Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Transplant Proc ; 43(10): 4032-5, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22172896

ABSTRACT

This case study describes a patient who developed peanut allergy following lung transplantation. A 54-year-old woman underwent bilateral lung transplantation on June 2009 owing to severe chronic obstructive pulmonary disease. She had no history of food allergy before transplantation. The donor, however, was a 20-year-old man who was fatally injured during an automobile accident; he was allergic to peanuts. At 3 months after transplantation, the lung recipient presented with acute dyspnea and urticaria 15 minutes after consuming food containing peanut derivatives. Pre- and posttransplantation recipient blood samples analyzed for the presence of IgE antibodies specific for peanut allergens confirmed that the allergy had been passively transfered as a consequence of transplantation. Food allergy following solid organ transplantation is thought to be rare, mostly occurring in children. Two mechanisms may explain the observations described for the patient reported in this study: de novo development of peanut allergies after transplantation, or passive transfer of peanut allergies from a peanut-sensitized organ donor. This case report documenting pre- and posttransplantation IgE status in a lung transplantation case suggested that the allergic status of organ donors should be thoroughly assessed before transplantation, and potential allergy transfer risks must be discussed with the transplant team and the patient.


Subject(s)
Lung Transplantation/adverse effects , Peanut Hypersensitivity/etiology , Pulmonary Disease, Chronic Obstructive/surgery , Tissue Donors , Female , Humans , Immunoglobulin E/blood , Intradermal Tests , Male , Middle Aged , Peanut Hypersensitivity/diagnosis , Peanut Hypersensitivity/immunology , Treatment Outcome , Young Adult
2.
Arch Mal Coeur Vaiss ; 84(1): 27-32, 1991 Jan.
Article in French | MEDLINE | ID: mdl-2012482

ABSTRACT

Doppler echocardiography has become the method of choice for the evaluation of cardiac valve prostheses. In order to determine the reproducibility of the measurements of pressure gradient and valve surface area, 55 patients with aortic valve prostheses without clinical dysfunction and having at most a trivial regurgitation on color Doppler examination underwent a double evaluation during an average interval of 9 +/- 5 months. The maximum and mean pressure gradients were recorded and the valve surface area calculated using the continuity equation in all cases. The subaortic diameter was taken to be constant and equal to the external diameter of the prosthesis. No significant differences were found between the two evaluations of mean pressure gradient and valve surface area. The intra-patient variability was +/- 8 mmHg for the maximum pressure gradient, +/- 6 mmHg for the mean pressure gradient, +/- 0.33 cm2 for valve surface area calculated using the maximum velocities and +/- 0.44 cm2 when the velocity-time integrals were used. When expressed as a percentage, the mean coefficient of variation was 21 +/- 17% for the maximum pressure gradient, 21 +/- 18% for the mean pressure gradients, 21 +/- 15% for the valve surface area calculated using the maximum velocities and 22 +/- 14% when the ratio of velocity-time integrals was used.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Echocardiography, Doppler , Heart Valve Prosthesis , Adult , Aged , Aged, 80 and over , Analysis of Variance , Aortic Valve , Blood Flow Velocity , Blood Pressure , Female , Humans , Male , Middle Aged , Postoperative Period , Prosthesis Failure , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...