Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
JSES Int ; 6(4): 615-622, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35813148

ABSTRACT

Background: Shoulder pain and loss of function are classically associated with rotator cuff tears, while paresthesia of the hand is not. We noted anecdotally that paresthesia of the arm was common in patients presenting with rotator cuff tears. The purpose of this study was to determine the prevalence and magnitude of hand paresthesia, its relationship to pain, and how surgery affected these symptoms. Methods: This prospective cross-sectional study assessed the prevalence and magnitude of shoulder pain and hand numbness and tingling (as assessed by 2 questions from the modified Boston Carpal Tunnel Questionnaire) preoperatively and at 1 week, 6 weeks, 12 weeks, and 6 months postoperatively among 213 consecutive patients who presented for and underwent arthroscopic rotator cuff repair. Results: The preoperative levels of prevalence and severity of shoulder pain during rest, overhead activities, and sleep improved by 52%, 22%, and 34%, respectively, compared with those by 6 months postoperatively (P < .05). Seventy-five patients (33%) reported hand paresthesia before surgery. There was a 50% and 60% reduction in the severity of hand tingling and numbness, respectively, by 1 week after surgery (P < .05). The preoperative level of hand numbness (Wald statistic; W = 20) and whether the patient's shoulder problem was caused by a specific injury (W = 6) were predictive of the presence of hand numbness at 6 months after surgery (P < .05). Conclusion: This study showed that many patients who undergo rotator cuff repairs present with hand paresthesia that is associated with their shoulder pain. The prevalence and severity of shoulder pain and hand numbness and tingling improved postoperatively.

2.
Orthop J Sports Med ; 10(6): 23259671221105080, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35747364

ABSTRACT

Background: Favorable outcomes have been reported regarding postoperative shoulder pain and function after repair of anteroinferior (Bankart) glenohumeral labral tears. However, the outcomes of patients after repair of isolated superior labral anterior-posterior (SLAP) tears are a contentious topic. The authors have also anecdotally noted that patients evaluated with labral tears complained of numbness and tingling in their ipsilateral hand. Purpose: To determine if there is a difference in the temporal outcomes of shoulder pain and hand paresthesia in patients with SLAP tears versus Bankart tears after arthroscopic repair. Study Design: Cohort study; Level of evidence, 3. Methods: Included were 66 consecutive patients who underwent arthroscopic labral repair at a single institution between August 2018 and February 2021. The prevalence and magnitude of shoulder pain as well as numbness and tingling of the hand were assessed using questions from the L'Insalata Shoulder Questionnaire and the Boston Carpal Tunnel Questionnaire preoperatively and at 1 week, 6 weeks, 12 weeks, and 6 months after surgery. Results: Preoperatively, patients with SLAP lesions reported a higher prevalence of shoulder pain during sleep compared with those with Bankart tears (P < .05). Postoperatively, patients who underwent SLAP repair reported a larger proportion and more severe magnitude of shoulder pain during rest, overhead activities, and sleep compared with those who underwent Bankart repair (P < .05). Only patients who underwent Bankart repair reported improvements in the prevalence and magnitude of their shoulder pain during rest, overhead activities, and sleep by 6 months postoperatively compared with preoperative levels (P < .05). Preoperatively, 30% of patients with Bankart repairs and 40% of patients with SLAP repairs reported hand tingling, while 35% and 50%, respectively, reported hand numbness. The prevalence and magnitude of hand tingling and numbness were not significantly different between groups at any time point. Conclusion: Study results indicated that patients who underwent SLAP repair experienced worse shoulder pain outcomes compared with those who underwent Bankart repair using the same anchor and surgical technique. Only patients who underwent Bankart repair reported improvements in their hand numbness after surgery. Therefore, labral tear location does matter with respect to shoulder pain and hand numbness.

3.
Shoulder Elbow ; 12(1): 18-23, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32010229

ABSTRACT

INTRODUCTION: Shear wave elastography ultrasound is a relatively new technique that evaluates the tissue elasticity by applying an acoustic radiation force impulse. It is undetermined how reliable this modality is in assessing rotator cuff tendons. The aim of this study, therefore, was to evaluate the reliability of shear wave elastography ultrasound to assess the stiffness of normal and tendinopathic supraspinatus tendons. METHODS: An inter- and intra-rater reliability trial was carried out using shear wave elastography to assess the supraspinatus tendon at its distal insertion, by measuring shear wave velocity and elasticity. Twenty participants with a mean age of 37 (21-69) years old were evaluated. Ten subjects with normal supraspinatus tendon and 10 subjects with tendinopathic tendon were selected. The Virtual Touch Imaging Quantification program was used to generate the acoustic radiation force impulse and to obtain the elastography data. Three raters with different experience in conventional ultrasound were used for the inter-rater trial in normal tendons and the most experienced rater examined all subjects for the intra-rater reliability evaluation. Each rater obtained three readings in three different examinations per subject over a one-week period. RESULTS: The mean (±SEM) shear wave velocity for the normal supraspinatus tendon was 9.96 ± 0.02 m/s (=297 kPa), while in the tendinopathic supraspinatus tendon was 8.3 ± 0.2 m/s (=207 kPa) (p < 0.001). The intra-rater trial agreement was excellent, with an intraclass correlation coefficient = 0.96. In the inter-rater testing, the mean shear wave velocity in normal tendons was 9.90 ± 0.07 m/s (=294 kPa), with intraclass correlation coefficient = 0.45. CONCLUSION: Shear wave elastography ultrasound was able to show that tendinopathic tendons were less stiff than normal tendons. It was a reliable imaging technique to assess the supraspinatus tendon, especially when used by a single experienced musculoskeletal sonographer.

4.
Shoulder Elbow ; 11(2 Suppl): 48-55, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31447945

ABSTRACT

The aims of this study were to identify the common components of the Minimum Data Set (MDS) of current national shoulder arthroplasty registries that could be pooled for analysis; and to determine whether further harmonisation of data collection across these registries would be feasible. Copies of primary shoulder arthroplasty MDS forms, annual reports, and other publications from national shoulder arthroplasty registries were identified using internet search engines up to November 2016. Data relating to local or regional registries was excluded. There were nine national shoulder arthroplasty registries reporting a total of 97,388 primary shoulder replacements. All minimum data sets included patient identifiers, date of surgery, implant identification, laterality of surgery, indication and mode of implant fixation. At least 6 registries had common options within the categories of indication, implant fixation and previous operations. Most discrepancies were seen in categories for additional interventions, outcome measures, and intra-operative complications. As numbers within individual registries are relatively small, international collaboration would harness the global strength of knowledge and experience in shoulder replacement. Several similarities were identified between the current national registries that could become unified with only minor changes by a few registries, highlighting the potential feasibility of MDS harmonisat.

SELECTION OF CITATIONS
SEARCH DETAIL
...