Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Eur J Obstet Gynecol Reprod Biol ; 296: 316-320, 2024 May.
Article in English | MEDLINE | ID: mdl-38518486

ABSTRACT

PURPOSE: We aimed to investigate maternal thyroid parenchymal vascularity with 2-dimensional color superb microvascular imaging vascularization index (2D-cSMIVI) levels and thyroid gland volume in the first, second and third trimesters. METHODS: This longitudinal prospective study was carried out with participants selected from 30 healthy asymptomatic pregnant women. Ultrasonography (US) for the thyroid gland was performed in each trimester. The vascularization index (VI) values obtained by manually drawing the contours of the thyroid parenchyma in the longutidinal plane, using the free region of interest (ROI) with 2DcSMIVI mode. VI values obtained in each trimester, thyroid hormone levels (TSH, T3, T4) and thyroid volumes were compared. RESULTS: We have detected that thyroid gland vascularity increased significantly as pregnancy progresses. The mean VI values of thyroid gland in third trimester were significantly higher than first and second trimester (p < 0.001), and the mean VI values of the thyroid gland in the second trimester were significantly higher than first trimester (p < 0.001). During pregnancy, we detected the increase in VI values, TSH levels and thyroid gland volumes. CONCLUSION: Maternal thyroid gland gray scale findings, parenchymal vascularization, thyroid volumes should be evaluated routinely for the healthy fetal development. 2D-cSMIVI method allows us to evaluate vascularization with quantitative numerical values objectively. We have detected that the VI values and volume of the thyroid gland increases as pregnancy progresses. In the complex situation of pregnancy process, the thyroid gland can be evaluated quantitatively with SMI method effectively.


Subject(s)
Thyroid Gland , Ultrasonography, Doppler , Humans , Female , Pregnancy , Thyroid Gland/diagnostic imaging , Prospective Studies , Ultrasonography, Doppler/methods , Thyroid Hormones , Thyrotropin
2.
J Ultrason ; 23(93): e66-e72, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37520746

ABSTRACT

Aim: Our aim was to gain an idea about testicular injury by comparing the reduced volume, which is one of the indirect indicators of testicular damage in undescended testes, and by evaluating the reduced microvascular blood flow by superb microvascular imaging, and also to determine whether superb microvascular imaging modes could detect microvascular blood flow in more detail in the decreased volume of undescended testes. Material and methods: We compared testicular blood flow in undescended testes via conventional Doppler imaging, color superb microvascular imaging, and monochrome superb microvascular imaging techniques with contralateral normally located testis and normal control group. Each sample of testicular tissue was evaluated using a qualitative method. Spot color encoding and linear flow color encoding counts determined in testicular parenchyma were counted separately and expressed as numerical data. The localization of the examined testes in the grayscale was noted (proximal inguinal canal, medial inguinal canal, distal inguinal canal, and scrotal). The volume of undescended testes was calculated automatically via a formula for volume. Results: Monochrome superb microvascular imaging is significantly superior in visualizing the vascularity of undescended testes compared with color Doppler, power Doppler and color superb microvascular imaging (p = 0.001). Also, undescended testes have a significantly lower blood flow compared with contralateral normal testes (p = 0.001). The volume of undescended testes was significantly lower than the contralateral normal testes. Conclusions: The volume, structure and blood flow are indirect signs of testicular damage in undescended testes. Monochrome superb microvascular imaging can detect vascularity in undescended testes better than the conventional Doppler imaging technique and color superb microvascular imaging. Based on our findings, we can report that monochrome superb microvascular imaging can be used to evaluate testicular injury and vascularity of undescended testes.

