Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
Am J Physiol Heart Circ Physiol ; 325(6): H1279-H1289, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37773058

ABSTRACT

Congenital long QT syndrome (LQTS) carries an increased risk for syncope and sudden death. QT prolongation promotes ventricular extrasystoles, which, in the presence of an arrhythmia substrate, might trigger ventricular tachycardia degenerating into fibrillation. Increased electrical heterogeneity (dispersion) is the suggested arrhythmia substrate in LQTS. In the most common subtype LQT1, physical exercise predisposes for arrhythmia and spatiotemporal dispersion was therefore studied in this context. Thirty-seven patients (57% on ß-blockers) and 37 healthy controls (mean age, 31 vs. 35; range, 6-68 vs. 6-72 yr) performed an exercise test. Frank vectorcardiography was used to assess spatiotemporal dispersion as Tampl, Tarea, the ventricular gradient (VG), and the Tpeak-end interval from 10-s signal averages before and 7 ± 2 min after exercise; during exercise too much signal disturbance excluded analysis. Baseline and maximum heart rates as well as estimated exercise intensity were similar, but heart rate recovery was slower in patients. At baseline, QT and heart rate-corrected QT (QTcB) were significantly longer in patients (as expected), whereas dispersion parameters were numerically larger in controls. After exercise, QTpeakcB and Tpeak-endcB increased significantly more in patients (18 ± 23 vs. 7 ± 10 ms and 12 ± 17 vs. 2 ± 6 ms; P < 0.001 and P < 0.01). There was, however, no difference in the change in Tampl, Tarea, and VG between groups. In conclusion, although temporal dispersion of repolarization increased significantly more after exercise in patients with LQT1, there were no signs of exercise-induced increase in global dispersion of action potential duration and morphology. The arrhythmia substrate/mechanism in LQT1 warrants further study.NEW & NOTEWORTHY Physical activity increases the risk for life-threatening arrhythmias in LQTS type 1 (LQT1). The arrhythmia substrate is presumably altered electrical heterogeneity (a.k.a. dispersion). Spatiotemporal dispersion parameters were therefore compared before and after exercise in patients versus healthy controls using Frank vectorcardiography, a novelty. Physical exercise prolonged the time between the earliest and latest complete repolarization in patients versus controls, but did not increase parameters reflecting global dispersion of action potential duration and morphology, another novelty.


Subject(s)
Long QT Syndrome , Romano-Ward Syndrome , Humans , Adult , Electrocardiography , Long QT Syndrome/diagnosis , Vectorcardiography , Exercise Test , Heart Ventricles , Exercise/physiology
2.
Physiol Rep ; 10(21): e15487, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36324292

ABSTRACT

Hysteresis, a ubiquitous regulatory phenomenon, is a salient feature of the adaptation of ventricular repolarization duration to heart rate (HR) change. We therefore compared the QT interval adaptation to rapid HR increase in patients with the long QT syndrome type 1 (LQT1) versus healthy controls because LQT1 is caused by loss-of-function mutations affecting the repolarizing potassium channel current IKs , presumably an important player in QT hysteresis. The study was performed in an outpatient hospital setting. HR was increased in LQT1 patients and controls by administering an intravenous bolus of atropine (0.04 mg/kg body weight) for 30 s. RR and QT intervals were recorded by continuous Frank vectorcardiography. Atropine induced transient expected side effects but no adverse arrhythmias. There was no difference in HR response (RR intervals) to atropine between the groups. Although atropine-induced ΔQT was 48% greater in 18 LQT1 patients than in 28 controls (p < 0.001), QT adaptation was on average 25% faster in LQT1 patients (measured as the time constant τ for the mono-exponential function and the time for 90% of ΔQT; p < 0.01); however, there was some overlap between the groups, possibly a beta-blocker effect. The shorter QT adaptation time to atropine-induced HR increase in LQT1 patients on the group level corroborates the importance of IKs in QT adaptation hysteresis in humans and shows that LQT1 patients have a disturbed ultra-rapid cardiac memory. On the individual level, the QT adaptation time possibly reflects the effect-size of the loss-of-function mutation, but its clinical implications need to be shown.


Subject(s)
Romano-Ward Syndrome , Humans , Romano-Ward Syndrome/diagnosis , Romano-Ward Syndrome/genetics , Heart Rate/physiology , Atropine/pharmacology , Adaptation, Physiological , Heart , Electrocardiography
3.
J Electrocardiol ; 68: 90-100, 2021.
Article in English | MEDLINE | ID: mdl-34411881

