1.
Sensors (Basel) ; 23(6)2023 Mar 20.
Article in English | MEDLINE | ID: mdl-36991992

ABSTRACT

BACKGROUND: This article presents the system architecture and validation of the NeuroSuitUp body-machine interface (BMI). The platform consists of wearable robotics jacket and gloves in combination with a serious game application for self-paced neurorehabilitation in spinal cord injury and chronic stroke. METHODS: The wearable robotics implement a sensor layer, to approximate kinematic chain segment orientation, and an actuation layer. Sensors consist of commercial magnetic, angular rate and gravity (MARG), surface electromyography (sEMG), and flex sensors, while actuation is achieved through electrical muscle stimulation (EMS) and pneumatic actuators. On-board electronics connect to a Robot Operating System environment-based parser/controller and to a Unity-based live avatar representation game. BMI subsystems validation was performed using exercises through a Stereoscopic camera Computer Vision approach for the jacket and through multiple grip activities for the glove. Ten healthy subjects participated in system validation trials, performing three arm and three hand exercises (each 10 motor task trials) and completing user experience questionnaires. RESULTS: Acceptable correlation was observed in 23/30 arm exercises performed with the jacket. No significant differences in glove sensor data during actuation state were observed. No difficulty to use, discomfort, or negative robotics perception were reported. CONCLUSIONS: Subsequent design improvements will implement additional absolute orientation sensors, MARG/EMG based biofeedback to the game, improved immersion through Augmented Reality and improvements towards system robustness.


Subject(s)
Exoskeleton Device , Neurological Rehabilitation , Robotics , Stroke Rehabilitation , Stroke , Wearable Electronic Devices , Humans
2.
JMIR Res Protoc ; 11(9): e41152, 2022 Sep 13.
Article in English | MEDLINE | ID: mdl-36099009

ABSTRACT

BACKGROUND: Spinal cord injury (SCI) constitutes a major sociomedical problem, impacting approximately 0.32-0.64 million people each year worldwide; particularly, it impacts young individuals, causing long-term, often irreversible disability. While effective rehabilitation of patients with SCI remains a significant challenge, novel neural engineering technologies have emerged to target and promote dormant neuroplasticity in the central nervous system. OBJECTIVE: This study aims to develop, pilot test, and optimize a platform based on multiple immersive man-machine interfaces offering rich feedback, including (1) visual motor imagery training under high-density electroencephalographic recording, (2) mountable robotic arms controlled with a wireless brain-computer interface (BCI), (3) a body-machine interface (BMI) consisting of wearable robotics jacket and gloves in combination with a serious game (SG) application, and (4) an augmented reality module. The platform will be used to validate a self-paced neurorehabilitation intervention and to study cortical activity in chronic complete and incomplete SCI at the cervical spine. METHODS: A 3-phase pilot study (clinical trial) was designed to evaluate the NeuroSuitUp platform, including patients with chronic cervical SCI with complete and incomplete injury aged over 14 years and age-/sex-matched healthy participants. Outcome measures include BCI control and performance in the BMI-SG module, as well as improvement of functional independence, while also monitoring neuropsychological parameters such as kinesthetic imagery, motivation, self-esteem, depression and anxiety, mental effort, discomfort, and perception of robotics. Participant enrollment into the main clinical trial is estimated to begin in January 2023 and end by December 2023. RESULTS: A preliminary analysis of collected data during pilot testing of BMI-SG by healthy participants showed that the platform was easy to use, caused no discomfort, and the robotics were perceived positively by the participants. Analysis of results from the main clinical trial will begin as recruitment progresses and findings from the complete analysis of results are expected in early 2024. CONCLUSIONS: Chronic SCI is characterized by irreversible disability impacting functional independence. NeuroSuitUp could provide a valuable complementary platform for training in immersive rehabilitation methods to promote dormant neural plasticity. TRIAL REGISTRATION: ClinicalTrials.gov NCT05465486; https://clinicaltrials.gov/ct2/show/NCT05465486. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/41152.

3.
Sensors (Basel) ; 21(6)2021 Mar 16.
Article in English | MEDLINE | ID: mdl-33809721

ABSTRACT

Recent advances in the field of neural rehabilitation, facilitated through technological innovation and improved neurophysiological knowledge of impaired motor control, have opened up new research directions. Such advances increase the relevance of existing interventions, as well as allow novel methodologies and technological synergies. New approaches attempt to partially overcome long-term disability caused by spinal cord injury, using either invasive bridging technologies or noninvasive human-machine interfaces. Muscular dystrophies benefit from electromyography and novel sensors that shed light on underlying neuromotor mechanisms in people with Duchenne. Novel wearable robotics devices are being tailored to specific patient populations, such as traumatic brain injury, stroke, and amputated individuals. In addition, developments in robot-assisted rehabilitation may enhance motor learning and generate movement repetitions by decoding the brain activity of patients during therapy. This is further facilitated by artificial intelligence algorithms coupled with faster electronics. The practical impact of integrating such technologies with neural rehabilitation treatment can be substantial. They can potentially empower nontechnically trained individuals-namely, family members and professional carers-to alter the programming of neural rehabilitation robotic setups, to actively get involved and intervene promptly at the point of care. This narrative review considers existing and emerging neural rehabilitation technologies through the perspective of replacing or restoring functions, enhancing, or improving natural neural output, as well as promoting or recruiting dormant neuroplasticity. Upon conclusion, we discuss the future directions for neural rehabilitation research, diagnosis, and treatment based on the discussed technologies and their major roadblocks. This future may eventually become possible through technological evolution and convergence of mutually beneficial technologies to create hybrid solutions.


