Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomed Mater Res A ; 101(3): 842-52, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22968914

ABSTRACT

We hypothesized that when compared with conventional two-dimensional (2D) cultures, substrates containing 3D micropillars would allow cells to grow at levels, activating their cytoskeleton to promote osteogenesis. Fibroblasts, osteoblast-like cells, and mesenchymal stem cells (MSCs) were studied. Planar substrates were compared with 200-nm-, 5-µm-, and 20-µm-high pillars of Ormocomp®, Si, diamond-like carbon, or TiO(2). Scanning electron microscopy and staining of actin cytoskeleton showed 7.5-h adhesion to pillar edges and 5-day stretching between adhesion contacts > 100-µm distances of fibroblast and MSC in 3D networks, whereas SaOS-2 cells adhered flatly and individually on horizontal and vertical surfaces. ERK and ROCK immunostaining at 14 and 21 days confirmed activation of the cytoskeleton. In contrast to expectations, success to induce osteogenesis was dominated by the cytocompatibility of the substrate over the 3D structure. This was shown using early alkaline phosphatase, intermediate osteopontin, and late mineralization markers, together with bone nodule formation, which were seen in planar substrates and low-profile TiO(2) pillars, but were poor in the 20-µm landscape. The lack of intercellular contacts seems to halt the osteogenesis-promoting effects of cytoskeletal organization and tension described earlier.


Subject(s)
Cell Differentiation , Fibroblasts/metabolism , Mesenchymal Stem Cells/metabolism , Osteoblasts/metabolism , Osteogenesis , Tissue Scaffolds/chemistry , Titanium/chemistry , Antigens, Differentiation/biosynthesis , Calcification, Physiologic , Cell Adhesion , Cell Line , Cytoskeleton/metabolism , Fibroblasts/cytology , Humans , Mesenchymal Stem Cells/cytology , Osteoblasts/cytology
2.
Anal Chim Acta ; 711: 69-76, 2012 Jan 20.
Article in English | MEDLINE | ID: mdl-22152798

ABSTRACT

We present rapid (<5 min) and efficient intact protein analysis by mass spectrometry (MS) using fully microfabricated and monolithically integrated capillary electrophoresis-electrospray ionization (CE-ESI) microchips. The microchips are fabricated fully of commercial inorganic-organic hybrid material, Ormocomp, by UV-embossing and adhesive Ormocomp-Ormocomp bonding (CE microchannels). A sheath-flow ESI interface is monolithically integrated with the UV-embossed separation channels by cutting a rectangular emitter tip in the end with a dicing saw. As a result, electrospray was produced from the corner of chip with good reproducibility between parallel tips (stability within 3.8-9.2% RSD). Thanks to its inherent biocompatibility and stable (negative) surface charge, Ormocomp microchips enable efficient intact protein analysis with up to ∼10(4) theoretical separation plates per meter without any chemical or physical surface modification before analysis. The same microchip setup is also feasible for rapid peptide sequencing and mass fingerprinting and shows excellent migration time repeatability from run to run for both peptides (5.6-5.9% RSD, n=4) and intact proteins (1.3-7.5% RSD, n=3). Thus, the Ormocomp microchips provide a versatile new tool for MS-based proteomics. Particularly, the feasibility of the Ormocomp chips for rapid analysis of intact proteins with such a simple setup is a valuable increment to the current technology.


Subject(s)
Electrophoresis, Capillary/instrumentation , Electrophoresis, Microchip/instrumentation , Proteins/chemistry , Spectrometry, Mass, Electrospray Ionization , Time Factors
4.
J Chromatogr A ; 1218(5): 739-45, 2011 Feb 04.
Article in English | MEDLINE | ID: mdl-21185563

ABSTRACT

Monolithically integrated, polymer (SU-8) microchips comprising an electrophoretic separation unit, a sheath flow interface, and an electrospray ionization (ESI) emitter were developed to improve the speed and throughput of metabolism research. Validation of the microchip method was performed using bufuralol 1-hydroxylation via CYP450 enzymes as the model reaction. The metabolite, 1-hydroxybufuralol, was easily separated from the substrate (R(s)=0.5) with very good detection sensitivity (LOD=9.3nM), linearity (range: 50-500nM, r(2)=0.9997), and repeatability (RSD(Area)=10.3%, RSD(Migrationtime)=2.5% at 80nM concentration without internal standard). The kinetic parameters of bufuralol 1-hydroxylation determined by the microchip capillary electrophoresis (CE)-ESI/mass spectrometry (MS) method, were comparable to the values presented in literature as well as to the values determined by in-house liquid chromatography (LC)-UV. In addition to enzyme kinetics, metabolic profiling was demonstrated using authentic urine samples from healthy volunteers after intake of either tramadol or paracetamol. As a result, six metabolites of tramadol and four metabolites of paracetamol, including both phase I oxidation products and phase II conjugation products, were detected and separated from each other within 30-35s. Before analysis, the urine samples were pre-treated with on-chip, on-line liquid-phase microextraction (LPME) and the results were compared to those obtained from urine samples pre-treated with conventional C18 solid-phase extraction (SPE, off-chip cartridges). On the basis of our results, the SU-8 CE-ESI/MS microchips incorporating on-chip sample pre-treatment, injection, separation, and ESI/MS detection were proven as efficient and versatile tools for drug metabolism research.


