/surgery , Humans , Laboratories/statistics & numerical data , Nephelometry and Turbidimetry , Observer Variation , Quality Control , Reproducibility of Results
5.
Thromb Res ; 129(4): 492-8, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21840043

ABSTRACT

INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43µg/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.


Subject(s)
Artifacts , Blood Coagulation Tests/methods , Drug Monitoring/methods , Factor Xa Inhibitors , Morpholines/blood , Thiophenes/blood , Adult , Anticoagulants/blood , Humans , Male , Reproducibility of Results , Rivaroxaban , Sensitivity and Specificity , Switzerland
6.
Swiss Med Wkly ; 141: w13243, 2011.
Article in English | MEDLINE | ID: mdl-21805405

ABSTRACT

Systemic treatment with bevacizumab is associated with increased rates of arterial and venous thromboembolism and haemorrhage. In order to investigate the pathophysiological mechanism involved, platelet adhesive and aggregatory functions were tested with a platelet function analyser (PFA-100®) in an in vitro study and in a longitudinal clinical observation study. For the in vitro study, blood from ten healthy volunteers was incubated with different concentrations of bevacizumab (0-1000 µg/ml plasma) and vascular endothelial growth factor (0-500 µg/ml). In the clinical observation study, PFA-100® closure times (CTs) and soluble P-selectin (sP-selectin) serum levels as a serological marker of platelet activation were assessed in 20 patients with metastatic cancer who were treated with bevacizumab in addition to cytotoxic chemotherapy. No significant changes of PFA-100® CTs were observed in the in vitro study. In the clinical observation study, mean PFA-100® CTs after treatment with bevacizumab were unchanged. sP-selectin was decreased after bevacizumab infusion by 18% (p = 0.045), which could suggest an inhibitory action on platelets. Our data do not support the view that increased platelet activation or increased platelet adhesiveness and aggregation by bevacizumab are relevant mechanisms for thrombus formation in clinical practice.


Subject(s)
Angiogenesis Inhibitors/pharmacology , Antibodies, Monoclonal, Humanized/pharmacology , Platelet Adhesiveness/drug effects , Platelet Aggregation/drug effects , Adult , Aged , Aged, 80 and over , Antigens/blood , Antigens/immunology , Bevacizumab , Cells, Cultured , Female , Humans , Male , Middle Aged , P-Selectin/blood , Platelet Function Tests , Vascular Endothelial Growth Factor A/pharmacology , von Willebrand Factor/immunology
7.
Br J Anaesth ; 106(4): 505-11, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21310721

ABSTRACT

BACKGROUND: Indications, efficacy, and safety of plasma products are highly debated. We compared the concentrations of haemostatic proteins and cytokines in solvent/detergent-treated plasma (SDP) and fresh-frozen plasma (FFP). METHODS: Concentrations of the following parameters were measured in 25 SDP and FFP samples: fibrinogen (FBG), factor (F) II, F V, F VII, F VIII, F IX, F X, F XIII, von Willebrand factor (vWF), D-Dimers, ADAMTS-13 protease, tumour necrosis factor-α (TNF-α), interleukin (IL)-1ß, IL-6, IL-8, and IL-10. RESULTS: Mean FBG concentrations in SDP and FFP were similar, but in FFP, the range was larger than in SDP (P<0.01). Mean F II, F VII, F VIII, F IX, and F XIII levels did not differ significantly. Higher concentrations of F V (P<0.01), F X (P<0.05), vWF (P<0.01), and ADAMTS-13 (P<0.01) were found in FFP. With the exception of F VIII and F IX, the range of concentrations for all of these factors was smaller (P<0.05) in SDP than in FFP. Concentrations of TNF-α, IL-8, and IL-10 (all P<0.01) were higher in FFP than in SDP, again with a higher variability and thus larger ranges (P<0.01). CONCLUSIONS: Coagulation factor content is similar for SDP and FFP, with notable exceptions of less F V, vWF, and ADAMTS-13 in SDP. Cytokine concentrations (TNFα, IL-8, and IL-10) were significantly higher in FFP. The clinical relevance of these findings needs to be established in outcome studies.


