Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Science ; 383(6690): 1499-1504, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38547284

ABSTRACT

Methane emissions from solid waste may represent a substantial fraction of the global anthropogenic budget, but few comprehensive studies exist to assess inventory assumptions. We quantified emissions at hundreds of large landfills across 18 states in the United States between 2016 and 2022 using airborne imaging spectrometers. Spanning 20% of open United States landfills, this represents the most systematic measurement-based study of methane point sources of the waste sector. We detected significant point source emissions at a majority (52%) of these sites, many with emissions persisting over multiple revisits (weeks to years). We compared these against independent contemporaneous in situ airborne observations at 15 landfills and established good agreement. Our findings indicate a need for long-term, synoptic-scale monitoring of landfill emissions in the context of climate change mitigation policy.

2.
Proc Natl Acad Sci U S A ; 113(35): 9734-9, 2016 08 30.
Article in English | MEDLINE | ID: mdl-27528660

ABSTRACT

Methane (CH4) impacts climate as the second strongest anthropogenic greenhouse gas and air quality by influencing tropospheric ozone levels. Space-based observations have identified the Four Corners region in the Southwest United States as an area of large CH4 enhancements. We conducted an airborne campaign in Four Corners during April 2015 with the next-generation Airborne Visible/Infrared Imaging Spectrometer (near-infrared) and Hyperspectral Thermal Emission Spectrometer (thermal infrared) imaging spectrometers to better understand the source of methane by measuring methane plumes at 1- to 3-m spatial resolution. Our analysis detected more than 250 individual methane plumes from fossil fuel harvesting, processing, and distributing infrastructures, spanning an emission range from the detection limit [Formula: see text] 2 kg/h to 5 kg/h through [Formula: see text] 5,000 kg/h. Observed sources include gas processing facilities, storage tanks, pipeline leaks, and well pads, as well as a coal mine venting shaft. Overall, plume enhancements and inferred fluxes follow a lognormal distribution, with the top 10% emitters contributing 49 to 66% to the inferred total point source flux of 0.23 Tg/y to 0.39 Tg/y. With the observed confirmation of a lognormal emission distribution, this airborne observing strategy and its ability to locate previously unknown point sources in real time provides an efficient and effective method to identify and mitigate major emissions contributors over a wide geographic area. With improved instrumentation, this capability scales to spaceborne applications [Thompson DR, et al. (2016) Geophys Res Lett 43(12):6571-6578]. Further illustration of this potential is demonstrated with two detected, confirmed, and repaired pipeline leaks during the campaign.

3.
Astrobiology ; 14(7): 577-88, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24963874

ABSTRACT

The successes of the Mars exploration program have led to our unprecedented knowledge of the geological, mineralogical, and elemental composition of the martian surface. To date, however, only one mission, the Phoenix lander, has specifically set out to determine the soluble chemistry of the martian surface. The surprising results, including the detection of perchlorate, demonstrated both the importance of performing soluble ion measurements and the need for improved instrumentation to unambiguously identify all the species present. Ion chromatography (IC) is the state-of-the-art technique for soluble ion analysis on Earth and would therefore be the ideal instrument to send to Mars. A flight IC system must necessarily be small, lightweight, low-power, and have low eluent consumption. We demonstrate here a breadboard system that addresses these issues by using capillary IC at low flow rates with an optimized eluent generator and suppressor. A mix of 12 ions known or plausible for the martian soil, including 4 (oxy)chlorine species, has been separated at flow rates ranging from 1 to 10 µL/min, requiring as little as 200 psi at 1.0 µL/min. This allowed the use of pneumatic displacement pumping from a pressurized aluminum eluent reservoir and the elimination of the high-pressure pump entirely (the single heaviest and most energy-intensive component). All ions could be separated and detected effectively from 0.5 to 100 µM, even when millimolar concentrations of perchlorate were present in the same mixtures.