3.
J Ultrasound ; 25(1): 59-65, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33409864

ABSTRACT

PURPOSE: In this study, we aimed to determine vascular changes in the testes in patients with varicocele using the two-dimensional color superb microvascular imaging vascular index (2DcSMIVI) and compared them with those of the normal contralateral testes of the same patients as well as the normal testes of control subjects without varicocele. METHODS: A total of 114 participants and 228 testes were included in the study. 63 patients with varicocele and 51 asymptomatic volunteers were included. In total, 70 testes with varicocele (group A), 56 normal contralateral testes (Group B), and 102 bilateral normal testes were classified (Group C). Participants' testicular volume and 2DcSMIVI values were obtained via superb microvascular imaging. Testes with varicocele were graded according to Sarteschi classification. RESULTS: Statistically significant differences in mean testicular volume were observed among the three groups. The volume and 2DcSMIVI values of the varicocele side testes were significantly lower than those of groups B and C. Significant differences were also observed between Sarteschi grade and 2DcSMIVI values in group A. CONCLUSION: We can determine impaired microcirculation of varicocele side testes quantitatively with the 2DcSMIVI technique, and obtained VI values can be used effectively in diagnosis and follow-up of the damage in testes. Our results show that 2DcSMIVI values can play a significant role in the evaluation of testicular blood flow as a predictive sign of testicular damage.


Subject(s)
Testis , Varicocele , Angiography , Healthy Volunteers , Humans , Male , Testis/diagnostic imaging , Ultrasonography, Doppler/methods , Varicocele/diagnostic imaging
4.
J Ultrasound ; 25(1): 27-33, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33453056

ABSTRACT

PURPOSE: The purpose of this study was to investigate the effectiveness of the vascularization index (VI) obtained using color superb microvascular imaging (cSMI) technique in assessment of the anterior urinary bladder wall in pediatric patients with acute cystitis (AC). METHODS: The anterior bladder wall of 157 patients (age range 13-84 months, mean 43.62 ± 17.79 months) whose clinical and laboratory findings were proven of AC and 150 healthy asymptomatic participants (age range 13-84 months, mean 43.88 ± 18.11 months) with normal laboratory values were examined using cSMI. VI measurements were performed by manually drawing the contours of the anterior bladder wall using the free region of interest with 2-dimensional cSMI VI (2DcSMIVI) mode. The quantitative 2DcSMIVI values of the symptomatic group and the asymptomatic group were compared. The correlation between the 2DcSMIVI values and the anterior bladder wall thickness (BWT) were analyzed. RESULTS: The mean 2DcSMIVI values of the BWT were significantly higher in symptomatic group when compared to the asymptomatic group (p<0.001). AC can be diagnosed with a 93% sensitivity, 92% specificity when 3.25% 2DcSMIVI designated as the cutoff value. There was a significant positive correlation between 2DcSMIVI values and BWT (p<0.001). CONCLUSION: Two-dimensional cSMI VI can be used effectively in children as an imaging method in the diagnosis of AC.


Subject(s)
Cystitis , Urinary Bladder , Angiography , Child , Child, Preschool , Cystitis/diagnostic imaging , Humans , Infant , Reference Values , Ultrasonography/methods , Ultrasonography, Doppler/methods , Urinary Bladder/diagnostic imaging
5.
J Ultrason ; 21(84): 41-47, 2021.
Article in English | MEDLINE | ID: mdl-33796339

ABSTRACT

AIM OF THE STUDY: To determine the parenchymal vascularity of the thyroid gland with color superb microvascular imaging in patients with Graves' disease, and compare the vascularization index values with healthy subjects. MATERIALS AND METHODS: The thyroid glands of 37 patients whose laboratory and clinical findings were consistent with Graves' disease, and 40 asymptomatic subjects with normal laboratory values, were examined using color superb microvascular imaging. Measurements of the vascularization index were performed with a free region of interest which was drawn along the outer margin of the gland on the color superb microvascular imaging mode. The vascularization index values obtained in the Graves' disease and control groups were compared. A correlation analysis was performed between the vascularization index values and laboratory and grayscale US parameters. RESULTS: The median vascularization index value of the thyroid parenchyma in patients with Graves' disease was significantly higher than in the asymptomatic group [median (min-max); 12 (2.3-32.1) vs 5.04 (1.1-10.8), p <0.001]. When the cutoff value of the vascularization index is determined as 6.3, Graves' disease can be diagnosed with 83.8% sensitivity and 70% specificity. CONCLUSIONS: The vascularization index obtained with color superb microvascular imaging can be a quantitative indicator of parenchymal vascularity in the diagnosis of Graves' disease, and serve as a supportive tool.

