Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Med Imaging ; 24(1): 23, 2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38267889

ABSTRACT

BACKGROUND: Brain CT can be used to evaluate pediatric patients with suspicion of cerebral pathology when anesthetic and MRI resources are scarce. This study aimed to assess if pediatric patients referred for an elective brain CT could endure a diagnostic fast brain MRI without general anesthesia using a one-minute multi-contrast EPI-based sequence (EPIMix) with comparable diagnostic performance. METHODS: Pediatric patients referred for an elective brain CT between March 2019 and March 2020 were prospectively included and underwent EPIMix without general anesthesia in addition to CT. Three readers (R1-3) independently evaluated EPIMix and CT images on two separate occasions. The two main study outcomes were the tolerance to undergo an EPIMix scan without general anesthesia and its performance to classify a scan as normal or abnormal. Secondary outcomes were assessment of disease category, incidental findings, diagnostic image quality, diagnostic confidence, and image artifacts. Further, a side-by-side evaluation of EPIMix and CT was performed. The signal-to-noise ratio (SNR) was calculated for EPIMix on T1-weighted, T2-weighted, and ADC images. Descriptive statistics, Fisher's exact test, and Chi-squared test were used to compare the two imaging modalities. RESULTS: EPIMix was well tolerated by all included patients (n = 15) aged 5-16 (mean 11, SD 3) years old. Thirteen cases on EPIMix and twelve cases on CT were classified as normal by all readers (R1-3), while two cases on EPIMix and three cases on CT were classified as abnormal by one reader (R1), (R1-3, p = 1.00). There was no evidence of a difference in diagnostic confidence, image quality, or the presence of motion artifacts between EPIMix and CT (R1-3, p ≥ 0.10). Side-by-side evaluation (R2 + R4 + R5) reviewed all scans as lacking significant pathological findings on EPIMix and CT images. CONCLUSIONS: Full brain MRI-based EPIMix sequence was well tolerated without general anesthesia with a diagnostic performance comparable to CT in elective pediatric patients. TRIAL REGISTRATION: This study was approved by the Swedish Ethical Review Authority (ethical approval number/ID Ethical approval 2017/2424-31/1). This study was a clinical trial study, with study protocol published at ClinicalTrials.gov with Trial registration number NCT03847051, date of registration 18/02/2019.


Subject(s)
Brain , Magnetic Resonance Imaging , Child , Child, Preschool , Humans , Brain/diagnostic imaging , Feasibility Studies , Prospective Studies , Tomography, X-Ray Computed
2.
Radiology ; 297(3): E324-E334, 2020 12.
Article in English | MEDLINE | ID: mdl-32729812

ABSTRACT

Background Neurologic complications in coronavirus disease 2019 (COVID-19) have been described, but the understanding of their pathophysiologic causes and neuroanatomical correlates remains limited. Purpose To report on the frequency and type of neuroradiological findings in COVID-19. Materials and Methods In this retrospective study, all consecutive adult hospitalized patients with polymerase chain reaction positivity for severe acute respiratory syndrome coronavirus 2 and who underwent neuroimaging at Karolinska University Hospital between March 2 and May 24, 2020, were included. All examinations were systematically re-evaluated by 12 readers. Summary descriptive statistics were calculated. Results A total of 185 patients with COVID-19 (62 years ± 14 [standard deviation]; 138 men) underwent neuroimaging. In total, 222 brain CT, 47 brain MRI, and seven spinal MRI examinations were performed. Intra-axial susceptibility abnormalities were the most common finding (29 of 39; 74%, 95% CI: 58, 87) in patients who underwent brain MRI, often with an ovoid shape suggestive of microvascular pathology and with a predilection for the corpus callosum (23 of 39; 59%; 95% CI: 42, 74) and juxtacortical areas (14 of 39; 36%; 95% CI: 21, 53). Ischemic and macrohemorrhagic manifestations were also observed, but vascular imaging did not demonstrate overt abnormalities. Dynamic susceptibility contrast perfusion MRI in 19 patients did not reveal consistent asymmetries between hemispheres or regions. Many patients (18 of 41; 44%; 95% CI: 28, 60) had leukoencephalopathy and one patient had a cytotoxic lesion of the corpus callosum. Other findings included olfactory bulb signal abnormalities (seven of 37; 19%), prominent optic nerve subarachnoid spaces (20 of 36; 56%), and enhancement of the parenchyma (three of 20; 15%), leptomeninges (three of 20; 15%), cranial nerves (two of 20; 10%), and spinal nerves (two of four; 50%). At MRI follow-up, regression of leukoencephalopathy and progressive leptomeningeal enhancement was observed in one patient each, respectively, which is suggestive of dynamic processes. Conclusion Patients with coronavirus disease 2019 had a wide spectrum of vascular and inflammatory involvement of both the central and peripheral nervous system. © RSNA, 2020 Online supplemental material is available for this article.


Subject(s)
Coronavirus Infections/complications , Magnetic Resonance Imaging/methods , Nervous System Diseases/complications , Nervous System Diseases/diagnostic imaging , Neuroimaging/methods , Pneumonia, Viral/complications , Tomography, X-Ray Computed/methods , Betacoronavirus , Brain/diagnostic imaging , COVID-19 , Cohort Studies , Humans , Pandemics , Retrospective Studies , SARS-CoV-2 , Spine/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...