Subject(s)
Chromatography, Ion Exchange/methods , Extraterrestrial Environment/chemistry , Mars , Soil/chemistry , Chlorates/analysis , Chlorides/analysis , Chromatography, Ion Exchange/instrumentation , Perchlorates/analysis , Sulfates/analysis
4.
Science ; 341(6143): 260-3, 2013 Jul 19.
Article in English | MEDLINE | ID: mdl-23869013

ABSTRACT

Stable isotope ratios of H, C, and O are powerful indicators of a wide variety of planetary geophysical processes, and for Mars they reveal the record of loss of its atmosphere and subsequent interactions with its surface such as carbonate formation. We report in situ measurements of the isotopic ratios of D/H and (18)O/(16)O in water and (13)C/(12)C, (18)O/(16)O, (17)O/(16)O, and (13)C(18)O/(12)C(16)O in carbon dioxide, made in the martian atmosphere at Gale Crater from the Curiosity rover using the Sample Analysis at Mars (SAM)'s tunable laser spectrometer (TLS). Comparison between our measurements in the modern atmosphere and those of martian meteorites such as ALH 84001 implies that the martian reservoirs of CO2 and H2O were largely established ~4 billion years ago, but that atmospheric loss or surface interaction may be still ongoing.

5.
IEEE Trans Vis Comput Graph ; 19(7): 1228-41, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23661013

ABSTRACT

Natural image statistics is an important area of research in cognitive sciences and computer vision. Visualization of statistical results can help identify clusters and anomalies as well as analyze deviation, distribution, and correlation. Furthermore, they can provide visual abstractions and symbolism for categorized data. In this paper, we begin our study of visualization of image statistics by considering visual representations of power spectra, which are commonly used to visualize different categories of images. We show that they convey a limited amount of statistical information about image categories and their support for analytical tasks is ineffective. We then introduce several new visual representations, which convey different or more information about image statistics. We apply ANOVA to the image statistics to help select statistically more meaningful measurements in our design process. A task-based user evaluation was carried out to compare the new visual representations with the conventional power spectra plots. Based on the results of the evaluation, we made further improvement of visualizations by introducing composite visual representations of image statistics.


Subject(s)
Algorithms , Visual Perception , Adult , Analysis of Variance , Female , Humans , Male , Photic Stimulation , User-Computer Interface , Young Adult
6.
Proc Natl Acad Sci U S A ; 108(14): 5526-31, 2011 Apr 05.
Article in English | MEDLINE | ID: mdl-21422282

ABSTRACT

Archived samples from a previously unreported 1958 Stanley Miller electric discharge experiment containing hydrogen sulfide (H(2)S) were recently discovered and analyzed using high-performance liquid chromatography and time-of-flight mass spectrometry. We report here the detection and quantification of primary amine-containing compounds in the original sample residues, which were produced via spark discharge using a gaseous mixture of H(2)S, CH(4), NH(3), and CO(2). A total of 23 amino acids and 4 amines, including 7 organosulfur compounds, were detected in these samples. The major amino acids with chiral centers are racemic within the accuracy of the measurements, indicating that they are not contaminants introduced during sample storage. This experiment marks the first synthesis of sulfur amino acids from spark discharge experiments designed to imitate primordial environments. The relative yield of some amino acids, in particular the isomers of aminobutyric acid, are the highest ever found in a spark discharge experiment. The simulated primordial conditions used by Miller may serve as a model for early volcanic plume chemistry and provide insight to the possible roles such plumes may have played in abiotic organic synthesis. Additionally, the overall abundances of the synthesized amino acids in the presence of H(2)S are very similar to the abundances found in some carbonaceous meteorites, suggesting that H(2)S may have played an important role in prebiotic reactions in early solar system environments.


Subject(s)
Amines/chemical synthesis , Amino Acids/chemical synthesis , Evolution, Chemical , Hydrogen Sulfide/chemistry , Origin of Life , Ammonia , Carbon Dioxide , Chromatography, High Pressure Liquid , Mass Spectrometry , Methane
7.
Nucleic Acids Res ; 37(10): 3215-29, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19321502

ABSTRACT

Despite being plagued by heavily degraded DNA in palaeontological remains, most studies addressing the state of DNA degradation have been limited to types of damage which do not pose a hindrance to Taq polymerase during PCR. Application of serial qPCR to the two fractions obtained during extraction (demineralization and protein digest) from six permafrost mammoth bones and one partially degraded modern elephant bone has enabled further insight into the changes which endogenous DNA is subjected to during diagenesis. We show here that both fractions exhibit individual qualities in terms of the prevailing type of DNA (i.e. mitochondrial versus nuclear DNA) as well as the extent of damage, and in addition observed a highly variable ratio of mitochondrial to nuclear DNA among the six mammoth samples. While there is evidence suggesting that mitochondrial DNA is better preserved than nuclear DNA in ancient permafrost samples, we find the initial DNA concentration in the bone tissue to be as relevant for the total accessible mitochondrial DNA as the extent of DNA degradation post-mortem. We also evaluate the general applicability of indirect measures of preservation such as amino-acid racemization, bone crystallinity index and thermal age to these exceptionally well-preserved samples.