6.
Med Ultrason ; 23(2): 181-187, 2021 May 20.
Article in English | MEDLINE | ID: mdl-33626117

ABSTRACT

AIM: We compared the two-dimensional shear-wave elastography (2D-SWE) values between the testes with same side operated inguinal hernia (IH) and the contralateral testes, as well as the testes of healthy volunteers without IH. MATERIAL AND METHODS: A total of 189 participants (117 unilateral [117 testes] and 8 bilateral operated IH patients [16 testes] and 64 healthy volunteers [128 testes]), providing a total of 378 testicles, were investigated prospectively. All patients underwent B-mode ultrasonography (US) and 2D-SWE examinations. Operation type, the period between diagnosis and operation, the period since the operation, testes volumes, and 2D-SWE values were compared. RESULTS: The B-mode US finding of the testes were normal in all participants. The mean testes' volume of same side operated IH was significantly lower comparing to contralat-eral testes and the healthy group (p<0.001). The 2D-SWE values of the testes with same side operated IH were significantly higher comparing to the contralateral testes and the healthy group (p<0.001). There was a statistically significant correlation between 2D-SWE values and IH severity, as well as the duration of the hernia (p=0.001). There was no significant correlation between the IH severity and testes volume (p=0.285). No significant difference was found between the direct and indirect IH in terms of testicular volume and SWE values and between the duration of the hernia, the time after sugery, testicular volume and SWE values according to operation techniques(p>0.005). CONCLUSIONS: The 2D-SWE can be used as an effective imag-ing method to evaluate testicular stiffness with objective numerical values, to estimate the severity of histologic damage in patients with operated IH.


Subject(s)
Elasticity Imaging Techniques , Hernia, Inguinal , Hernia, Inguinal/diagnostic imaging , Hernia, Inguinal/surgery , Humans , Male , Testis/diagnostic imaging , Ultrasonography
7.
Turk J Med Sci ; 51(3): 972-980, 2021 06 28.
Article in English | MEDLINE | ID: mdl-33421971

ABSTRACT

Background/aim: To investigate the changes in the spleen size, parenchymal heterogeneity, and computed tomography (CT) texture analysis features of patients diagnosed with Coronavirus disease 2019 (COVID-19) Materials and methods: The size and parenchymal structure of the spleen in 91 patients who underwent thoracic CT examination due to COVID-19 were evaluated. For the evaluation of parenchymal heterogeneity, CT texture analysis was performed using dedicated software (Olea Medical, France). The texture analysis of each case consisted of 15 first-order intensity-based features, 17 gray level co- occurrence matrix-based features, and 9 gray level run length matrix-based features. Results: A total of 91 patients (45 males, 46 females) with a mean age of 54.31 ± 16.33 years (range: 18­81) were included in the study. A statistically significant decrease in spleen size was seen in the follow-up CT examinations (p < 0.001) whereas no statistically significant difference was found between the Hounsfield unit (HU) values. The radiomics consisted of first-order intensity-based features such as 90th percentile, maximum, interquartile range, range, mean absolute deviation, standard deviation, and variance, all of which showed statistically significant differences (p-values: < 0.001, < 0.001, 0.001, 0.003, 0.001, 0.001, and 0.004, respectively). "Correlation" as a gray level co-occurrence matrix-based feature and "gray level nonuniformity" as a gray level run length matrix-based feature showed statistically differences (p-values: 0.033 and < 0.001, respectively). Conclusions: Although COVID-19 manifests with lung involvement in the early stage, it can also cause systemic involvement, and the spleen may be one of its target organs. A decrease in the spleen size and parenchymal microstructure changes can be observed in the short follow-up time. It is hoped that the changes in the parenchymal microstructure will be demonstrated by a noninvasive method: texture analysis.


