Materials (Basel) ; 16(13)2023 Jul 06.
Article in English | MEDLINE | ID: mdl-37445162

ABSTRACT

This study investigated the effects of antirotational titanium bases on the mechanical behavior of CAD/CAM titanium bases used for implant-supported prostheses. The aim was to assess the impact on the marginal fit, fatigue behavior, stress concentration, and fracture load of implant-supported CAD/CAM zirconia crowns. Forty titanium implants were divided into two groups: those with antirotational titanium bases (ARs) and those with rotational titanium bases (RTs). Torque loosening and vertical misfit were evaluated before and after cyclic fatigue testing (200 N, 2 Hz, 2 × 106 cycles). Fracture resistance was assessed using a universal testing machine (1 mm/min, 1000 kgf), and failed specimens were examined with microscopy. Three-dimensional models were created, and FEA was used to calculate stress. Statistical analysis was performed on the in vitro test data using two-way analysis of variance and Tukey's test (α = 0.5). Results show that the presence of an antirotational feature between the implant and titanium base reduced preload loss and stress concentration compared to rotational titanium bases. However, there were no differences in vertical misfit and resistance to compressive load.

2.
PLoS One ; 18(5): e0285421, 2023.
Article in English | MEDLINE | ID: mdl-37146083

ABSTRACT

This in-silico investigation evaluated the mechanical impact of Morse tape implant-abutment interface and retention system (with and without screw) and restorative materials (composite block and monolithic zirconia) by means of a three-dimensional finite element analysis (3D-FEA). Four 3D models were designed for the lower first molar. A dental implant (4.5 × 10 mm B&B Dental Implant Company) was digitized (micro CT) and exported to computer-aided design (CAD) software. Non-uniform rational B-spline surfaces were reconstructed, generating a 3D volumetric model. Four different models were generated with the same Morse-type connection, but with a different locking system (with and without active screw) and a different crown material made of composite block and zirconia. The D2 bone type, which contains cortical and trabecular tissues, was designed using data from the database. The implants were juxtaposed inside the model after Boolean subtraction. Implant placement depth was simulated for the implant model precisely at crestal bone level. Each acquired model was then imported into the finite element analysis (FEA) software as STEP files. The Von Mises equivalent strains were calculated for the peri-implant bone and the Von Mises stress for the prosthetic structures. The highest strain values in bone tissue occurred in the peri-implant bone interface and were comparable in the four implant models (8.2918e-004-8.6622e-004 mm/mm). The stress peak in the zirconia crown (64.4 MPa) was higher than in the composite crown (52.2 MPa) regardless of the presence of the prosthetic screw. The abutment showed the lowest stress peaks (99.71-92.28 MPa) when the screw was present (126.63-114.25 MPa). Based on this linear analysis, it is suggested that the absence of prosthetic screw increases the stress inside the abutment and implant, without effect on the crown and around the bone tissue. Stiffer crowns concentrate more stress on its structure, reducing the amount of stress on the abutment.


Subject(s)
Dental Implants , Finite Element Analysis , Stress, Mechanical , Crowns , Bone Screws , Dental Stress Analysis
3.
J Funct Biomater ; 14(3)2023 Mar 18.
Article in English | MEDLINE | ID: mdl-36976088

