Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Malar J ; 23(1): 111, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38641838

ABSTRACT

BACKGROUND: Sporozoites (SPZ), the infective form of Plasmodium falciparum malaria, can be inoculated into the human host skin by Anopheline mosquitoes. These SPZ migrate at approximately 1 µm/s to find a blood vessel and travel to the liver where they infect hepatocytes and multiply. In the skin they are still low in number (50-100 SPZ) and vulnerable to immune attack by antibodies and skin macrophages. This is why whole SPZ and SPZ proteins are used as the basis for most malaria vaccines currently deployed and undergoing late clinical testing. Mosquitoes typically inoculate SPZ into a human host between 14 and 25 days after their previous infective blood meal. However, it is unknown whether residing time within the mosquito affects SPZ condition, infectivity or immunogenicity. This study aimed to unravel how the age of P. falciparum SPZ in salivary glands (14, 17, or 20 days post blood meal) affects their infectivity and the ensuing immune responses. METHODS: SPZ numbers, viability by live/dead staining, motility using dedicated sporozoite motility orienting and organizing tool software (SMOOT), and infectivity of HC-04.j7 liver cells at 14, 17 and 20 days after mosquito feeding have been investigated. In vitro co-culture assays with SPZ stimulated monocyte-derived macrophages (MoMɸ) and CD8+ T-cells, analysed by flow cytometry, were used to investigate immune responses. RESULTS: SPZ age did not result in different SPZ numbers or viability. However, a markedly different motility pattern, whereby motility decreased from 89% at day 14 to 80% at day 17 and 71% at day 20 was observed (p ≤ 0.0001). Similarly, infectivity of day 20 SPZ dropped to ~ 50% compared with day 14 SPZ (p = 0.004). MoMɸ were better able to take up day 14 SPZ than day 20 SPZ (from 7.6% to 4.1%, p = 0.03) and displayed an increased expression of pro-inflammatory CD80, IL-6 (p = 0.005), regulatory markers PDL1 (p = 0.02), IL-10 (p = 0.009) and cytokines upon phagocytosis of younger SPZ. Interestingly, co-culture of these cells with CD8+ T-cells revealed a decreased expression of activation marker CD137 and cytokine IFNγ compared to their day 20 counterparts. These findings suggest that older (day 17-20) P. falciparum SPZ are less infectious and have decreased immune regulatory potential. CONCLUSION: Overall, this data is a first step in enhancing the understanding of how mosquito residing time affects P. falciparum SPZ and could impact the understanding of the P. falciparum infectious reservoir and the potency of whole SPZ vaccines.


Subject(s)
Culicidae , Malaria Vaccines , Malaria, Falciparum , Animals , Humans , Sporozoites , CD8-Positive T-Lymphocytes , Aging , Plasmodium falciparum
2.
J Nucl Med ; 65(4): 548-554, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38485277

ABSTRACT

Prostate-specific membrane antigen (PSMA) PET is used to select patients with recurrent prostate cancer for metastasis-directed therapy. A surgical approach can be achieved through radioguided surgery (RGS), using a Drop-In γ-probe that traces lesions that accumulate the radioactive signal. With the aim of guiding patient selection for salvage surgery, we studied the correlation between the SUVmax of lesions on preoperative PSMA PET/CT and their intraoperative counts/s measured using the Drop-In γ-probe. Methods: A secondary analysis based on the prospective, single-arm, and single-center feasibility study was conducted (NCT03857113). Patients (n = 29) with biochemical recurrence after previous curative-intent therapy and a maximum of 3 suggestive lesions within the pelvis on preoperative PSMA PET/CT were included. Patients treated with androgen deprivation therapy within 6 mo before surgery were excluded. All patients received an intravenous injection of 99mTc-PSMA-I&S 1 d before surgery. Radioguidance was achieved using a Drop-In γ-probe. Correlation was determined using the Spearman rank correlation coefficient (ρs). Subgroup analysis was based on the median SUVmax Results: In total, 33 lesions were visible on the PSMA PET/CT images, with a median overall SUVmax of 6.2 (interquartile range [IQR], 4.2-9.7). RGS facilitated removal of 31 lesions. The median Drop-In counts/s were 134 (IQR, 81-220) in vivo and 109 (IQR, 72-219) ex vivo. The intensity of the values correlated with SUVmax (ρs = 0.728 and 0.763, respectively; P < 0.001). Subgroup analysis based on median SUVmax in the group with an SUVmax of less than 6 showed no statistically significant correlation with the numeric signal in vivo (ρs = 0.382; P = 0.221) or the signal-to-background-ratio (ρs = 0.245; P = 0.442), whereas the group with an SUVmax of 6 or more showed respective statistically significant positive correlations (ρs = 0.774 [P < 0.001] and ρs = 0.647 [P = 0.007]). Conclusion: Our findings indicate that there is a direct relation between SUVmax on PSMA PET/CT and the readout recorded by the surgical Drop-In probe, thereby indicating that SUVmax can be used to select patients for PSMA RGS. For more definitive subgroup definitions for treatment recommendations, further studies are necessary to validate the present findings.