Subject(s)
COVID-19/diagnosis , SARS-CoV-2 , Spleen/diagnostic imaging , Splenic Diseases/epidemiology , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , COVID-19/epidemiology , Comorbidity , Female , Follow-Up Studies , Humans , Male , Middle Aged , Pandemics , Retrospective Studies , Splenic Diseases/diagnosis , Turkey/epidemiology , Young Adult
8.
J Pediatr Endocrinol Metab ; 33(9): 1139-1145, 2020 Sep 25.
Article in English | MEDLINE | ID: mdl-32809960

ABSTRACT

Objectives To define thyroid gland vascularity index (VI) values in healthy children with the superb microvascular imaging (SMI) method and to assess whether or not there is a correlation with potential factors that may affect these values. Methods This prospective study included a total of 138 children, their ages varying from 3-17 years. Cases were divided into three subgroups according to age: 3-6, 7-12 and 13-17 years. Gender, age, height, weight, body mass index (BMI), thyroid-stimulating hormone (TSH) and free thyroxine (fT4) values were recorded. Volume and SMI measurements were performed with a 14 L5 mHz linear transducer. VI measurements were performed in the transverse and longitudinal planes and correlation with basic descriptive data was researched. Results Mean age was 11.14 ± 3.34 years and BMI was 19.95 ± 4.92. VI values were 4.59 ± 2.34 in the right lobe and 4.23 ± 2.73 for the left lobe, with no significant difference identified. There were no significant differences in mean VI for all parenchyma regarding gender and age groups. While there was no correlation identified with mean VI for all parenchyma with TSH and fT4, there was, however, a negative correlation with BMI. Conclusions Reference VI values for normal thyroid glands in healthy children and adolescents were defined with the SMI method. There was no correlation between the VI values and age, gender, volume, TSH and fT4 values, while there was a negative significant correlation with BMI.


Subject(s)
Body Mass Index , Image Processing, Computer-Assisted/methods , Thyroid Gland/blood supply , Thyroid Gland/diagnostic imaging , Thyroid Hormones/blood , Ultrasonography, Doppler/methods , Adolescent , Child , Child, Preschool , Female , Follow-Up Studies , Humans , Male , Prognosis , Prospective Studies , Thyroid Gland/metabolism
9.
J Ultrasound ; 23(4): 543-551, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32185701

ABSTRACT

PURPOSE: We aimed to investigate the use and effectiveness of Shear-Wave Elastography (SWE) in Hashimoto's Thyroiditis (HT) diagnosis and compare the SWE values in HT patients with asymptomatic volunteers. METHODS: The thyroid gland parenchyma of 74 patients whose clinical and laboratory findings and ultrasonography (US) features were indicative of HT and 75 healthy, asymptomatic participants with normal laboratory values were examined using SWE. Their thyroid parenchymal echoes and thyroid gland volume were measured using B-mode US examination. Elastographic measurements were made by plotting the boundaries of thyroid gland by hand, using Free Region of Interest (ROI). The quantitative SWE values [meters/second (m/s) and kilopascal (kPa)] were compared betweent the patients and the controls. The correlation analyses between the SWE measurements and the autoantibodies [Anti-thyroid peroxidase antibody (TPOAbs) and anti-thyroglobulin antibodies (TgAbs)], thyroid-stimulating hormone (TSH), freetriiodothyronine (fT3), free-thyroxine (fT4), and thyroglobulin levels were performed. RESULTS: The mean thyroid SWE measurement values of HT group were significantly higher than the asymptomatic group (p < 0.001). This study proposes 29.45 kPa or 2.77 m/s as a sensitive-spesific cut-off value for HT. We revealed significant positive association between SWE values and TgAb levels, gland volume, TgAb, TPOAb levels, and a significant negative association between SWE and echogenicity (p < 0.001). CONCLUSION: In the assessment of HT, SWE is a highly sensitive imaging method to estimate the degree of fibrosis and to provide objective numerical values.


