Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(13)2023 Jun 30.
Article in English | MEDLINE | ID: mdl-37447899

ABSTRACT

The rapid evolution of wireless communication technologies (such as fifth-generation (5G) cellular networks) in the last years has allowed connecting different objects (from wearable electronics to vehicles) and people through communication networks, and at the same time, has led to widespread deployment of base stations. Along with this growth, questions about the potential adverse effects on human health due to electromagnetic fields (EMFs) from base station antennas have also been raised. In this paper, we focus on the assessment of EMFs in automobiles during short (between cities) and long (between countries) trips on several European roads. Comprehensive measurement campaigns were carried out in several European countries: Austria, Bulgaria, Croatia, Hungary, Italy, Slovenia, and the Republic of Serbia. The results show that the median total electric field is 0.23-0.24 V/m in Bulgaria, Croatia, Hungary, Italy, and the Republic of Serbia. In Austria and Slovenia, the median is 0.28-0.31 V/m. Austria demonstrated the highest value for the total electric field, at 17.4 V/m.


Subject(s)
Electromagnetic Fields , Environmental Exposure , Humans , Europe , Croatia , Cities , Radio Waves
2.
Micromachines (Basel) ; 14(3)2023 Feb 23.
Article in English | MEDLINE | ID: mdl-36984921

ABSTRACT

The last few years have seen a rapid increase in body-worn devices because these devices cover a broad spectrum of potential uses. Moreover, body-worn devices still require improvements in their flexibility, size, and weight that necessitate the development of flexible and miniature antennas. In this paper, we present a new flexible miniature antenna for body-worn devices. To ensure flexibility and comfort when the antenna is in contact with the human body, a substrate from natural rubber filled with TiO2 is developed. The miniaturization is achieved using the quadratic Koch curve. The antenna design, optimization, and characterization are performed on a human body model. The performance of the antenna is analyzed in two scenarios: (1) in- to on-body, and (2) on- to off-body wireless communications. The results show that the antenna realized the maximum telemetry range of more than 80 mm for in-body communications and more than 2 m for off-body communications. Moreover, the highest 10 g specific absorption rate value was 0.62 W/kg. These results, in addition to the antenna's compact dimensions (12 mm × 26 mm × 2.5 mm) and the low manufacturing price, make the proposed antenna an ideal candidate for health telemetry applications.

3.
Sensors (Basel) ; 22(14)2022 Jul 08.
Article in English | MEDLINE | ID: mdl-35890818

ABSTRACT

In recent years, there has been a rapid development in the wearable industry. The growing number of wearables has led to the demand for new lightweight, flexible wearable antennas. In order to be applicable in IoT wearable devices, the antennas must meet certain electrical, mechanical, manufacturing, and safety requirements (e.g., specific absorption rate (SAR) below worldwide limits). However, the assessment of SAR does not provide information on the mechanisms of interaction between low-intensity electromagnetic fields emitted by wearable antennas and the human body. In this paper, we presented a detailed investigation of the SAR induced in erythrocyte suspensions from a fully textile wearable antenna at realistic (net input power 6.3 mW) and conservative (net input power 450 mW) conditions at 2.41 GHz, as well as results from in vitro experiments on the stability of human erythrocyte membranes at both exposure conditions. The detailed investigation showed that the 1 g average SARs were 0.5758 W/kg and 41.13 W/kg, respectively. Results from the in vitro experiments demonstrated that the short-term (20 min) irradiation of erythrocyte membranes in the reactive near-field of the wearable antenna at 6.3 mW input power had a stabilizing effect. Long-term exposure (120 min) had a destabilizing effect on the erythrocyte membrane.


