1.
Spine (Phila Pa 1976) ; 32(2): 207-16, 2007 Jan 15.
Article in English | MEDLINE | ID: mdl-17224816

ABSTRACT

STUDY DESIGN: Retrospective cohort study with prospective clinical follow-up. OBJECTIVE: To determine the factors that influence outcome after surgery for cauda equina syndrome (CES). SUMMARY OF BACKGROUND DATA: CES is a rare but serious consequence of lumbar disc prolapse and can have devastating long-lasting neurologic consequences. The timing of surgical decompression remains controversial. METHODS: Fifty-six patients with evidence of a sphincteric disturbance who underwent urgent surgery were identified and invited to follow-up. The outcome measures comprised history and examination and several validated self-assessment questionnaires. RESULTS: Forty-two patients (78%) attended with a mean follow-up of 60 months (range, 25-114 months). Mean age at onset was 41 years (range, 24-67 years) with 23 males and 19 females. Twenty-six patients were operated on within 48 hours of onset of sphincteric symptoms; 5 of these were within 24 hours. Acute onset of sphincteric symptoms and the time to operation did not influence the outcomes. Leg weakness at onset persisted in a significant number of patients at follow-up (P < 0.005). Urinary disturbance at presentation did not affect the outcomes. At follow-up, significantly more females had urinary incontinence (P < 0.005). Bowel dysfunction at presentation was associated with sexual problems at follow-up (P < 0.005). The 13 patients who failed their post operative trial without catheter had worse outcomes. The SF-36 scores at follow-up were reduced compared with age-matched controls in the population. The mean ODI was 29, Low Back Outcome Score 42, and VAS 4.5. The time elapsed from operation to follow-up was not found to influence the outcomes. CONCLUSIONS: In our series, the symptom duration before operation and the speed of onset do not affect the outcome more than 2 years after surgery. Based on the SF-36, ODI, and Low Back Outcome Scores, patients who have had CES do not return to a normal status.


Subject(s)
Anal Canal/physiopathology , Polyradiculopathy/physiopathology , Polyradiculopathy/surgery , Adult , Aged , Cohort Studies , Fecal Incontinence/etiology , Female , Follow-Up Studies , Humans , Intervertebral Disc Displacement/complications , Intestinal Diseases/etiology , Leg , Low Back Pain/complications , Lumbar Vertebrae , Male , Middle Aged , Muscle Weakness/etiology , Orthopedic Procedures/adverse effects , Polyradiculopathy/complications , Polyradiculopathy/etiology , Prospective Studies , Recovery of Function , Retrospective Studies , Sacrum , Sciatica/complications , Sensation Disorders/etiology , Sexual Behavior , Time Factors , Urination Disorders/etiology
2.
Eur Spine J ; 15(12): 1853-7, 2006 Dec.
Article in English | MEDLINE | ID: mdl-16804675

ABSTRACT

This is a case report and laboratory-based biomechanics study. The objective is to report the first case of Titanium rod embolisation during scoliosis surgery into the Pulmonary artery. To investigate the potential of an unconstrained cut Titanium rod fragment to cause wounding with reference to recognised weapons. Embolisation of a foreign body to the heart is rare. Bullet embolisation to the heart and lungs is infrequently reported in the last 80 years. Iatrogenic cases of foreign body embolisation are very rare. Fifty 1-2 cm segments of Titanium rod were cut in an unconstrained manner and a novel method was used to calculate velocity. A high-speed camera (6,000 frames/s) was used to further measure velocity and study projectile motion. The wounding potential was investigated using lambs liver, high-speed photography and local dissection. Rod velocities were measured in excess of 23 m s(-1). Rods were seen to tumble end-over-end with a maximum speed of 560 revolutions/s. The maximum kinetic energy was 0.61 J which is approximately 2% that of a crossbow. This is sufficient to cause significant liver damage. The degree of surface damage and internal disruption was influenced by the orientation of the rod fragment at impact. An unconstrained cut segment of a Titanium rod has a significant potential to wound. Precautions should be taken to avoid this potentially disastrous but preventable complication.


Subject(s)
Bone Nails/adverse effects , Foreign-Body Migration/etiology , Intraoperative Complications/etiology , Pulmonary Embolism/etiology , Scoliosis/surgery , Adult , Animals , Biomechanical Phenomena , Female , Foreign-Body Migration/physiopathology , Humans , Intraoperative Complications/physiopathology , Liver/injuries , Models, Theoretical , Photography/methods , Pulmonary Artery , Pulmonary Embolism/physiopathology , Sheep , Spinal Fusion/instrumentation , Titanium , Wounds and Injuries/etiology , Wounds and Injuries/physiopathology