Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Tuberc Lung Dis ; 26(7): 658-663, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35768925

ABSTRACT

BACKGROUND: The WHO recommends the use of bedaquiline (BDQ) in longer, as well as shorter, multidrug-resistant TB (MDR-TB) treatment regimens. However, resistance to this new drug is now emerging. We aimed to describe the characteristics of patients in Karakalpakstan, Uzbekistan, who were treated for MDR-TB and acquired BDQ resistance during treatment.METHODS: We performed a retrospective study of routinely collected data for patients treated for MDR-TB in Karakalpakstan between January 2015 and December 2020. We included patients on BDQ-containing regimens with baseline susceptibility to BDQ who developed BDQ resistance at any point after treatment initiation. Patients resistant to BDQ at baseline or with no confirmed susceptibility to BDQ at baseline were excluded.RESULTS: Of the 523 patients who received BDQ-containing regimens during the study period, BDQ resistance was detected in 31 patients (5.9%); 20 patients were excluded-16 with no prior confirmation of BDQ susceptibility and 4 who were resistant at baseline. Eleven patients with acquired BDQ resistance were identified. We discuss demographic variables, resistance profiles, treatment-related variables and risk factors for unfavourable outcomes for these patients.CONCLUSION: Our programmatic data demonstrated the acquisition of BDQ resistance during or subsequent to receiving a BDQ-containing regimen in a patient cohort from Uzbekistan. We highlight the need for individualised treatment regimens with optimised clinical and laboratory follow up to prevent resistance acquisition.


Subject(s)
Antitubercular Agents , Tuberculosis, Multidrug-Resistant , Antitubercular Agents/adverse effects , Diarylquinolines/therapeutic use , Humans , Retrospective Studies , Tuberculosis, Multidrug-Resistant/drug therapy , Tuberculosis, Multidrug-Resistant/epidemiology , Uzbekistan/epidemiology
2.
Radiat Prot Dosimetry ; 170(1-4): 336-41, 2016 Sep.
Article in English | MEDLINE | ID: mdl-26541188

ABSTRACT

The formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Centre, Essen (Germany). The ambient dose equivalent H(*)(10) was assessed with Berthold LB 6411, WENDI-2, tissue-equivalent proportional counter (TEPC) and Bonner spheres (BS). The personal dose equivalent Hp(10) was measured with two types of active detectors and with bubble detectors. Using spectral and basic angular information, the reference Hp(10) was estimated. Results concerning staff exposure show H(*)(10) doses between 0.5 and 1 nSv/monitoring unit in a technical room. The LB 6411 showed an underestimation of H(*)(10), while WENDI-2 and TEPC showed good agreement with the BS data. A large overestimation for Hp(10) was observed for the active personal dosemeters, while the bubble detectors showed only a slight overestimation.


Subject(s)
Neutrons , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Proton Therapy/instrumentation , Radiation Protection/instrumentation , Radiometry/instrumentation , Algorithms , Germany , Humans , Monte Carlo Method , Phantoms, Imaging , Proton Therapy/methods , Radiation Dosage , Radiation Monitoring , Radiation Protection/methods , Radiometry/methods
3.
Radiat Prot Dosimetry ; 168(2): 149-53, 2016 Feb.
Article in English | MEDLINE | ID: mdl-25948828

ABSTRACT

The use of conventional Bonner Sphere Spectrometers (BSS) in pulsed neutron fields (PNF) is limited by the fact that proportional counters, usually employed as the thermal neutron detectors, suffer from dead time losses and show severe underestimation of the neutron interaction rate, which leads to strong distortion of the calculated spectrum. In order to avoid these limitations, an innovative BSS, called BSS-LUPIN, has been developed for measuring in PNF. This paper describes the physical characteristics of the device and its working principle, together with the results of Monte Carlo simulations of its response matrix. The BSS-LUPIN has been tested in the stray neutron field at the CERN Proton Synchrotron, by comparing the spectra obtained with the new device, the conventional CERN BSS and via Monte Carlo simulations.


Subject(s)
Computer Simulation , Neutrons , Radiation Monitoring/methods , Synchrotrons/instrumentation , Humans , Monte Carlo Method , Radiation Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...