Subject(s)
Prostatic Neoplasms , Male , Humans , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Positron Emission Tomography Computed Tomography/methods , Androgen Antagonists , Prospective Studies , Neoplasm Recurrence, Local/pathology , Gallium Radioisotopes
4.
Biomolecules ; 13(6)2023 06 05.
Article in English | MEDLINE | ID: mdl-37371522

ABSTRACT

BACKGROUND: The occurrence of accidental nerve damage during surgery and the increasing application of image guidance during head-and-neck surgery have highlighted the need for molecular targeted nerve-sparing interventions. The implementation of such interventions relies on the availability of nerve-specific tracers. In this paper, we describe the development of a truncated peptide that has an optimized affinity for protein zero (P0), the most abundant protein in myelin. METHODS AND MATERIALS: Further C- and N-terminal truncation was performed on the lead peptide Cy5-P0101-125. The resulting nine Cy5-labelled peptides were characterized based on their photophysical properties, P0 affinity, and in vitro staining. These characterizations were combined with evaluation of the crystal structure of P0, which resulted in the selection of the optimized tracer Cy5-P0112-125. A near-infrared Cy7-functionalized derivative (Cy7-P0112-125) was used to perform an initial evaluation of fluorescence-guided surgery in a porcine model. RESULTS: Methodological truncation of the 26-amino-acid lead compound Cy5-P0101-125 resulted in a size reduction of 53.8% for the optimized peptide Cy5-P0112-125. The peptide design and the 1.5-fold affinity gain obtained after truncation could be linked to interactions observed in the crystal structure of the extracellular portion of P0. The near-infrared analogue Cy7-P0112-125 supported nerve illumination during fluorescence-guided surgery in the head-and-neck region in a porcine model. CONCLUSIONS: Methodological truncation yielded a second-generation P0-specific peptide. Initial surgical evaluation suggests that the peptide can support molecular targeted nerve imaging.


Subject(s)
Amino Acids , Myelin P0 Protein , Animals , Swine , Myelin P0 Protein/analysis , Myelin P0 Protein/chemistry , Myelin P0 Protein/metabolism , Amino Acids/analysis , Fluorescence , Peptides/analysis , Myelin Sheath/metabolism
5.
Eur J Nucl Med Mol Imaging ; 50(8): 2282-2291, 2023 07.
Article in English | MEDLINE | ID: mdl-36929210

ABSTRACT

BACKGROUND: Lymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-99mTc-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-99mTc-nanoscan compared to ICG-99mTc-nanocolloid from a nuclear and surgical perspective. METHODS: Twenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-99mTc-nanocolloid until no longer available; the second group (n = 13) received ICG-99mTc-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors. RESULTS: The mean tracer uptake in the SNs was similar for ICG-99mTc-nanocolloid (2.2 ± 4.3%ID) and ICG-99mTc-nanoscan (1.8 ± 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-99mTc-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-99mTc-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-99mTc-nanoscan group (24*109 arbitrary units (A.U) IQR 1.6*109-14*109 in the ICG-99mTc-nanocolloid group versus 4.6*109 A.U. IQR 2.4*109-42*109 in the ICG-99mTc-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported. CONCLUSIONS: Based on this retrospective analysis, we can conclude that ICG-99mTc-nanoscan has similar capacity for SN identification as ICG-99mTc-nanocolloid and can safely be implemented in SN procedures.


Subject(s)
Melanoma , Nuclear Medicine , Penile Neoplasms , Sentinel Lymph Node , Male , Humans , Indocyanine Green , Sentinel Lymph Node Biopsy/methods , Retrospective Studies , Sentinel Lymph Node/surgery , Melanoma/diagnostic imaging , Melanoma/surgery , Melanoma/pathology , Radiopharmaceuticals , Lymphatic Metastasis , Penile Neoplasms/pathology , Technetium Tc 99m Aggregated Albumin
6.
Mol Imaging Biol ; 25(1): 180-189, 2023 02.
Article in English | MEDLINE | ID: mdl-35711014