ABSTRACT

BACKGROUND: Recently several calcium silicate flowable sealers have been introduced as endodontic materials for the root canal. This clinical study tested the use of a new premixed calcium silicate bioceramic sealer in association with the Thermafil warm carrier-based technique (TF). Epoxy-resin-based sealer with the warm carrier-based technique was the control group. METHODOLOGY: Healthy consecutive patients (n = 85) requiring 94 root canal treatments were enrolled in this study and assigned to one filling group (Ceraseal-TF n = 47, AH Plus-TF n = 47) in accordance with operator training and best clinical practice. Periapical X-rays were taken preoperatively, after root canal filling and after 6, 12 and 24 months. Two evaluators blindly assessed the periapical index (PAI) and sealer extrusion in the groups (k = 0.90). Healing rate and survival rate were also evaluated. Chi-square tests was used to analyze significant differences between the groups. Multilevel analysis was performed to evaluate the factors associated with healing status. RESULTS: A total of 89 root canal treatments in 82 patients were analyzed at the end-line (24 months). The total drop-out was 3.6% (3 patients; 5 teeth). A total of 91.1% of healed teeth (PAI 1-2) was observed in Ceraseal-TF, with 88.6% in AH Plus-TF. No significant difference was observed on healing outcome and survival among the two filling groups (p > 0.05). Apical extrusion of the sealers occurred in 17 cases (19.0%). Of these, 6 occurred in Ceraseal-TF (13.3%) and 11 in AH Plus-TF (25.0%). Three Ceraseal extrusions were radiographically undetectable after 24 months. All the AH Plus extrusions did not change during the evaluation time. CONCLUSIONS: The combined use of the carrier-based technique and premixed CaSi-based bioceramic sealer showed clinical results comparable with carrier-based technique and epoxy-resin-based sealer. The radiographical disappearance of apically extruded Ceraseal is a possible event in the first 24 months.

4.
J Funct Biomater ; 14(2)2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36826908

ABSTRACT

This study evaluated the effect of pH and temperature on the ion (F- and Ca2+) release of a resin-based material containing alkaline fillers and a self-setting high-viscous glass ionomer cement. Disks were prepared according to manufacturers' instructions for both materials: the EF group (Equia Forte HT filling, GC) and the CN group (Cention N, Ivoclar). Specimens were immersed in 50 mL buffer solution with three different pHs (4.8, 6.8, and 8.8), and stored at 0°, 18°, 37°, and 44 °C. After 24 h, 7 d, and 28 d, cumulative F- and Ca2+ releases were analyzed by chromatography and mass spectrometry, and pH was measured. Both materials showed minimal changes in pH with final values after 28 d of 5.17 ± 0.56 for CN and 5.12 ± 0.24 for EF. In all experimental conditions, the percentages of ion release were higher for EF than for CF. In particular, both materials showed a significant difference in temperature in F- release. Regardless of the pH values, the highest Ca2+ ion release was after 28 days, with a significant difference in temperature for CN and EF. Within the limit of this study, the temperature storage influenced ion release and the high-viscous glass ionomer showed the maximum values.

5.
Dent Mater ; 39(1): 114-122, 2023 01.
Article in English | MEDLINE | ID: mdl-36566152

ABSTRACT

OBJECTIVE: This study aimed to evaluate the influence of new resin-based CAD-CAM implant-supported materials on posterior crown restoration stress and strain concentrations. METHODS: A previous 3D implant model was edited to receive a cement-retained posterior crown manufactured with different CAD/CAM materials (Estelite P Block, Estelite Block II or Estelite Layered Block). Each solid model was exported to the computer-aided engineering software and submitted to the finite element analysis of stress and strain. Material properties were assigned to each solid with isotropic and homogeneous behavior according to the manufacturer information. A vertical load of 600 N was applied in the occlusal region of the crown, via a simulated food bolus, and stress was calculated in Von Misses (σVM) for the implant, abutment and screw, Maximum (σMAX) Principal Stresses for the crown and microstrain for the bone. RESULTS: All simulated materials showed acceptable stresses levels with a similar stress pattern among the models. At the crown intaglio region and cement layer, however, differences were observed: Estelite P Block showed a lower tensile and shear stresses magnitude when compared to other resin-based materials with lower elastic modulus. SIGNIFICANCE: The stress effect of different resin-based CAD-CAM implant-supported crowns is predominant in the crown and cement layer, with Estelite P Block showing 7.4 % versus 9.3 % and 9.2 % for Estelite Block II and Estelite Layered Block of crown failure risk.