Subject(s)
Bone and Bones/chemistry , DNA Damage , DNA/analysis , Elephants/genetics , Paleontology , Animals , Cell Nucleus/genetics , Cytosine/chemistry , DNA/chemistry , DNA/isolation & purification , DNA, Mitochondrial/analysis , DNA, Mitochondrial/isolation & purification , Deamination , Freezing , Polymerase Chain Reaction , Preservation, Biological , Principal Component Analysis , Temperature
8.
Astrobiology ; 8(3): 583-95, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18680409

ABSTRACT

The Urey organic and oxidant detector consists of a suite of instruments designed to search for several classes of organic molecules in the martian regolith and ascertain whether these compounds were produced by biotic or abiotic processes using chirality measurements. These experiments will also determine the chemical stability of organic molecules within the host regolith based on the presence and chemical reactivity of surface and atmospheric oxidants. Urey has been selected for the Pasteur payload on the European Space Agency's (ESA's) upcoming 2013 ExoMars rover mission. The diverse and effective capabilities of Urey make it an integral part of the payload and will help to achieve a large portion of the mission's primary scientific objective: "to search for signs of past and present life on Mars." This instrument is named in honor of Harold Urey for his seminal contributions to the fields of cosmochemistry and the origin of life.


Subject(s)
Extraterrestrial Environment/chemistry , Mars , Organic Chemicals/analysis , Oxidants/analysis , Space Flight/instrumentation , Amino Acids/chemistry , Electrophoresis, Capillary , Fluorescamine/chemistry , Microchip Analytical Procedures , Stereoisomerism
9.
Proc Natl Acad Sci U S A ; 102(4): 1041-6, 2005 Jan 25.
Article in English | MEDLINE | ID: mdl-15657130

ABSTRACT

The Mars Organic Analyzer (MOA), a microfabricated capillary electrophoresis (CE) instrument for sensitive amino acid biomarker analysis, has been developed and evaluated. The microdevice consists of a four-wafer sandwich combining glass CE separation channels, microfabricated pneumatic membrane valves and pumps, and a nanoliter fluidic network. The portable MOA instrument integrates high voltage CE power supplies, pneumatic controls, and fluorescence detection optics necessary for field operation. The amino acid concentration sensitivities range from micromolar to 0.1 nM, corresponding to part-per-trillion sensitivity. The MOA was first used in the lab to analyze soil extracts from the Atacama Desert, Chile, detecting amino acids ranging from 10-600 parts per billion. Field tests of the MOA in the Panoche Valley, CA, successfully detected amino acids at 70 parts per trillion to 100 parts per billion in jarosite, a sulfate-rich mineral associated with liquid water that was recently detected on Mars. These results demonstrate the feasibility of using the MOA to perform sensitive in situ amino acid biomarker analysis on soil samples representative of a Mars-like environment.


Subject(s)
Amino Acids/analysis , Electrophoresis, Capillary/instrumentation , Mars , Biomarkers , Chromatography, High Pressure Liquid
10.
Appl Environ Microbiol ; 70(10): 5923-8, 2004 Oct.
Article in English | MEDLINE | ID: mdl-15466534

ABSTRACT

We have developed a new method based on the sublimation of adenine from Escherichia coli to estimate bacterial cell counts in natural samples. To demonstrate this technique, several types of natural samples, including beach sand, seawater, deep-sea sediment, and two soil samples from the Atacama Desert, were heated to a temperature of 500 degrees C for several seconds under reduced pressure. The sublimate was collected on a cold finger, and the amount of adenine released from the samples was then determined by high-performance liquid chromatography with UV absorbance detection. Based on the total amount of adenine recovered from DNA and RNA in these samples, we estimated bacterial cell counts ranging from approximately 10(5) to 10(9) E. coli cell equivalents per gram. For most of these samples, the sublimation-based cell counts were in agreement with total bacterial counts obtained by traditional DAPI (4,6-diamidino-2-phenylindole) staining.


Subject(s)
Colony Count, Microbial/methods , Environmental Microbiology , Adenine/analysis , Chromatography, High Pressure Liquid , Colony Count, Microbial/instrumentation , DNA/analysis , Escherichia coli/chemistry , Fluorescent Dyes , Geologic Sediments/microbiology , Hot Temperature , Indoles , Seawater/microbiology , Soil Microbiology , Staining and Labeling
SELECTION OF CITATIONS
SEARCH DETAIL
...