ABSTRACT

PURPOSE: Surgical fluorescence guidance has gained popularity in various settings, e.g., minimally invasive robot-assisted laparoscopic surgery. In pursuit of novel receptor-targeted tracers, the field of fluorescence-guided surgery is currently moving toward increasingly lower signal intensities. This highlights the importance of understanding the impact of low fluorescence intensities on clinical decision making. This study uses kinematics to investigate the impact of signal-to-background ratios (SBR) on surgical performance. METHODS: Using a custom grid exercise containing hidden fluorescent targets, a da Vinci Xi robot with Firefly fluorescence endoscope and ProGrasp and Maryland forceps instruments, we studied how the participants' (N = 16) actions were influenced by the fluorescent SBR. To monitor the surgeon's actions, the surgical instrument tip was tracked using a custom video-based tracking framework. The digitized instrument tracks were then subjected to multi-parametric kinematic analysis, allowing for the isolation of various metrics (e.g., velocity, jerkiness, tortuosity). These were incorporated in scores for dexterity (Dx), decision making (DM), overall performance (PS) and proficiency. All were related to the SBR values. RESULTS: Multi-parametric analysis showed that task completion time, time spent in fluorescence-imaging mode and total pathlength are metrics that are directly related to the SBR. Below SBR 1.5, these values substantially increased, and handling errors became more frequent. The difference in Dx and DM between the targets that gave SBR < 1.50 and SBR > 1.50, indicates that the latter group generally yields a 2.5-fold higher Dx value and a threefold higher DM value. As these values provide the basis for the PS score, proficiency could only be achieved at SBR > 1.55. CONCLUSION: By tracking the surgical instruments we were able to, for the first time, quantitatively and objectively assess how the instrument positioning is impacted by fluorescent SBR. Our findings suggest that in ideal situations a minimum SBR of 1.5 is required to discriminate fluorescent lesions, a substantially lower value than the SBR 2 often reported in literature.


Subject(s)
Coloring Agents , Surgery, Computer-Assisted , Humans
7.
Int J Comput Assist Radiol Surg ; 17(10): 1775-1785, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35934773

ABSTRACT

PURPOSE: Navigational strategies create a scenario whereby percutaneous needle-based interventions of the liver can be guided using both pre-interventional 3D imaging datasets and dynamic interventional ultrasound (US). To score how such technologies impact the needle placement process, we performed kinematic analysis on different user groups. METHODS: Using a custom biopsy phantom, three consecutive exercises were performed by both novices and experts (n = 26). The exercise came in three options: (1) US-guidance, (2) US-guidance with pre-interventional image-registration (US + Reg) and (3) US-guidance with pre-interventional image-registration and needle-navigation (US + Reg + Nav). The traveled paths of the needle were digitized in 3D. Using custom software algorithms, kinematic metrics were extracted and related to dexterity, decision making indices to obtain overall performance scores (PS). RESULTS: Kinematic analysis helped quantifying the visual assessment of the needle trajectories. Compared to US-guidance, novices yielded most improvements using Reg (PSavg(US) = 0.43 vs. PSavg(US+Reg) = 0.57 vs. PSavg(US+Reg+Nav) = 0.51). Interestingly, the expert group yielded a reversed trend (PSavg(US) = 0.71 vs PSavg(US+Reg) = 0.58 vs PSavg(US+Reg+Nav) = 0.59). CONCLUSION: Digitizing the movement trajectory allowed us to objectively assess the impact of needle-navigation strategies on percutaneous procedures. In particular, our findings suggest that these advanced technologies have a positive impact on the kinematics derived performance of novices.


Subject(s)
Needles , Surgery, Computer-Assisted , Computers , Humans , Phantoms, Imaging , Surgery, Computer-Assisted/methods , Ultrasonography , Ultrasonography, Interventional/methods
8.
Int J Comput Assist Radiol Surg ; 17(1): 211-218, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34333740