Subject(s)
Acetaminophen/metabolism , Electrophoresis, Microchip/methods , Epoxy Compounds/chemistry , Ethanolamines/metabolism , Models, Chemical , Polymers/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Tramadol/metabolism , Acetaminophen/urine , Acetates , Chemical Fractionation , Ethanolamines/analysis , Humans , Methanol , Reproducibility of Results , Sensitivity and Specificity , Tramadol/urine
5.
Electrophoresis ; 31(22): 3745-53, 2010 Nov.
Article in English | MEDLINE | ID: mdl-21077242

ABSTRACT

Monolithically integrated, polymer (SU-8) microchips comprising an electrophoretic separation unit, a sheath flow interface and an ESI emitter were developed to improve the speed and throughput of proteomics analyses. Validation of the microchip method was performed based on peptide mass fingerprinting and single peptide sequencing of selected protein standards. Rapid, yet reliable identification of four biologically important proteins (cytochrome C, ß-lactoglobulin, ovalbumin and BSA) confirmed the applicability of the SU-8 microchips to ambitious proteomic applications and allowed their use in the analysis of human muscle cell lysates. The characteristic tryptic peptides were easily separated with plate numbers approaching 10(6), and with peak widths at half height as low as 0.6 s. The on-chip sheath flow interface was also exploited to the introduction of an internal mass calibrant along with the sheath liquid which enabled accurate mass measurements by high-resolution Q-TOF MS. Additionally, peptide structural characterization and protein identification based on MS/MS fragmentation data of a single tryptic peptide was obtained using an ion trap instrument. Protein sequence coverages exceeding 50% were routinely obtained without any pretreatment of the proteolytic samples and a typical total analysis time from sampling to detection was well below ten minutes. In conclusion, monolithically integrated, dead-volume-free, SU-8 microchips proved to be a promising platform for fast and reliable analysis of complex proteomic samples. Good analytical performance of the microchips was shown by performing both peptide mass fingerprinting of complex cell lysates and protein identification based on single peptide sequencing.


Subject(s)
Cell Extracts/chemistry , Electrophoresis, Microchip/methods , Epoxy Compounds/chemistry , Peptide Fragments/analysis , Polymers/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Animals , Cattle , Chickens , Humans , Muscle Cells/chemistry , Peptide Fragments/metabolism , Peptide Mapping , Proteins/metabolism , Reproducibility of Results , Trypsin/metabolism
6.
Anal Chem ; 82(9): 3874-82, 2010 May 01.
Article in English | MEDLINE | ID: mdl-20394408

ABSTRACT

A new, commercial hybrid ceramic polymer, Ormocomp, was introduced to the fabrication of microfluidic separation chips using two independent techniques, UV lithography and UV embossing. Both fabrication methods provided Ormocomp chips with stable cathodic electroosmotic flow which enabled examination of the Ormocomp biocompatibility by means of microchip capillary electrophoresis (MCE) and (intrinsic) fluorescence detection. The hydrophobic/hydrophilic properties of Ormocomp were examined by screening its interactions with bovine serum albumin and selected amino acids of varying hydrophobicity. The results show that the ceramic, organic-inorganic polymer structure natively resists biofouling on microchannel walls even so that the Ormocomp microchips can be used in intact protein analysis without prior surface modification. With theoretical separation plates approaching 10(4) m(-1) for intact proteins and 10(6) m(-1) for amino acids and peptides, our results suggest that Ormocomp microchips hold record-breaking performance as microfluidic separation platforms. In addition, Ormocomp was shown to be suitable for optical fluorescence detection even at near-UV range (ex 355 nm) with detection limits at a nanomolar level ( approximately 200 nM) for selected inherently fluorescent pharmaceuticals.


Subject(s)
Ceramics/chemistry , Materials Testing , Microfluidics , Polymers/chemistry , Serum Albumin/chemistry , Animals , Biofouling , Cattle
7.
J Am Soc Mass Spectrom ; 20(9): 1723-30, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19559627

ABSTRACT

Matrix-free laser desorption/ionization was studied on two-layered sample plates consisting of a substrate and a thin film coating. The effect of the substrate material was studied by depositing thin films of amorphous silicon on top of silicon, silica, polymeric photoresist SU-8, and an inorganic-organic hybrid. Des-arg(9)-bradykinin signal intensity was used to evaluate the sample plates. Silica and hybrid substrates were found to give superior signals compared with silicon and SU-8 because of thermal insulation and compatibility with amorphous silicon deposition process. The effect of surface topography was studied by growing amorphous silicon on hybrid micro- and nanostructures, as well as planar hybrid. Compared with planar sample plates, micro- and nanostructures gave weaker and stronger signals, respectively. Different coating materials were tested by growing different thin film coatings on the same substrate. Good signals were obtained from titania and amorphous silicon coated sample plates, but not from alumina coated, silicon nitride coated, or uncoated sample plates. Overall, the strongest signals were obtained from oxygen plasma treated and amorphous silicon coated inorganic-organic hybrid, which was tested for peptide-, protein-, and drug molecule analysis. Peptides and drugs were analyzed with little interference at low masses, subfemtomole detection levels were achieved for des-arg(9)-bradykinin, and the sample plates were also suitable for ionization of small proteins.


Subject(s)
Nanostructures/chemistry , Nanostructures/ultrastructure , Peptides/chemistry , Silicon/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Adsorption , Materials Testing/methods , Protein Binding , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...