Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Tomography ; 8(1): 120-130, 2022 01 05.
Article in English | MEDLINE | ID: mdl-35076626

ABSTRACT

OBJECTIVE: To evaluate computed tomography angiography (CTA) data focusing on radiation dose parameters in Thais with Marfan syndrome (MFS) and estimate the distribution of cumulative radiation exposure from CTA surveillance and the risk of cancers. METHODS: Between 1st January 2015 and 31st December 2020, we retrospectively evaluated the cumulative CTA radiation doses of MFS patients who underwent CTA at Khon Kaen University Hospital, a leading teaching hospital and advanced tertiary care institution in northeastern Thailand. We utilized the Radiation Risk Assessment Tool (RadRAT) established at the National Cancer Institute in Bethesda, Maryland, to evaluate the risk of cancer-related CTA radiation. RESULTS: The study recruited 29 adult MFS patients who had CTA of the aorta during a 5-year study period with 89 CTA studies. The mean cumulative CTDI vol is 21.5 ± 14.68 mGy, mean cumulative DLP is 682.2 ± 466.7 mGy.cm, the mean baseline future risk for all cancer is 26,134 ± 7601 per 100,000, and the excess lifetime risk for all cancer is 2080.3 ± 1330 per 100,000. The excess lifetime risk of radiation-induced cancer associated with the CTA surveillance study is significantly lower than the risk of aortic dissection or rupture and lower than the baseline future cancer risk. CONCLUSIONS: We attempted to quantify the radiation-induced cancer risk from CTA surveillance imaging performed for MFS patients in this study, with all patients receiving a low-risk cumulative radiation dose (less than 1 Gy) and all patients having a low excessive lifetime risk of cancer as a result of CTA. The risk-benefit decision must be made at the point of care, and it entails balancing the benefits of surveillance imaging in anticipating rupture and providing practical, safe treatment, therefore avoiding morbidity and mortality.


Subject(s)
Marfan Syndrome , Neoplasms , Adult , Aorta/diagnostic imaging , Computed Tomography Angiography/adverse effects , Computed Tomography Angiography/methods , Humans , Marfan Syndrome/diagnostic imaging , Neoplasms/diagnostic imaging , Neoplasms/epidemiology , Radiation Dosage , Retrospective Studies , Thailand/epidemiology
2.
Egypt Heart J ; 74(1): 6, 2022 Jan 25.
Article in English | MEDLINE | ID: mdl-35076784

ABSTRACT

BACKGROUND: The number of coronary computed tomography angiography (CCTA) exams is steadily growing. A novel computed tomography (CT) system has been developed to increase image quality while lowering patient radiation. The radiation dose attributed to CCTA has received considerable attention, whereas the dose associated with invasive catheter angiography (ICA) has received less. This study aims to investigate the radiation exposure of CCTA in patients and compare it to ICA. RESULTS: The mean effective dose of CCTA was 2.88 ± 0.85 mSv which was significantly lower than the mean effective dose of ICA (5.61 ± 0.55 mSv), p < 0.0001. The effective dose of CCTA correlated with the weight, height, and BMI, while the effective dose of ICA was associated with patient weight and BMI. The radiation exposure from CCTA has been considerably reduced over the last ten years by almost 2.5 folds. The mean radiation dose from the newer generation CT used in 2019 was significantly lower than that of the single-source CT in 2010 (2.88 ± 0.85 mSv vs. 7.15 ± 3.4 mSv, p < 0.001). CONCLUSIONS: CCTA allows evaluation of CAD with a significantly less effective radiation dose to patients than diagnostic ICA. There was a significant decrease in radiation dose from CCTA over time. Regular measurement of patient doses is an essential step to optimize exposure. It makes operators aware of their performance and allows comparisons with generally accepted practices.

SELECTION OF CITATIONS
SEARCH DETAIL
...