Subject(s)
Dental Implants , Dental Porcelain , Crowns , Dental Materials , Dental Cements , Computer-Aided Design , Dental Stress Analysis , Dental Prosthesis, Implant-Supported , Finite Element Analysis , Materials Testing , Dental Prosthesis Design
6.
Bioengineering (Basel) ; 9(5)2022 May 20.
Article in English | MEDLINE | ID: mdl-35621499

ABSTRACT

An in-depth evaluation of the mechanical and metallurgical properties of NiTi instruments is fundamental to assess their performance and to compare recently introduced instrument with widespread ones. According to this, since there are no data on this topic, the aim of the study was to mechanically and metallurgically evaluate an instrument recently introduced into the market (ZenFlex (ZF)), by comparing it with two well-known instruments with similar characteristics: Vortex Blue (VB) and EdgeSequel Sapphire (EES). According to this, 195 instruments were selected: 65 ZF, 65 VB and 65 EES. Each group was divided in subgroups according to the mechanical tests (i.e., cyclic fatigue resistance, torsional resistance and bending ability; (n = 20)) and the metallurgical test (differential scanning calorimetry (n = 5)). A scanning electron microscopy was performed to verify the causes of fracture after mechanical tests (cyclic fatigue and torsional tests). According to results, VB showed the highest flexibility and cyclic fatigue resistance in comparison to the other instruments, with a statistically significant difference (p < 0.05). Regarding torsional resistance, EES showed the lowest value of torque at fracture, with a statistically significant difference, whilst the comparison between ZF and VB showed no statistically significant difference (p > 0.05). DSC analysis pointed out that VB had the highest austenite start and finish temperatures, followed by ESS and then ZF. ESS sample showed the highest martensite start and finish temperatures followed by VB and ZF. Considering the results, it can be concluded that VB showed the best mechanical performance during static tests in comparison to ESS and ZF. This is fundamentally due to the interaction of parameters such as instrument design and heat-treatments that are able to enhance its mechanical performance.

7.
Polymers (Basel) ; 14(8)2022 Apr 07.
Article in English | MEDLINE | ID: mdl-35458251

ABSTRACT

The present investigation evaluated the effect of the combination of different dental filling materials in Class I cavities under occlusal loading using three-dimensional finite elements analysis (FEA). Six computer-generated and restored models of a lower molar were created in the CAD software and compared according to the biomechanical response during chewing load condition. Two adhesively bonded bulk restorative materials [bulk-fill resin composite (BF) or Alkasite (Alk)] were evaluated with or without the presence of a base material below (flowable resin composite or glass ionomer cement). A food bolus was placed on the occlusal surface mimicking the compressive occlusal load (600 N) during the static linear analysis. The maximum principal stress (tensile) was calculated as stress criteria in enamel, dentin and restoration. All models showed high stresses along the enamel/restoration margin with a similar stress trend for models restored with the same upper-layer material. Stress values up to 12.04 MPa (Alk) or up to 11.12 MPa (BF) were recorded at the enamel margins. The use of flexible polymeric or ionic base material in combination with bulk-fill resin composite or Alk did not reduce the stress magnitude in dentine and enamel. Class I cavities adhesively restored with bulk-fill resin composite showed lighter stress concentration as well as Alk. Therefore, adhesively bonded Alk restoration showed a promising mechanical behavior when used with different base materials or as a bulk restoration for posterior Class I cavity.

