Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Photoacoustics ; 25: 100318, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34888139

ABSTRACT

We report on the realization, calibration, and test outdoor of a 19-inches rack 3-units sized Quartz Enhanced Photoacoustic Spectroscopy (QEPAS) trace gas sensor designed for real-time carbon monoxide monitoring in ambient air. Since CO acts as a slow energy relaxer when excited in the mid-infrared spectral region, its QEPAS signal is affected by the presence of relaxation promoters, such as water vapor, or quenchers like molecular oxygen. We analyzed in detail all the CO relaxation processes with typical collisional partners in an ambient air matrix and used this information to evaluate oxygen and humidity-related effects, allowing the real CO concentration to be retrieved. The sensor was tested outdoor in a trafficked urban area for several hours providing results comparable with the daily averages reported by the local air inspection agency, with spikes in CO concentration correlated to the passages of heavy-duty vehicles.

2.
Molecules ; 25(23)2020 Nov 28.
Article in English | MEDLINE | ID: mdl-33260601

ABSTRACT

We report on a fiber-coupled, quartz-enhanced photoacoustic spectroscopy (QEPAS) near-IR sensor for sequential detection of methane (CH4 or C1) and ethane (C2H6 or C2) in air. With the aim of developing a lightweight, compact, low-power-consumption sensor suitable for unmanned aerial vehicles (UAVs)-empowered environmental monitoring, an all-fiber configuration was designed and realized. Two laser diodes emitting at 1653.7 nm and 1684 nm for CH4 and C2H6 detection, respectively, were fiber-combined and fiber-coupled to the collimator port of the acoustic detection module. No cross talk between methane and ethane QEPAS signal was observed, and the related peak signals were well resolved. The QEPAS sensor was calibrated using gas samples generated from certified concentrations of 1% CH4 in N2 and 1% C2H6 in N2. At a lock-in integration time of 100 ms, minimum detection limits of 0.76 ppm and 34 ppm for methane and ethane were achieved, respectively. The relaxation rate of CH4 in standard air has been investigated considering the effects of H2O, N2 and O2 molecules. No influence on the CH4 QEPAS signal is expected when the water vapor concentration level present in air varies in the range 0.6-3%.


Subject(s)
Environmental Monitoring/methods , Ethane/analysis , Methane/analysis , Photoacoustic Techniques/methods , Quartz/chemistry , Spectroscopy, Near-Infrared/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...