Subject(s)
Elasticity Imaging Techniques , Hashimoto Disease/diagnostic imaging , Thyroid Gland/diagnostic imaging , Adolescent , Adult , Autoantibodies/blood , Case-Control Studies , Child , Female , Hashimoto Disease/immunology , Hashimoto Disease/pathology , Humans , Male , Middle Aged , ROC Curve , Thyroid Gland/pathology , Young Adult
10.
Ultrasound Q ; 35(3): 281-289, 2019 Sep.
Article in English | MEDLINE | ID: mdl-30855420

ABSTRACT

The study aimed to investigate the effectiveness of the vascularization index (VI) obtained using superb microvascular imaging (SMI) technique in the diagnosis of Hashimoto thyroiditis (HT). The thyroid glands of 80 patients with HT and 107 healthy, asymptomatic participants were examined using SMI. The thyroid parenchyma echogenicity was evaluated, and the thyroid gland volume was measured. Vascularization index measurements were performed by manually drawing the contours of the thyroid parenchyma using the free region of interest with color 2-dimensional SMI VI mode. The quantitative VI values of the patients and the asymptomatic group were compared. Correlations between VI values and thyroid autoantibodies and thyroid hormone levels were analyzed. The mean VI value of the thyroid gland was 4.74% ± 1.96% in the asymptomatic group and 12.45% ± 5.87% in HT patients with a statistically significant difference (P < 0.001). Hashimoto thyroiditis can be diagnosed with 86.3% sensitivity and 82.2% specificity when 6.00% VI value was designated as the cutoff value. There was a positive significant correlation between the VI value and the thyroid-stimulating hormone, antithyroglobulin antibodies, anti-thyroid peroxidase antibody levels (P < 0.05); however, no significant correlation was found between the VI values and thyroglobulin and free thyroxine levels (P > 0.05). There was a significant negative correlation between the VI values and the parenchyma echogenicity and positive significant correlation between the thyroid gland volume and the antithyroglobulin antibody and anti-thyroid peroxidase antibody levels (P < 0.05). The VI obtained using the SMI technique can be effectively used as an imaging method for the diagnosis of HT because of its high sensitivity and specificity in representing objective, quantitative numerical values.


Subject(s)
Hashimoto Disease/diagnostic imaging , Microvessels/diagnostic imaging , Thyroid Gland/blood supply , Thyroid Gland/diagnostic imaging , Ultrasonography/methods , Adolescent , Child , Child, Preschool , Evaluation Studies as Topic , Female , Humans , Male , Sensitivity and Specificity
11.
Scand J Clin Lab Invest ; 71(3): 227-31, 2011 May.
Article in English | MEDLINE | ID: mdl-21294669

ABSTRACT

BACKGROUND: Intact parathyroid hormone (iPTH) assays react with the non-(1-84) molecular form of PTH. This form behaves as a carboxy-terminal fragment and accumulates during renal failure. We wanted to examine the variation of iPTH levels between the more commonly used different immunoassay methods in hemodialysis patients. METHODS: Our study was designed to compare three commercial second-generation immunoassays based on electrochemiluminescent immunoassay (ECLIA), enzyme immunoassay (EIA) and immunoradiometric assay (IRMA) for intact PTH. The serum samples from 88 patients were collected and the iPTH concentrations measured. RESULTS: The median iPTH (IRMA) concentration (99 pg/mL) was lower than both median iPTH (ECLIA) concentration (290.5 pg/ml; p < 0.001) and iPTH (EIA) concentration (369 pg/mL; p < 0.001). The Bland-Altman graphs, which are plots of the percentage differences between the two methods against their mean, suggested that the IRMA methods are not in agreement with the other methods. CONCLUSION: It would be useful to reduce the variability among the methods with the use of a more standardized calibrator and of the same specific antibodies that only recognize the active PTH molecule.


Subject(s)
Parathyroid Hormone/blood , Renal Dialysis , Adult , Female , Humans , Immunoassay/methods , Male , Middle Aged , Renal Insufficiency/metabolism , Renal Insufficiency/therapy , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...