8.
Dent J (Basel) ; 10(1)2022 Jan 14.
Article in English | MEDLINE | ID: mdl-35049610

ABSTRACT

This study evaluated the influence of distal implants angulation and framework material in the stress concentration of an All-on-4 full-arch prosthesis. A full-arch implant-supported prosthesis 3D model was created with different distal implant angulations and cantilever arms (30° with 10-mm cantilever; 45° with 10-mm cantilever and 45° with 6-mm cantilever) and framework materials (Cobalt-chrome [CoCr alloy], Yttria-stabilized tetragonal zirconia polycrystal [Y-TZP] and polyetheretherketone [PEEK]). Each solid was imported to computer-aided engineering software, and tetrahedral elements formed the mesh. Material properties were assigned to each solid with isotropic and homogeneous behavior. The contacts were considered bonded. A vertical load of 200 N was applied in the distal region of the cantilever arm, and stress was evaluated in Von Misses (σVM) for prosthesis components and the Maximum (σMAX) and Minimum (σMIN) Principal Stresses for the bone. Distal implants angled in 45° with a 10-mm cantilever arm showed the highest stress concentration for all structures with higher stress magnitudes when the PEEK framework was considered. However, distal implants angled in 45° with a 6-mm cantilever arm showed promising mechanical responses with the lowest stress peaks. For the All-on-4 concept, a 45° distal implants angulation is only beneficial if it is possible to reduce the cantilever's length; otherwise, the use of 30° should be considered. Comparing with PEEK, the YTZP and CoCr concentrated stress in the framework structure, reducing the stress in the prosthetic screw.

9.
Polymers (Basel) ; 13(21)2021 Nov 05.
Article in English | MEDLINE | ID: mdl-34771387

ABSTRACT

Evidence regarding the effect of the onlay preparation design for different CAD/CAM restorative materials considering the preservation of cusps is lacking. Molars were 3D-modeled in four preparation designs for onlay restoration: traditional design with functional cusp coverage (TFC), non-retentive design with functional cusp coverage (NFC), traditional design with non-functional cusp coverage (TNFC) and non-retentive design with non-functional cusp coverage (NNFC). The restorations were simulated with two CAD/CAM restorative materials: LD-lithium disilicate (IPS e.max CAD) and RC-resin composite (GrandioBloc). A 100 N axial load was applied to the occlusal surface, simulating the centric contact point. Von Mises (VM) and maximum principal (Pmax) stress were evaluated for restorations, cement layer and dental substrate. The non-retentive preparation design reduced the stress concentration in the tooth structure in comparison to the conventional retentive design. For LD onlays, the stress distribution on the restoration intaglio surface showed that the preparation design, as well as the prepared cusp, influenced the stress magnitude. The non-retentive preparation design provided better load distribution in both restorative materials and more advantageous for molar structure. The resin composite restoration on thenon-functional cusp is recommended when the functional cusp is preserved in order to associate conservative dentistry and low-stress magnitude.

10.
Molecules ; 26(20)2021 Oct 10.
Article in English | MEDLINE | ID: mdl-34684695

ABSTRACT

The aim of this study was to evaluate the effect of biologically oriented preparation technique on the stress concentration of endodontically treated upper central incisors restored with zirconia crown (yttria-stabilized zirconia polycrystalline ceramic) through finite element analysis (FEA). Four models of maxillary central incisors containing enamel, dentin, periodontal ligament, cortical and medullary bone were created in CAD. Each model received a polymeric core-build up with nanofilled dental resin composite. The evaluated models were SM-preparation in shoulder 90°; CM-chamfer preparation; BOPT-biologically oriented preparation technique and BOPTB-BOPT preparation 1 mm below the cement-enamel junction. All models received zirconia crowns (5Y-TZP), fiberglass post and 1 mm ferrule. The models were imported into the analysis software with parameters for mechanical structural testing using the maximum principal stress and the tensile strength as the analysis criteria. Then, load of 150 N was applied at the cingulum with 45° slope to the long axis of the tooth, with the fixed base for each model. The type of marginal preparation affected the stresses concentration in endodontically treated teeth and in the zirconia crown margin. Considering the stress magnitude only, BOPT is a viable option for anterior monolithic zirconia crowns; however, with the highest stress magnitude at the restoration margin.