Subject(s)
Blood Coagulation Factors/analysis , Cytokines/blood , Detergents/pharmacology , Plasma/drug effects , Solvents/pharmacology , Hemostasis , Humans , Plasma/chemistry , Reference Values
8.
J Thromb Haemost ; 8(6): 1230-4, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20175871

ABSTRACT

BACKGROUND: The adequacy of thromboprophylaxis prescriptions in acutely ill hospitalized medical patients needs improvement. OBJECTIVE: To prospectively assess the efficacy of thromboprophylaxis adequacy of various clinical decision support systems (CDSS) with the aim of increasing the use of explicit criteria for thromboprophylaxis prescription in nine Swiss medical services. METHODS: We randomly assigned medical services to a pocket digital assistant program (PDA), pocket cards (PC) and no CDSS (controls). In centers using an electronic chart, an e-alert system (eAlerts) was developed. After 4 months, we compared post-CDSS with baseline thromboprophylaxis adequacy for the various CDSS and control groups. RESULTS: Overall, 1085 patients were included (395 controls, 196 PC, 168 PDA, 326 eAlerts), 651 pre- and 434 post-CDSS implementation: 472 (43.5%) presented a risk of VTE justifying thromboprophylaxis (31.8% pre, 61.1% post) and 556 (51.2%) received thromboprophylaxis (54.2% pre, 46.8% post). The overall adequacy (% patients with adequate prescription) of pre- and post-CDSS implementation was 56.2 and 50.7 for controls (P = 0.29), 67.3 and 45.3 for PC (P = 0.002), 66.0 and 64.9 for PDA (P = 0.99), 50.5 and 56.2 for eAlerts (P = 0.37), respectively, eAlerts limited overprescription (56% pre, 31% post, P = 0.01). CONCLUSION: While pocket cards and handhelds did not improve thromboprophylaxis adequacy, eAlerts had a modest effect, particularly on the reduction of overprescription. This effect only partially contributes to the improvement of patient safety and more work is needed towards institution-tailored tools.


Subject(s)
Decision Support Systems, Clinical , Venous Thromboembolism/prevention & control , Acute Disease , Aged , Humans
10.
Eur J Appl Physiol ; 105(5): 771-8, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19125285

ABSTRACT

The aim of this study was to investigate possible pathomechanisms behind the cardiovascular morbidity caused by inhalation of particulate matter (PM(10)). For that purpose, healthy volunteers were exposed to high PM(10) concentrations during a 2 h hay storing activity. Blood was drawn in the evening before and after PM(10) exposure and in the morning and evening of the day after exposure. The leukocyte count increased after PM(10) exposure with an initial increase of segmented neutrophils followed by banded forms. C-reactive protein increased over time. Fibrinogen and plasma viscosity became increased in the evening of the day after PM(10) exposure. Platelet aggregation was increased in the evening after PM(10) exposure. At the same time von Willebrand factor and factor VIII were increased, reflecting endothelial activation. These results confirm that acute inhalative exposure to high PM(10) concentrations during hay storage activity leads to a systemic inflammatory reaction, endothelial activation, and platelet aggregation.


Subject(s)
Air Pollutants/toxicity , Inflammation/chemically induced , Particulate Matter/toxicity , Platelet Aggregation/drug effects , Adult , C-Reactive Protein/metabolism , Endothelium, Vascular/metabolism , Endothelium, Vascular/pathology , Female , Humans , Inflammation/metabolism , Male , Middle Aged , von Willebrand Factor/metabolism
11.
J Thromb Haemost ; 4(12): 2704-9, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17010150

ABSTRACT

BACKGROUND: Sphingolipids are signaling molecules in a range of biological processes. While sphingosine-1-phosphate (S1P) is thought to be abundantly stored in platelets and released upon stimulation, knowledge about the distribution and function of other sphingolipids in blood is lacking. OBJECTIVES: To analyze the sphingolipid content of blood components with special emphasis on dynamic changes in platelets. METHODS: Blood components from mice and humans were prepared by gradient centrifugation and analyzed by liquid chromatography-mass spectrometry. Additionally, murine platelets were activated in vitro and in vivo. RESULTS: Isolated non-activated platelets of mice were devoid of S1P, but instead contained dihydrosphingosine-1-phosphate (dhS1P), along with a high concentration of ceramide. Activation of platelets in vitro led to a loss of dhS1P and an increase in sphingosine, accompanied by a reduction of ceramide content. Platelet activation in vivo led to an immediate and continuous rise of dhS1P in plasma, while S1P remained stable. The sphingolipid distribution of human blood was markedly different from mice. Human platelets contained dhS1P in addition to S1P. CONCLUSIONS: Mouse platelets contain dhS1P instead of S1P. Platelet activation causes loss of dhS1P and breakdown of ceramide, implying ceramidase activation. Release of dhS1P from activated platelets might be a novel signaling pathway. Finally, the sphingolipid composition of mouse and human blood shows large differences, which must be considered when studying sphingolipid biology.