Subject(s)
Robotics , Spinal Cord Injuries , Stroke Rehabilitation , Stroke , Artificial Intelligence , Electromyography , Humans
4.
Biomed Res Int ; 2017: 5708937, 2017.
Article in English | MEDLINE | ID: mdl-28948168

ABSTRACT

Advances in neural interfaces have demonstrated remarkable results in the direction of replacing and restoring lost sensorimotor function in human patients. Noninvasive brain-computer interfaces (BCIs) are popular due to considerable advantages including simplicity, safety, and low cost, while recent advances aim at improving past technological and neurophysiological limitations. Taking into account the neurophysiological alterations of disabled individuals, investigating brain connectivity features for implementation of BCI control holds special importance. Off-the-shelf BCI systems are based on fast, reproducible detection of mental activity and can be implemented in neurorobotic applications. Moreover, social Human-Robot Interaction (HRI) is increasingly important in rehabilitation robotics development. In this paper, we present our progress and goals towards developing off-the-shelf BCI-controlled anthropomorphic robotic arms for assistive technologies and rehabilitation applications. We account for robotics development, BCI implementation, and qualitative assessment of HRI characteristics of the system. Furthermore, we present two illustrative experimental applications of the BCI-controlled arms, a study of motor imagery modalities on healthy individuals' BCI performance, and a pilot investigation on spinal cord injured patients' BCI control and brain connectivity. We discuss strengths and limitations of our design and propose further steps on development and neurophysiological study, including implementation of connectivity features as BCI modality.


Subject(s)
Artificial Limbs , Brain-Computer Interfaces , Prosthesis Design , Rehabilitation , Robotics/methods , Humans , Rehabilitation/instrumentation , Rehabilitation/methods
5.
Article in English | MEDLINE | ID: mdl-19163902

ABSTRACT

A flexible, scaleable and cost-effective medical telemetry system is described for monitoring sleep-related disorders in the home environment. The system was designed and built for real-time data acquisition and processing, allowing for additional use in intensive care unit scenarios where rapid medical response is required in case of emergency. It comprises a wearable body area network of Zigbee-compatible wireless sensors worn by the subject, a central database repository residing in the medical centre and thin client workstations located at the subject's home and in the clinician's office. The system supports heterogeneous setup configurations, involving a variety of data acquisition sensors to suit several medical applications. All telemetry data is securely transferred and stored in the central database under the clinicians' ownership and control.


Subject(s)
Monitoring, Ambulatory/instrumentation , Polysomnography/instrumentation , Remote Consultation/instrumentation , Sleep/physiology , Telemetry/instrumentation , Transducers , Diagnosis, Computer-Assisted/instrumentation , Diagnosis, Computer-Assisted/methods , Equipment Design , Equipment Failure Analysis , Equipment and Supplies , Humans , Monitoring, Ambulatory/methods , Polysomnography/methods , Remote Consultation/methods , Reproducibility of Results , Sensitivity and Specificity , Systems Integration , Telemetry/methods , User-Computer Interface
6.
IEEE Trans Biomed Eng ; 51(3): 525-35, 2004 Mar.
Article in English | MEDLINE | ID: mdl-15000383

ABSTRACT

A novel microelectronic "pill" has been developed for in situ studies of the gastro-intestinal tract, combining microsensors and integrated circuits with system-level integration technology. The measurement parameters include real-time remote recording of temperature, pH, conductivity, and dissolved oxygen. The unit comprises an outer biocompatible capsule encasing four microsensors, a control chip, a discrete component radio transmitter, and two silver oxide cells (the latter providing an operating time of 40 h at the rated power consumption of 12.1 mW). The sensors were fabricated on two separate silicon chips located at the front end of the capsule. The robust nature of the pill makes it adaptable for use in a variety of environments related to biomedical and industrial applications.


Subject(s)
Biosensing Techniques/instrumentation , Electronics, Medical/instrumentation , Equipment Failure Analysis , Miniaturization/methods , Monitoring, Ambulatory/instrumentation , Monitoring, Ambulatory/methods , Telemetry/instrumentation , Transducers , Biomedical Engineering/instrumentation , Biomedical Engineering/methods , Biosensing Techniques/methods , Coated Materials, Biocompatible , Diagnosis, Computer-Assisted/instrumentation , Diagnosis, Computer-Assisted/methods , Electrodes, Implanted , Electronics, Medical/methods , Equipment Design , Hydrogen-Ion Concentration , Oxygen/analysis , Prostheses and Implants , Systems Integration , Telemetry/methods , Thermography/instrumentation , Thermography/methods
SELECTION OF CITATIONS