ABSTRACT

BACKGROUND: Regional differences in ventricular activation sequence and action potential duration and morphology result in dispersion in ventricular repolarization (VR). VR dispersion is a key factor in arrhythmogenesis. We studied the adaptation of global VR dispersion in humans during normal and abnormal ventricular activation, and the relation to the QT adaptation (hysteresis). METHODS: We measured global VR dispersion as T amplitude, T area, and ventricular gradient (VG), using continuous Frank vectorcardiography, in response to abrupt and sustained atrial (AP) or ventricular pacing (VP) aiming at 120 bpm, in 21 subjects with permanent pacemakers. RESULTS: Following pacing start, VR adaptation showed an initially rapid and complex tri-phasic pattern, most pronounced for T amplitude. There were major differences in the patterns of VR dispersion adaptation following abrupt AP vs VP, confirming that the adaptation pattern is activation dependent. In response to AP, an instantaneous decrease in VR dispersion occurred, followed by an increase and then a slow decrease, all at a lower level than baseline. In contrast, following VP there was an immediate increase to ~4× baseline in T amplitude and T area (but not in VG), with a subsequent biphasic adaptation lasting longer during VP than AP. The initial rapid changes occurred within the time for QT adaptation to reach steady-state. CONCLUSIONS: Our results corroborate and expand data from animal and invasive human studies, showing similarities of the adaptation pattern on different scales. The initial rapidly changing VR adaptation phase presumably reflects a window of increased vulnerability to arrhythmias.


Subject(s)
Adaptation, Physiological , Electrocardiography , Animals , Arrhythmias, Cardiac , Heart Rate , Heart Ventricles , Humans , Vectorcardiography
4.
Am J Physiol Heart Circ Physiol ; 320(1): H381-H392, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33164576

ABSTRACT

Adequate adaptation of ventricular repolarization (VR) duration to changes in heart rate (HR) is important for cardiac electromechanical function and electrical stability. We studied the QT and QTpeak adaptation in response to abrupt start and stop of atrial and ventricular pacing on two occasions with an interval of at least 1 mo in 25 study subjects with permanent pacemakers. Frank vectorcardiography was used for data collection. Atrial or ventricular pacing was performed for 8 min aiming at a cycle length (CL) of 500 ms. We measured the immediate response (IR), the time constant (τ) of the exponential phase, and T90 End, the time to reach 90% change of QT and QTpeak from baseline to steady state during and after pacing. During atrial pacing, the CL decreased on average 45% from mean (SD) 944 (120) to 518 (46) ms and QT decreased on average 18% from 388 (20) to 318 (17) ms. For QT, T90 End was 103 (24) s and 126 (15) s after start versus stop of atrial pacing; a difference of 24 (27) s (P = 0.006). The response pattern was similar for τ but IR did not differ significantly between pacing start and stop. The response pattern was similar for QTpeak and also for QT and QTpeak following ventricular pacing start and stop. The coefficients of variation for repeated measures were 7%-21% for T90 End and τ. In conclusion, the adaptation of VR duration was significantly more rapid following increasing than decreasing HR and intraindividually a relatively reproducible process.NEW & NOTEWORTHY We studied the duration of ventricular repolarization (VR) adaptation and its hysteresis, following increasing and decreasing heart rate by abrupt start and stop of 8-min atrial or ventricular pacing in study subjects with permanent pacemakers and repeated the protocol with ≥1 mo interval, a novel approach. VR adaptation was significantly longer following decreasing than increasing heart rate corroborating previous observations. Furthermore, VR adaptation was intraindividually a reproducible and, hence, robust phenomenon, a novel finding.


Subject(s)
Action Potentials , Cardiac Pacing, Artificial , Heart Rate , Heart Ventricles/physiopathology , Pacemaker, Artificial , Sick Sinus Syndrome/therapy , Adaptation, Physiological , Aged , Female , Humans , Male , Middle Aged , Registries , Sick Sinus Syndrome/diagnosis , Sick Sinus Syndrome/physiopathology , Time Factors , Vectorcardiography
5.
Ann Noninvasive Electrocardiol ; 25(3): e12713, 2020 05.
Article in English | MEDLINE | ID: mdl-31707762

ABSTRACT

BACKGROUND: The duration of ventricular repolarization (VR) and its spatial and temporal heterogeneity are central elements in arrhythmogenesis. We studied the adaptation of VR duration and dispersion and their relationship in healthy human subjects during atrial pacing. METHODS: Patients 20-50 years of age who were scheduled for ablation of supraventricular tachycardia without preexcitation but otherwise healthy were eligible. Vectorcardiography recordings with Frank leads were used for data collection. Incremental atrial pacing from a coronary sinus electrode was performed by decrements of 10ms/cycle from just above sinus rate, and then kept at a fixed heart rate (HR) just below the Wenckebach rate for ≥5min and then stopped. VR duration was measured as QT and VR dispersion as T area, T amplitude and ventricular gradient. The primary measure (T90 End) was the time to reach 90% change from baseline to the steady state value during and after pacing. RESULTS: A complete study protocol was accomplished in 9 individuals (6 women). VR duration displayed a monophasic adaptation during HR acceleration lasting on average 20s. The median (Q1-Q3) T90 End for QT was 85s (51-104), a delay by a factor >4. All dispersion measures displayed a tri-phasic response pattern during HR acceleration and T90 End was 3-5 times shorter than for VR duration. CONCLUSIONS: Even during close to "physiological" conditions, complex and differing response patterns in VR duration and dispersion measures followed changes in HR. Extended knowledge about these responses in disease conditions might assist in risk evaluation and finding therapeutic alternatives.


Subject(s)
Atrial Function/physiology , Heart Rate/physiology , Tachycardia, Supraventricular/physiopathology , Ventricular Function/physiology , Adult , Cardiac Pacing, Artificial/methods , Female , Humans , Male , Middle Aged , Time Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...