Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Hosp Infect ; 149: 26-35, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38705476

ABSTRACT

BACKGROUND: The environmental surveillance of air grilles in clinical areas has not been systematically analysed. METHODS: Samples were collected from frequently touched items (N = 529), air supply (N = 295) and exhaust (N = 184) grilles in six medical and 11 surgical wards for the cultures of multi-drug-resistant organisms (MDROs): meticillin-resistant Staphylococcus aureus (MRSA), carbapenem-resistant Acinetobacter baumannii (CRAB) and carbapenemase-producing Enterobacterales (CPE), and isolates were selected for whole-genome sequencing (WGS). The contamination rates were correlated with the colonization pressures of the respective MDROs. RESULTS: From 3rd October to 21st November 2023, 9.8% (99/1008) of the samples tested positive, with MRSA (24.2%, 24/99), CRAB (59.6%, 59/99) and CPE (2.0%, 2/99), being the only detected MDROs. The contamination rate in air exhaust grilles (26.6%, 49/184) was significantly higher than in air supply grilles (5.8%, 17/295; P<0.001). The contamination rate of air exhaust grilles with any MDRO in acute medical wards (73.7%, 14/19) was significantly higher than in surgical wards (12.5%, 4/32; P<0.001). However, there was no difference in the contamination rate of air exhaust grilles between those located inside and outside the cohort cubicles for MDROs (27.1%, 13/48 vs 28.8%, 30/104; P=0.823). Nevertheless, the weekly CRAB colonization pressure showed a significant correlation with the overall environmental contamination rate (r = 0.878; 95% confidence interval (CI): 0.136-0.986; P=0.004), as well as with the contamination rate in air supply grilles (r = 0.960; 95% CI: 0.375-0.999; P<0.001) and air exhaust grilles (r = 0.850; 95% CI: 0.401-0.980; P=0.008). WGS demonstrated clonal relatedness of isolates collected from patients and air exhaust grilles. CONCLUSIONS: Air grilles may serve as MDRO reservoirs. Cohort nursing in open cubicles may not completely prevent MDRO transmission through air dispersal, prompting the consideration of future hospital design.


Subject(s)
Acinetobacter baumannii , Air Microbiology , Drug Resistance, Multiple, Bacterial , Methicillin-Resistant Staphylococcus aureus , Humans , Acinetobacter baumannii/genetics , Acinetobacter baumannii/drug effects , Acinetobacter baumannii/isolation & purification , Methicillin-Resistant Staphylococcus aureus/genetics , Methicillin-Resistant Staphylococcus aureus/isolation & purification , Methicillin-Resistant Staphylococcus aureus/drug effects , Drug Resistance, Multiple, Bacterial/genetics , Bacterial Proteins/genetics , beta-Lactamases/genetics , Whole Genome Sequencing , Carbapenem-Resistant Enterobacteriaceae/genetics , Carbapenem-Resistant Enterobacteriaceae/isolation & purification , Carbapenems/pharmacology
2.
J Hosp Infect ; 123: 52-60, 2022 May.
Article in English | MEDLINE | ID: mdl-35196559

ABSTRACT

BACKGROUND: Meticillin-resistant Staphylococcus aureus (MRSA) infections are rampant in hospitals and residential care homes for the elderly (RCHEs). AIM: To analyse the prevalence of MRSA colonization among residents and staff, and degree of environmental contamination and air dispersal of MRSA in RCHEs. METHODS: Epidemiological and genetic analysis by whole-genome sequencing (WGS) in 12 RCHEs in Hong Kong. FINDINGS: During the COVID-19 pandemic (from September to October 2021), 48.7% (380/781) of RCHE residents were found to harbour MRSA at any body site, and 8.5% (8/213) of staff were nasal MRSA carriers. Among 239 environmental samples, MRSA was found in 39.0% (16/41) of randomly selected resident rooms and 31.3% (62/198) of common areas. The common areas accessible by residents had significantly higher MRSA contamination rates than those that were not accessible by residents (37.2%, 46/121 vs. 22.1%, 17/177, P=0.028). Of 124 air samples, nine (7.3%) were MRSA-positive from four RCHEs. Air dispersal of MRSA was significantly associated with operating indoor fans in RCHEs (100%, 4/4 vs. 0%, 0/8, P=0.002). WGS of MRSA isolates collected from residents, staff and environmental and air samples showed that ST 1047 (CC1) lineage 1 constituted 43.1% (66/153) of all MRSA isolates. A distinctive predominant genetic lineage of MRSA in each RCHE was observed, suggestive of intra-RCHE transmission rather than clonal acquisition from the catchment hospital. CONCLUSION: MRSA control in RCHEs is no less important than in hospitals. Air dispersal of MRSA may be an important mechanism of dissemination in RCHEs with operating indoor fans.


Subject(s)
COVID-19 , Methicillin-Resistant Staphylococcus aureus , Staphylococcal Infections , Aged , COVID-19/epidemiology , Carrier State/epidemiology , Humans , Methicillin , Methicillin-Resistant Staphylococcus aureus/genetics , Pandemics , Staphylococcal Infections/epidemiology
3.
J Hosp Infect ; 116: 78-86, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34403765

ABSTRACT

AIM: To describe the nosocomial transmission of Air, multidrug-resistant, Acinetobacter baumannii, nosocomial, COVID-19 Acinetobacter baumannii (MRAB) in an open-cubicle neurology ward with low ceiling height, where MRAB isolates collected from air, commonly shared items, non-reachable high-level surfaces and patients were analysed epidemiologically and genetically by whole-genome sequencing. This is the first study to understand the genetic relatedness of air, environmental and clinical isolates of MRAB in the outbreak setting. FINDINGS: Of 11 highly care-dependent patients with 363 MRAB colonization days during COVID-19 pandemic, 10 (90.9%) and nine (81.8%) had cutaneous and gastrointestinal colonization, respectively. Of 160 environmental and air samples, 31 (19.4%) were MRAB-positive. The proportion of MRAB-contaminated commonly shared items was significantly lower in cohort than in non-cohort patient care (0/10, 0% vs 12/18, 66.7%; P<0.001). Air dispersal of MRAB was consistently detected during but not before diaper change in the cohort cubicle by 25-min air sampling (4/4,100% vs 0/4, 0%; P=0.029). The settle plate method revealed MRAB in two samples during diaper change. The proportion of MRAB-contaminated exhaust air grills was significantly higher when the cohort cubicle was occupied by six MRAB patients than when fewer than six patients were cared for in the cubicle (5/9, 55.6% vs 0/18, 0%; P=0.002). The proportion of MRAB-contaminated non-reachable high-level surfaces was also significantly higher when there were three or more MRAB patients in the cohort cubicle (8/31, 25.8% vs 0/24, 0%; P=0.016). Whole-genome sequencing revealed clonality of air, environment, and patients' isolates, suggestive of air dispersal of MRAB. CONCLUSIONS: Our findings support the view that patient cohorting in enclosed cubicles with partitions and a closed door is preferred if single rooms are not available.


Subject(s)
Acinetobacter Infections , Acinetobacter baumannii , COVID-19 , Cross Infection , Acinetobacter Infections/drug therapy , Acinetobacter Infections/epidemiology , Acinetobacter baumannii/genetics , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Cross Infection/drug therapy , Cross Infection/epidemiology , Drug Resistance, Multiple, Bacterial , Humans , Microbial Sensitivity Tests , Pandemics , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...