Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Infection ; 50(3): 625-633, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34689310

ABSTRACT

BACKGROUND: The accuracy and reliability of rapid diagnostic tests are critical for monitoring and diagnosing SARS-CoV-2 infection in the general population. This study aimed to evaluate the analytical performance of the BIOSYNEX COVID-19 Ag BSS (Biosynex Swiss SA, Fribourg, Switzerland) antigen rapid diagnostic test (BIOSYNEX Ag-RDT), which targets the SARS-CoV-2 N-nucleocapsid protein for the diagnosis of COVID-19. The Ag-RDT was compared with a real-time RT-PCR (rtRT-PCR) as gold standard for performance measurement. METHODS: Two nasopharyngeal flocked swabs were prospectively collected simultaneously in March and April 2021 from 967 individuals aged ≥ 18 years tested for SARS-CoV-2 in two private laboratories, Paris, France. RESULTS: Overall, the Ag-RDT demonstrated high sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 81.8%, 99.6%, 96.6%, and 97.5%, respectively. The agreement (97.0%), reliability assessed using Cohen's κ-coefficient (0.87), and accuracy evaluated using Youden index (J) (81.6%) in detecting SARS-CoV-2 were high. The analytical performance of the Ag-RDT remained high when there was significant viral shedding (i.e., N gene Ct values ≤ 33 on reference RT-PCR). The sensitivity was only 55.2% in case of low or very low viral excretion (Ct > 33). CONCLUSIONS: The BIOSYNEX Ag-RDT is a promising, potentially simple diagnostic tool, especially in symptomatic COVID-19 patients with substantial viral excretion in the nasopharynx.


Subject(s)
COVID-19 , Antigens, Viral , COVID-19/diagnosis , France , Humans , Nasopharynx , Point-of-Care Systems , Prospective Studies , Real-Time Polymerase Chain Reaction , Reproducibility of Results , SARS-CoV-2/genetics , Sensitivity and Specificity
2.
Diagnostics (Basel) ; 11(12)2021 Nov 27.
Article in English | MEDLINE | ID: mdl-34943454

ABSTRACT

Due to their ease-of-use, lateral flow assay SARS-CoV-2 antigen-detecting rapid diagnostic tests could be suitable candidates for antigen-detecting rapid diagnostic self-test (Ag-RDST). We evaluated the practicability of the Ag-RDST BIOSYNEX Antigen Self-Test COVID-19 Ag+ (Biosynex Swiss SA, Freiburg, Switzerland), using self-collected nasal secretions from the turbinate medium (NMT), in 106 prospectively included adult volunteers living in Paris, France. The majority of the participants correctly understood the instructions for use (94.4%; 95% confidence interval (CI): 88.3-97.4), showing a great ability to perform the entire self-test procedure to obtain a valid and interpretable result (100%; 95% CI: 96.5-100), and demonstrated the ability to correctly interpret test results (96.2%; 95% CI: 94.2-97.5) with a high level of general satisfaction. About one in eight participants (# 15%) needed verbal help to perform or interpret the test, and only 3.8% of test results were misinterpreted. By reference to multiplex real-time RT-PCR, the Ag-RDST showed 90.9% and 100% sensitivity and specificity, respectively, and high agreement (98.1%), reliability (0.94), and accuracy (90.9%) to detect SARS-CoV-2 antigen. Taken together, our study demonstrates the high usability and accuracy of BIOSYNEX Antigen Self-Test COVID-19 Ag+ for supervised self-collected NMT sampling in an unselected adult population living in France.

SELECTION OF CITATIONS
SEARCH DETAIL
...