Subject(s)
Ceramics/chemistry , Composite Resins/chemistry , Crowns , Finite Element Analysis/standards , Incisor/surgery , Tooth, Nonvital/surgery , Zirconium/chemistry , Glass/chemistry , Humans , Incisor/anatomy & histology , Incisor/drug effects , Stress, Mechanical , Tensile Strength
11.
Dent Mater ; 37(11): 1688-1697, 2021 11.
Article in English | MEDLINE | ID: mdl-34497022

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the influence of three different dental implant neck geometries, under a combined compressive/shear load using finite element analysis (FEA). The implant neck was positioned in D2 quality bone at the crestal level or 2 mm below. METHODS: One dental implant (4.2 × 9 mm) was digitized by reverse engineering techniques using micro CT and imported into Computer Aided Design (CAD) software. Non-uniform rational B-spline surfaces were reconstructed, generating a 3D volumetric model similar to the digitized implant. Three different models were generated with different implant neck configurations, namely 0°, 10° and 20°. D2 quality bone, composed of cortical and trabecular structure, was modeled using data from CT scans. The implants were included in the bone model using a Boolean operation. Two different fixture insertion depths were simulated for each implant: 2 mm below the crestal bone and exactly at the level of the crestal bone. The obtained models were imported to FEA software in STEP format. Von Mises equivalent strains were analyzed for the peri-implant D2 bone type, considering the magnitude and volume of the affected surrounding cortical and trabecular bone. The highest strain values in both cortical and trabecular tissue at the peri-implant bone interface were extracted and compared. RESULTS: All implant models were able to distribute the load at the bone-implant contact (BIC) with a similar strain pattern between the models. At the cervical region, however, differences were observed: the models with 10° and 20° implant neck configurations (Model B and C), showed a lower strain magnitude when compared to the straight neck (Model A). These values were significantly lower when the implants were situated at crestal bone levels. In the apical area, no differences in strain values were observed. SIGNIFICANCE: The implant neck configuration influenced the strain distribution and magnitude in the cortical bone and cancellous bone tissues. To reduce the strain values and improve the load dissipation in the bone tissue, implants with 10° and 20 neck configuration should be preferred instead of straight implant platforms.


Subject(s)
Dental Implants , Computer-Aided Design , Dental Stress Analysis , Finite Element Analysis , Stress, Mechanical
12.
Craniomaxillofac Trauma Reconstr ; 14(3): 254-260, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34471482

ABSTRACT

BACKGROUND/AIMS: There is a lack of data regarding the influence of different laminates for mouthguard reinforcement in the mechanical response during an impact in the orofacial region. The aim of this study was to verify the influence of the laminate framework on the stresses and strains of the anterior teeth and displacement of ethylene-vinyl acetate (EVA) custom-made mouthguards during a simulated impact. The null hypotheses was that the different laminates reinforcement would present the similar effect in maxillary structures, regardless the elastic modulus. METHODS: A finite element model of human maxillary central incisors with an antagonist contact was used. A linear quasi-static analysis was used to simulate the force exerted during an impact. A total of 5 different layers were simulated inside the mouthguard at the labial portion according to the Elastic Modulus 1 MPa (Extremely flexible), 9 GPa (Low modulus reinforcement), 18 GPa (Without reinforcement), 50 GPa (Flexible alloy), 100 GPa (Titanium alloy) and 200 GPa (Hard material). The results were evaluated by means of Maximum Principal Stress (in the tooth and bone), Microstrain (periodontal ligament) and Displacement (mouthguard) criteria. RESULTS: The elastic modulus of the material inside the MG influenced the stress distribution on the enamel buccal face. However, it did not affect the bone tissue stress, periodontal ligament strain or root dentin tissue stress. Conclusion: The use of reinforcement inside the custom-made mouthguard can modify the stress generated in the enamel buccal surface without improvement to the root dentin, periodontal ligament or bone tissue.