Subject(s)
Blood Platelets/metabolism , Platelet Activation , Sphingolipids/blood , Animals , Antibodies , Blood Platelets/drug effects , Blood Platelets/immunology , Cell Separation , Ceramides/blood , Chromatography, Liquid , Erythrocytes/chemistry , Flow Cytometry , Humans , In Vitro Techniques , Leukocytes/chemistry , Lysophospholipids/blood , Mice , Mice, Inbred BALB C , Platelet Activation/drug effects , Platelet Activation/immunology , Platelet Membrane Glycoprotein IIb/immunology , Species Specificity , Spectrometry, Mass, Electrospray Ionization , Sphingolipids/metabolism , Sphingosine/analogs & derivatives , Sphingosine/blood , Thrombin/pharmacology
12.
Ther Umsch ; 56(9): 509-12, 1999 Sep.
Article in German | MEDLINE | ID: mdl-10517121

ABSTRACT

By virtue of a severely prolonged aPTT with a normal thromboplastin time (prothrombin time) and a normal thrombin time, severe FXII deficiency has been diagnosed in a woman without a bleeding diathesis or a history of thromboembolic complications. A deficiency of a factor of the contact activation system (FXII, prekallikrein, high molecular weight kininogen) is usually diagnosed during routine coagulation tests demonstrating a prolonged aPTT. The severe and partial deficiency of FXII, of prekallikrein or high molecular weight kininogen is not associated with a bleeding tendency. In contrast, severely factor XI deficient subjects may suffer from a mild hemorrhagic diathesis, whereas FVIII deficiency (hemophilia A, autoimmune "hemophilia", von Willebrand disease) and FIX deficiency (hemophilia B) are associated with a bleeding tendency of varying severity, depending on the clotting activity of FVIII or FIX, respectively. An isolated prolongation of the aPTT due to a lupus anticoagulant, however, is frequently associated with arterial and/or venous thrombosis. Therefore, in case of a prolongation of the aPTT, its cause has to be determined.


Subject(s)
Factor XII Deficiency/genetics , Hemorrhagic Disorders/genetics , Partial Thromboplastin Time , Adult , Diagnosis, Differential , Factor XII Deficiency/blood , Factor XII Deficiency/diagnosis , Female , Hemorrhagic Disorders/blood , Hemorrhagic Disorders/diagnosis , Humans , Prothrombin Time
13.
Thyroid ; 9(2): 119-25, 1999 Feb.
Article in English | MEDLINE | ID: mdl-10090310

ABSTRACT

The various isoforms of transforming growth factor-beta (TGFbeta) are growth-inhibiting cytokines for cells of epithelial origin. In malignant thyroid tumors, several studies documented a high expression of TGFbeta in the majority of thyroid follicular cells suggesting a possible role as an inhibitor of cell proliferation. In contrast to this uniform pattern of TGFbeta expression in thyroid cancer, scarce and controversial data have been reported on the expression of TGFbeta in benign multinodular goiter. In the present study, we therefore analyzed the expression of TGFbeta1, TGFbeta2, and TGFbeta3 in normal thyroid tissue, multinodular goiters and papillary thyroid carcinomas by immunohistochemistry. In normal thyroid tissue, expression of the 3 TGFbeta isoforms was barely detectable. However, in the carcinomas, almost all epithelial cells displayed immunoreactivity for the three TGFbeta isoforms. In the nodules from multinodular goiters, all 3 isoforms were found to be expressed although the immunolocalization of the 3 proteins was highly variable. TGFbeta-immunostaining was found in scattered clusters of variable size and, its expression pattern was heterogenous among individual cells within single follicles. TGFbeta-positivity was present in spite of immunostaining for proliferating cell nuclear antigen (PCNA), a marker for actively proliferating cells. In conclusion, this study shows that thyroid carcinomas and benign tumors express the TGFbeta1, TGFbeta2, and TGFbeta3 isoforms. In contrast to the abundant and homogeneous expression in differentiated thyroid carcinomas, TGFbeta expression displays a highly variable interfollicular and intrafollicular pattern in multinodular goiters, suggesting an important role of TGFbeta isoforms in tumorigenesis of thyroid cells.


