1.
AAPS PharmSciTech ; 10(1): 252-7, 2009.
Article in English | MEDLINE | ID: mdl-19291411

ABSTRACT

The abbreviated impactor measurement (AIM) concept is a potential solution to the labor-intensive full-resolution cascade impactor (CI) methodology for inhaler aerosol aerodynamic particle size measurement. In this validation study, the effect of increasing the internal dead volume on determined mass fractions relating to aerodynamic particle size was explored with two abbreviated impactors both based on the Andersen nonviable cascade impactor (ACI) operating principle (Copley fast screening Andersen impactor [C-FSA] and Trudell fast screening Andersen impactor [T-FSA]). A pressurized metered dose inhaler-delivered aerosol producing liquid ethanol droplets after propellant evaporation was chosen to characterize these systems. Measures of extrafine, fine, and coarse particle mass fractions from the abbreviated systems were compared with corresponding data obtained by a full-resolution ACI. The use of liquid ethanol-sensitive filter paper provided insight by rendering locations visible where partly evaporated droplets were still present when the "droplet-producing" aerosol was sampled. Extrafine particle fractions based on impactor-sized mass were near equivalent in the range 48.6% to 54%, comparing either abbreviated system with the benchmark ACI-measured data. The fine particle fraction of the impactor-sized mass determined by the T-FSA (94.4 +/- 1.7%) was greater than using the C-FSA (90.5 +/- 1.4%) and almost identical with the ACI-measured value (95.3 +/- 0.4%). The improved agreement between T-FSA and ACI is likely the result of increasing the dead space between the entry to the induction port and the uppermost impaction stage, compared with that for the C-FSA. This dead space is needed to provide comparable conditions for ethanol evaporation in the uppermost parts of these impactors.


Subject(s)
Anti-Asthmatic Agents/chemistry , Beclomethasone/chemistry , Ethanol/chemistry , Materials Testing/instrumentation , Metered Dose Inhalers , Solvents/chemistry , Technology, Pharmaceutical/instrumentation , Administration, Inhalation , Aerosols , Anti-Asthmatic Agents/administration & dosage , Beclomethasone/administration & dosage , Chemistry, Pharmaceutical , Equipment Design , Particle Size , Pressure , Reproducibility of Results , Volatilization
2.
AAPS PharmSciTech ; 10(1): 243-51, 2009.
Article in English | MEDLINE | ID: mdl-19280348

ABSTRACT

The abbreviated impactor measurement concept is a potential improvement to the labor-intensive full-resolution cascade impactor methodology for inhaler aerosol aerodynamic particle size distribution (APSD) measurement by virtue of being simpler and therefore quicker to execute. At the same time, improved measurement precision should be possible by eliminating stages upon which little or no drug mass is collected. Although several designs of abbreviated impactor systems have been developed in recent years, experimental work is lacking to validate the technique with aerosols produced by currently available inhalers. In part 1 of this two-part article that focuses on aerosols produced by pressurized metered dose inhalers (pMDIs), the evaluation of two abbreviated impactor systems (Copley fast screening Andersen impactor and Trudell fast screening Andersen impactor), based on the full-resolution eight-stage Andersen nonviable cascade impactor (ACI) operating principle, is reported with a formulation producing dry particles. The purpose was to investigate the potential for non-ideal collection behavior associated with particle bounce in relation to internal losses to surfaces from which particles containing active pharmaceutical ingredient are not normally recovered. Both abbreviated impactors were found to be substantially equivalent to the full-resolution ACI in terms of extra-fine and fine particle and coarse mass fractions used as metrics to characterize the APSD of these pMDI-produced aerosols when sampled at 28.3 L/min, provided that precautions are taken to coat collection plates to minimize bounce and entrainment.


Subject(s)
Materials Testing/instrumentation , Metered Dose Inhalers , Respiratory System Agents/chemistry , Technology, Pharmaceutical/instrumentation , Administration, Inhalation , Aerosols , Equipment Design , Particle Size , Pressure , Reproducibility of Results , Respiratory System Agents/administration & dosage