13.
Am J Dent ; 34(3): 157-162, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34143586

ABSTRACT

PURPOSE: To evaluate the effect of different substrate stiffness [sound dentin (SD), resin composite core (RC) or metal core (MC)] on the stress distribution of a zirconia posterior three-unit fixed partial denture (FPD). METHODS: The abutment teeth (first molar and first premolar) were modeled, containing 1.5 mm of axial reduction, and converging axial walls. A static structural analysis was performed using a finite element method and the maximum principal stress criterion to analyze the fixed partial denture (FPD) and the cement layers of both abutment teeth. The materials were considered isotropic, linear, elastic, homogeneous and with bonded contacts. An axial load (300 N) was applied to the occlusal surface of the second premolar. RESULTS: The region of the prosthetic connectors showed the highest tensile stress magnitude in the FPD structure depending on the substrate stiffness with different core materials. The highest stress peak was observed with the use of MC (116.4 MPa) compared to RC and SD. For the cement layer, RC showed the highest values in the molar abutment (14.7 MPa) and the highest values for the premolar abutment (14.4 MPa) compared to SD (14.1 and 13.4 MPa) and MC (13.8 and 13.3 MPa). Both metal core and resin composite core produced adequate stress concentration in the zirconia fixed partial denture during the load incidence. However, more flexible substrates, such as composite cores, can increase the tensile stress magnitude on the cement. CLINICAL SIGNIFICANCE: The present study shows that the choice of the cast core and metallic post by the resin composite core and fiberglass post did not improve the biomechanical behavior of the FPD. This choice must be performed based on clinical criteria (other) than mechanical.


Subject(s)
Denture, Partial, Fixed , Zirconium , Dental Stress Analysis , Finite Element Analysis , Stress, Mechanical
14.
Materials (Basel) ; 14(9)2021 May 01.
Article in English | MEDLINE | ID: mdl-34062936

ABSTRACT

This study evaluated the stress distribution in five different class II cavities of premolar models restored with conventional or bulk-fill flowable composite by means of finite element analysis (FEA) under shrinkage and occlusal loading. An upper validated premolar model was imported in the software, and five class II cavities with different occlusal extensions and dimensions were prepared: horizontal cavity on the mesial surface (horizontal slot), mesio-occlusal cavity, mesial cavity (vertical slot), tunnel type cavity and direct access cavity. The models were restored with conventional or bulk-fill flowable resin composite. The tested materials were considered as homogeneous, linear, and isotropic. The Maximum Principal Stress criteria was chosen to evaluate the tensile stress results. The lowest shrinkage stress value was observed in the direct access cavity restored with bulk-fill flowable resin composite (36.12 MPa). The same cavity, restored with conventional composite showed a score of 36.14 MPa. The horizontal slot cavity with bulk-fill flowable showed a score of 46.71 MPa. The mesio-occlusal cavity with bulk-fill flowable had a score of 53.10 MPa, while with conventional composite this was 55.35 MPa. Higher shrinkage stress was found in the vertical slot cavity with conventional resin 56.14 MPa, followed by the same cavity with bulk-fill flowable 56.08 MPa. Results indicated that the use of bulk-fill flowable composite resin more significantly decreased the polymerization shrinkage stress magnitude. The larger the cavity and the volume of material necessary to restore the tooth, the greater the residual stress on enamel and dentin tissue.

15.
Materials (Basel) ; 14(8)2021 Apr 12.
Article in English | MEDLINE | ID: mdl-33921347

ABSTRACT

This study evaluated the effect of the combination of three different onlay preparation designs and two restorative materials on the stress distribution, using 3D-finite element analysis. Six models of first lower molars were created according to three preparation designs: non-retentive (nRET), traditional with occlusal isthmus reduction (IST), and traditional without occlusal isthmus reduction (wIST); and according to two restorative materials: lithium-disilicate (LD) and nanoceramic resin (NR). A 600 N axial load was applied at the central fossa. All solids were considered isotropic, homogeneous, and linearly elastic. A static linear analysis was performed, and the Maximum Principal Stress (MPS) criteria were used to evaluate the results and compare the stress in MPa on the restoration, cement layer, and tooth structure (enamel and dentin). A novel statistical approach was used for quantitative analysis of the finite element analysis results. On restoration and cement layer, nRET showed a more homogeneous stress distribution, while the highest stress peaks were calculated for LD onlays (restoration: 69-110; cement layer: 10.2-13.3). On the tooth structure, the material had more influence, with better results for LD (27-38). It can be concluded that nRET design showed the best mechanical behavior compared to IST and wIST, with LD being more advantageous for tooth structure and NR for the restoration and cement layer.