Subject(s)
Carcinoma/metabolism , Gene Expression , Goiter, Nodular/metabolism , Thyroid Neoplasms/metabolism , Transforming Growth Factor beta/genetics , Adenocarcinoma, Follicular/metabolism , Carcinoma, Papillary/metabolism , Immunohistochemistry , Proliferating Cell Nuclear Antigen/analysis , Transforming Growth Factor beta/analysis
14.
J Endocrinol ; 149(3): 485-96, 1996 Jun.
Article in English | MEDLINE | ID: mdl-8691107

ABSTRACT

While the multifunctional proteins of the transforming growth factor-beta (TGF-beta) family have a potent antiproliferative effect on thyroid follicular cell growth, increased expression of TGF-beta in proliferating thyroid cells and in thyroid tumours has recently been described, suggesting a secondary counter-regulatory role of these proteins. We have studied further this apparent paradox in vitro using FRTL-5 cells, 5 continuous cell strains from feline multinodular goitres (MNG) and 29 primary cultures prepared from human MNG. While dose dependent inhibition of FRTL-5 cell growth was confirmed, a variable fraction of these cells was naturally resistant towards TGF-beta 1, thus explaining the large interassay variability of growth inhibition (36 to 98% within 2 days, n = 19). After 40 days of continuous exposure, FRTL-5 cells became fully refractory towards TGF-beta 1 inhibition, due to the selective growth of naturally resistant subclones, as demonstrated for example by microscopic observation of three-dimensionally growing collagen-embedded cell clusters. The refractoriness could still be demonstrated even after several cell passages. In addition, 2 out of 5 feline thyroid cell strains obtained from feline MNG and 18 out of 29 primary cultures from human MNG showed a high degree of refractoriness towards TGF-beta. We conclude that constitutively TGF-beta resistant cells may occur in thyroid glands and that persistent TGF-beta refractoriness may secondarily be acquired. Resistant cells may escape regular growth control mechanisms and hence may contribute to the notorious heterogeneity of thyroid growth and to nodular transformation.


Subject(s)
Thyroid Gland/growth & development , Transforming Growth Factor beta/pharmacology , Animals , Cats , Cell Division/drug effects , Cell Line , Clone Cells , Depression, Chemical , Dose-Response Relationship, Drug , Drug Resistance , Goiter/pathology , Humans , Immunohistochemistry , Keratins/analysis , Thyroglobulin/analysis , Thyroid Gland/chemistry , Thyroid Gland/drug effects , Time Factors , Tumor Cells, Cultured
15.
J Endocrinol ; 145(3): 513-20, 1995 Jun.
Article in English | MEDLINE | ID: mdl-7636435

ABSTRACT

In accordance with the available data most authors conclude that epidermal growth factor (EGF) has very little or no effect on FRTL-5 cells. This has been viewed as a serious handicap of this cell line. In the present study we cultivated three strains of FRTL-5 cells from different sources and assessed their response to EGF with regard to proliferation, function and differentiation. Cell proliferation was assessed by counting in a Coulter cell counter after culturing cells at suboptimal conditions in well plates. Cell function was studied by measuring iodide uptake. Cell differentiation was examined immunocytochemically by staining monolayer cultures for thyroglobulin (Tg) and EGF receptor (EGFr) as well as morphologically by microscopical evaluation of monolayer cultures. All three FRTL-5 cell lines investigated express EGFr. In two wild type FRTL-5 cell lines EGF stimulates growth, an effect that is enhanced by the presence of TSH, and partially inhibits iodide uptake. A third mutated strain of FRTL-5 cells does not respond to EGF. Tg expression can be demonstrated immunocytochemically in EGF-treated cells as well as in controls. Morphologically, in monolayer culture EGF-treated cells cannot be distinguished from controls. Contrary to previous reports, these studies demonstrate EGF effects on FRTL-5 cells that are consistent with EGF effects established in other thyroid follicular cells.


Subject(s)
Epidermal Growth Factor/pharmacology , Thyroid Gland/drug effects , Animals , Cell Division/drug effects , Cell Line , Immunohistochemistry , Iodides/metabolism , Rats , Rats, Inbred F344 , Stimulation, Chemical , Thyroid Gland/cytology , Thyroid Gland/metabolism
16.
Thyroidology ; 3(3): 115-8, 1991 Dec.
Article in English | MEDLINE | ID: mdl-1726925

ABSTRACT

Thyroid cell lines have contributed a lot to the understanding of goitrogenesis. The cell lines mostly used in thyroid research are briefly discussed, namely the rat thyroid cell lines FRTL and FRTL-5, the porcine thyroid cell lines PORTHOS and ARTHOS, The sheep thyroid cell lines OVNIS 5H and 6H, the cat thyroid cell lines PETCAT 1 to 4 and ROMCAT, and the human thyroid cell lines FTC-133 and HTh 74. Chinese hamster ovary (CHO) cells and COS-7 cells, stably transfected with TSH receptor cDNA and expressing a functional TSH receptor, are discussed as examples for non-thyroidal cells, transfected with thyroid genes.


Subject(s)
Goiter , Animals , Cell Line , Goiter/pathology , Goiter/physiopathology , Humans , Receptors, Thyrotropin/genetics , Transfection