Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
J Cardiovasc Echogr ; 29(1): 7-13, 2019.
Article in English | MEDLINE | ID: mdl-31008031

ABSTRACT

AIM: This study aims to propose protocols that enable scoring of mitral valve (MV) in mitral stenosis using the three-dimensional (3D) scoring system. METHODS: A two-staged study was conducted. The first stage was designed to select the best 3D images of MV leaflets and chordae through analysis of 471 images. The second stage was designed to organize the best 3D images into protocols for complete scoring of MV. It included 35 consecutive patients; 23 had sinus rhythm (SR) and 12 had atrial fibrillation (AF). Both single- and multi-beat 3D acquisition from apical and parasternal windows were focused on MV leaflets and chordae using all 3D modalities (live, zoom, and full volume). To propose the protocols, 1563 images were analyzed. RESULTS: In SR with good apical window, 2 protocols were recommended for complete scoring of leaflets and chordae (4 zoom 3D images [1 image for leaflets and 3 images for chordae] and 1 full-volume 3D image) using single- and multi-beat acquisition. In AF, the same 2 protocols using single-beat acquisition were recommended. From parasternal window, complete scoring of leaflets was obtained by 3 recommended protocols (single- or multi-beat zoom 3D images from parasternal short axis [PSAX], multibeat live 3D images from PSAX, and single- or multi-beat full-volume 3D images from parasternal long axis) in SR and 1 protocol in AF (single-beat zoom 3D images from PSAX). Scoring of chordae was incomplete in all patients by all 3D modalities. CONCLUSIONS: The proposed 3D-transthoracic echocardiography protocols suit all patients regardless of echo window and heart rhythm and enabled complete MV scoring.

3.
J Am Soc Echocardiogr ; 23(1): 13-22, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19926444

ABSTRACT

BACKGROUND: The aim of this study was to validate a new real-time three-dimensional echocardiography (RT3DE) score for evaluating patients with mitral stenosis (MS). METHODS: A two-staged study was conducted. In the first stage, the feasibility of a new RT3DE score was assessed in 17 patients with MS. The second stage was planned to validate the RT3DE score in 74 consecutive patients undergoing percutaneous mitral valvuloplasty. The new RT3DE score was constructed by dividing each mitral valve (MV) leaflet into 3 scallops and was composed of 31 points (indicating increasing abnormality), including 6 points for thickness, 6 for mobility, 10 for calcification, and 9 for subvalvular apparatus involvement. The total RT3DE score was calculated and defined as mild (<8), moderate (8-13), or severe (>or=14). MV morphology was assessed using Wilkins's score and compared with the new RT3DE score. RESULTS: In the first stage, the RT3DE score was feasible and easily applied to all patients, with good interobserver and intraobserver agreement. In the second stage, RT3DE improved MV morphologic assessment, particularly for the detection of calcification and commissural splitting. Both scores were correlated for assessment of thickness and calcification (r = 0.63, P < .0001, and r = 0.44, P < .0001, respectively). Predictors of optimal percutaneous mitral valvuloplasty success by Wilkins's score were leaflet calcification and subvalvular apparatus involvement, and those by RT3DE score were leaflet mobility and subvalvular apparatus involvement. The incidence and severity of mitral regurgitation were associated with high-calcification RT3DE score. CONCLUSION: The new RT3DE score is feasible and highly reproducible for the assessment of MV morphology in patients with MS. It can provide incremental prognostic information in addition to Wilkins's score.


Subject(s)
Algorithms , Echocardiography, Three-Dimensional/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Mitral Valve Stenosis/diagnostic imaging , Adult , Computer Systems , Feasibility Studies , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
4.
Echocardiography ; 25(5): 534-6, 2008 May.
Article in English | MEDLINE | ID: mdl-18279405

ABSTRACT

The right atrioventricular valve is formed by three leaflets as described by the classic anatomic studies. Two-dimensional transthoracic echocardiography (2DE) shows the tricuspid valve (TV) in its long axis. However, short-axis views of the TV leaflets are not generally obtained and therefore distinction between leaflets by 2DE is difficult. Real time three-dimensional echocardiography (RT3DE) overcomes this limitation of 2DE and facilitates obtaining short axis view (enface view) of the TV. In the current case study, en face view of the TV obtained by RT3DE was found to be formed of only two leaflets with two commissures. The surgical findings were consistent with that of RT3DE.


Subject(s)
Echocardiography, Three-Dimensional , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve/abnormalities , Adult , Electrocardiography , Humans , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...