16.
Polymers (Basel) ; 13(5)2021 Feb 28.
Article in English | MEDLINE | ID: mdl-33670991

ABSTRACT

BACKGROUND: This study evaluated the effect of interim restorative materials (acrylic resin (AR), resin composite (RC) or polyetheretherketone (PEEK) for dental computer-aided design/computer-aided manufacturing (CAD/CAM)) on the stress distribution of a posterior three-unit fixed partial denture. METHODS: The abutment teeth (first molar and first premolar) were modeled using the BioCAD protocol containing 1.5 mm of axial reduction and converging axial walls. A static structural analysis was performed in the computer-aided engineering software, and the Maximum Principal Stress criterion was used to analyze the prosthesis and the cement layers of both abutment teeth. The materials were considered isotropic, linearly elastic, homogeneous and with bonded contacts. An axial load (600 N) was applied to the occlusal surface of the second premolar. RESULTS: Regardless of the restorative material, the region of the prosthetic connectors showed the highest tensile stress magnitude. The highest stress peak was observed with the use of RC (129 MPa) compared to PEEK and AR. For the cement layers, RC showed the lowest values in the occlusal region (7 MPa) and the highest values for the cervical margin (14 MPa) compared to PEEK (21 and 12 MPa) and AR (21 and 13 MPa). CONCLUSIONS: Different interim restorative materials for posterior fixed partial dentures present different biomechanical behavior. The use of resin composite can attenuate the stress magnitude on the cement layer, and the use of acrylic resin can attenuate the stress magnitude on the connector region.

17.
Polymers (Basel) ; 12(8)2020 Aug 16.
Article in English | MEDLINE | ID: mdl-32824363

ABSTRACT

The aim of the current work was to analyze the influence of the ferrule effect for hybrid composite endodontic post designs consisting of carbon (C) and glass (G) fiber-reinforced polyetherimide (PEI), in upper canine teeth. Starting from theoretical designs of C-G/PEI hybrid composite posts with different Young's moduli (Post A-57.7 GPa, Post B-31.6 GPa, Post C-graduated from 57.7 to 9.0 GPa in the coronal-apical direction) in endodontically treated anterior teeth, the influence of the ferrule effect was determined through finite element analysis (FEA). On the surface of the crown, a load of 50 N was applied at 45° to the longitudinal axis of the tooth. Maximum principal stresses were evaluated along the C-G/PEI post as well as at the interface between the surrounding tooth structure and the post. Maximum stress values were lower than those obtained for the corresponding models without a ferrule. The presence of a ferrule led to a marked decrease of stress and gradients especially for posts A and B. A less marked effect was globally found for Post C, except in a cervical margin section along a specific direction, where a significant decrease of the stress was probably due to local geometric features, compared to the model without a ferrule. The presence of a ferrule did not generally provide a marked benefit in the case of the graduated Post C, in comparison to other C-G/PEI posts. The outcomes suggest how such a hybrid composite post alone should be sufficient to optimize the stress distribution, dissipating stress from the coronal to the apical end.

18.
Article in English | MEDLINE | ID: mdl-32517097

ABSTRACT

The current study aimed to evaluate the mechanical behavior of two different maxillary prosthetic rehabilitations according to the framework design using the Finite Element Analysis. An implant-supported full-arch fixed dental prosthesis was developed using a modeling software. Two conditions were modeled: a conventional casted framework and an experimental prosthesis with customized milled framework. The geometries of bone, prostheses, implants and abutments were modeled. The mechanical properties and friction coefficient for each isotropic and homogeneous material were simulated. A load of 100 N load was applied on the external surface of the prosthesis at 30° and the results were analyzed in terms of von Mises stress, microstrains and displacements. In the experimental design, a decrease of prosthesis displacement, bone strain and stresses in the metallic structures was observed, except for the abutment screw that showed a stress increase of 19.01%. The conventional design exhibited the highest stress values located on the prosthesis framework (29.65 MPa) between the anterior implants, in comparison with the experimental design (13.27 MPa in the same region). An alternative design of a stronger framework with lower stress concentration was reported. The current study represents an important step in the design and analysis of implant-supported full-arch fixed dental prosthesis with limited occlusal vertical dimension.