Subject(s)
Electromagnetic Fields , Wearable Electronic Devices , Humans
4.
Sensors (Basel) ; 22(12)2022 Jun 15.
Article in English | MEDLINE | ID: mdl-35746298

ABSTRACT

In recent years, the interest in the Internet of Things (IoT) has been growing because this technology bridges the gap between the physical and virtual world, by connecting different objects and people through communication networks, in order to improve the quality of life. New IoT wearable devices require new types of antennas with unique shapes, made on unconventional substrates, which can be unobtrusively integrated into clothes and accessories. In this paper, we propose a fully textile dual-band logo antenna integrated with a reflector for application in IoT wearable devices. The proposed antenna's radiating elements have been shaped to mimic the logo of South-West University "Neofit Rilski" for an unobtrusive integration in accessories. A reflector has been mounted on the opposite side of the textile substrate to reduce the radiation from the wearable antenna and improve its robustness against the loading effect from nearby objects. Two antenna prototypes were fabricated and tested in free space as well as on three different objects (human body, notebook, and laptop). Moreover, in the two frequency ranges of interest a radiation efficiency of 25-38% and 62-90% was achieved. Moreover, due to the reflector, the maximum local specific-absorption rate, which averaged over 10 g mass in the human-body phantom, was found to be equal to 0.5182 W/kg at 2.4 GHz and 0.16379 W/kg at 5.47 GHz. Additionally, the results from the performed measurement-campaign collecting received the signal-strength indicator and packet loss for an off-body scenario in real-world use, demonstrating that the backpack-integrated antenna prototype can form high-quality off-body communication channels.


Subject(s)
Internet of Things , Wearable Electronic Devices , Equipment Design , Humans , Quality of Life , Textiles , Wireless Technology
5.
Sensors (Basel) ; 20(18)2020 Sep 10.
Article in English | MEDLINE | ID: mdl-32927710

ABSTRACT

The rapid development of wearable wireless sensor networks (W-WSNs) has created high demand for small and flexible antennas. In this paper, we present small, flexible, low-profile, light-weight all-textile antennas for application in W-WSNs and investigate the impact of the textile materials on the antenna performance. A step-by-step procedure for design, fabrication and measurement of small wearable backed antennas for application in W-WSNs is also suggested. Based on the procedure, an antenna on a denim substrate is designed as a benchmark. It demonstrates very small dimensions and a low-profile, all while achieving a bandwidth (|S11| < -6 dB) of 285 MHz from 2.266 to 2.551 GHz, radiation efficiency more than 12% in free space and more than 6% on the phantom. Also, the peak 10 g average SAR is 0.15 W/kg. The performance of the prototype of the proposed antenna was also evaluated using an active test. To investigate the impact of the textile materials on the antenna performance, the antenna geometry was studied on cotton, polyamide-elastane and polyester substrates. It has been observed that the lower the loss tangent of the substrate material, the narrower the bandwidth. Moreover, the higher the loss tangent of the substrate, the lower the radiation efficiency and SAR.


Subject(s)
Electromagnetic Radiation , Textiles , Wearable Electronic Devices , Wireless Technology , Cotton Fiber , Equipment Design , Nylons , Polyesters
6.
Electromagn Biol Med ; 32(2): 218-25, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23675625

ABSTRACT

A new microwave exposure system for biological experiments with well-defined exposure conditions and improved control of the exposure parameters consisting of variable frequency power source, coaxial to waveguide transition, matching network and single-mode resonant cavity with movable shorting plunger was fabricated and characterized. The introduction of a biological sample into a resonant cavity has a large impact on its field configuration and port impedance. As such, the properties, geometry and position of the biological sample become a part of the electrical properties of the microwave circuit. With that change, the electrical properties of the resonant cavity, such as impedance, quality factor and resonant frequency, also change. In this study, an appropriate coupling system with effective power transfer and an algorithm to tuning and coupling of resonant cavity in resonance before and after the introduction of biological sample have been proposed. This procedure will lead to a known dose distribution within the biological sample and allow a better comparison with other studies. Coupling of the electromagnetic energy into a resonant cavity was experimentally investigated. Graphical representation of cavity impedance in case of undercoupled, critically coupled and overcoupled cavity has been presented. Critical coupling of an empty resonant cavity has been accomplished at voltage standing wave ratio (VSWR) 1.01, at resonance frequencies 900 and 947.5 MHz. Critical coupling with the introduction of a biological sample has been accomplished at VSWR ≤ 1.07 for frequency bandwidth 1 MHz and VSWR ≤ 1.5 for frequency bandwidth up to 5 MHz with central frequency 947.5 MHz.


Subject(s)
Microwaves , Radiobiology/methods , Algorithms , Microwaves/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...