Subject(s)
Dental Prosthesis , Biomechanical Phenomena , Computer Simulation , Finite Element Analysis , Stress, Mechanical
19.
Restor Dent Endod ; 44(3): e33, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31485429

ABSTRACT

OBJECTIVES: To evaluate the influence of the restorative technique on the mechanical response of endodontically-treated upper premolars with mesio-occluso-distal (MOD) cavity. MATERIALS AND METHODS: Forty-eight premolars received MOD preparation (4 groups, n = 12) with different restorative techniques: glass ionomer cement + composite resin (the GIC group), a metallic post + composite resin (the MP group), a fiberglass post + composite resin (the FGP group), or no endodontic treatment + restoration with composite resin (the CR group). Cusp strain and load-bearing capacity were evaluated. One-way analysis of variance and the Tukey test were used with α = 5%. Finite element analysis (FEA) was used to calculate displacement and tensile stress for the teeth and restorations. RESULTS: MP showed the highest cusp (p = 0.027) deflection (24.28 ± 5.09 µm/µm), followed by FGP (20.61 ± 5.05 µm/µm), CR (17.72 ± 6.32 µm/µm), and GIC (17.62 ± 7.00 µm/µm). For load-bearing, CR (38.89 ± 3.24 N) showed the highest, followed by GIC (37.51 ± 6.69 N), FGP (29.80 ± 10.03 N), and MP (18.41 ± 4.15 N) (p = 0.001) value. FEA showed similar behavior in the restorations in all groups, while MP showed the highest stress concentration in the tooth and post. CONCLUSIONS: There is no mechanical advantage in using intraradicular posts for endodontically-treated premolars requiring MOD restoration. Filling the pulp chamber with GIC and restoring the tooth with only CR showed the most promising results for cusp deflection, failure load, and stress distribution.

20.
Am J Dent ; 32(4): 165-168, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31436935

ABSTRACT

PURPOSE: To evaluate the biomechanical behavior of monolithic ceramic crowns with functional elasticity gradient. METHODS: Using a CAD software, a lower molar received a full-crown preparation (1.5 mm occlusal and axial reduction). The monolithic crown was modeled with a resin cement layer of 0.1 mm. Four groups were distributed according to the full crown elastic modulus (E) :(a) Bioinspired crown with decreasing elastic modulus (from 90 to 30GPa); (b) Crown with increasing elastic modulus (from 30 to 90 GPa); (c) Rigid crown (90 GPa) and (d) Flexible crown (30 GPa). The model was exported to the analysis software and meshed into 385.240 tetrahedral elements and 696.310 nodes. Materials were considered isotropic, linearly elastic, and homogeneous, with ideal contacts. A 300-N load was applied at the occlusal surface and the base of the model was fixed in all directions. The results were required in maximum principal stress criterion. RESULTS: Crowns consisting of layers with increasing elastic modulus presented intermediate results between the rigid and flexible crowns. Compared to the flexible crown, the bioinspired crown showed acceptable stress distribution across the structure with lower stress concentration in the tooth. In dental crowns the multilayer structure with functional elasticity gradient modifies the stress distribution in the restoration, with promising results for bioinspired design. CLINICAL SIGNIFICANCE: The manufacturing of posterior crowns with functional elasticity gradient should be considered due to its promising results on the stress concentration behavior.


Subject(s)
Crowns , Resin Cements , Dental Porcelain , Dental Prosthesis Design , Dental Stress Analysis , Elastic Modulus , Elasticity , Materials Testing , Molar , Stress, Mechanical