ABSTRACT

PURPOSE: Sentinel lymph node biopsy is a routine procedure for nodal staging in penile cancer. Most commonly, this procedure is guided by radioactive tracers, providing various forms of preoperative and intraoperative guidance. This is further extended with fluorescence imaging using hybrid radioactive-fluorescence tracers. Alternatively, a magnetic-based approach has become available using superparamagnetic iron-oxide nanoparticles (SPIONs). This study investigates a novel freehand magnetic particle imaging and navigation modality (fhMPI) for intraoperative localization, along with a hybrid approach, combining magnetic and fluorescence guidance. MATERIALS AND METHODS: The fhMPI set-up was built with a surgical navigation device, optical tracking system and magnetometer probe. A dedicated reconstruction software based on a look-up-table method was used to reconstruct a superficial 3D volume of the SPION distribution in tissue. For fluorescence guidance, indocyanine green (ICG) was added to the SPIONs. The fhMPI modality was characterized in phantoms, ex vivo human skin and in vivo porcine surgery. RESULTS: Phantom and human skin explants illustrated that the current fhMPI modality had a sensitivity of 2.2 × 10-2 mg/mL SPIONs, a resolving power of at least 7 mm and a depth penetration up to 1.5 cm. Evaluation during porcine surgery showed that fhMPI allowed for an augmented reality image overlay of the tracer distribution in tissue, as well as 3D virtual navigation. Besides, using the hybrid approach, fluorescence imaging provided a visual confirmation of localized nodes. CONCLUSION: fhMPI is feasible in vivo, providing 3D imaging and navigation for magnetic nanoparticles in the operating room, expanding the guidance possibilities during magnetic sentinel lymph node procedures. Furthermore, the integration of ICG provides the ability to visually refine and confirm correct localization. Further clinical evaluation should verify these findings in human patients as well.


Subject(s)
Imaging, Three-Dimensional , Surgery, Computer-Assisted , Animals , Humans , Indocyanine Green , Optical Imaging , Sentinel Lymph Node Biopsy , Swine
9.
Q J Nucl Med Mol Imaging ; 65(3): 244-260, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34105338

ABSTRACT

INTRODUCTION: Nuclear medicine has a crucial role in interventional strategies where a combination between the increasing use of targeted radiotracers and intraprocedural detection modalities enable novel, but often complex, targeted procedures in both the fields of interventional radiology and surgery. 3D navigation approaches could assist the interventional radiologist or surgeon in such complex procedures. EVIDENCE ACQUISITION: This review aimed to provide a comprehensive overview of the current application of computer-assisted navigation strategies based on nuclear imaging to assist in interventional radiology and image-guided surgery. This work starts with a brief overview of the typical navigation workflow from a technical perspective, which is followed by the different clinical applications organized based on their anatomical organ of interest. EVIDENCE SYNTHESIS: Although many studies have proven the feasibility of PET- and SPECT-based navigation strategies for various clinical applications in both interventional radiology and surgery, the strategies are spread widely in both navigation workflows and clinical indications, evaluated in small patient groups. Hence, no golden standard has yet been established. CONCLUSIONS: Despite that the clinical outcome is yet to be determined in large patient cohorts, navigation seems to be a promising technology to translate nuclear medicine findings, provided by PET- and SPECT-based molecular imaging, to the intervention and operating room. Interventional Nuclear Medicine (iNM) has an exciting future to come using both PET- and SPECT-based navigation.


Subject(s)
Nuclear Medicine , Surgery, Computer-Assisted , Humans , Positron-Emission Tomography , Radiology, Interventional , Tomography, Emission-Computed, Single-Photon
10.
Eur J Nucl Med Mol Imaging ; 48(13): 4142-4151, 2021 12.
Article in English | MEDLINE | ID: mdl-34031721

ABSTRACT

PURPOSE: Decision-making and dexterity, features that become increasingly relevant in (robot-assisted) minimally invasive surgery, are considered key components in improving the surgical accuracy. Recently, DROP-IN gamma probes were introduced to facilitate radioguided robotic surgery. We now studied if robotic DROP-IN radioguidance can be further improved using tethered Click-On designs that integrate gamma detection onto the robotic instruments themselves. METHODS: Using computer-assisted drawing software, 3D printing and precision machining, we created a Click-On probe containing two press-fit connections and an additional grasping moiety for a ProGrasp instrument combined with fiducials that could be video tracked using the Firefly laparoscope. Using a dexterity phantom, the duration of the specific tasks and the path traveled could be compared between use of the Click-On or DROP-IN probe. To study the impact on surgical decision-making, we performed a blinded study, in porcine models, wherein surgeons had to identify a hidden 57Co-source using either palpation or Click-On radioguidance. RESULTS: When assembled onto a ProGrasp instrument, while preserving grasping function and rotational freedom, the fully functional prototype could be inserted through a 12-mm trocar. In dexterity assessments, the Click-On provided a 40% reduction in movements compared to the DROP-IN, which converted into a reduction in time, path length, and increase in straightness index. Radioguidance also improved decision-making; task-completion rate increased by 60%, procedural time was reduced, and movements became more focused. CONCLUSION: The Click-On gamma probe provides a step toward full integration of radioguidance in minimal invasive surgery. The value of this concept was underlined by its impact on surgical dexterity and decision-making.


Subject(s)
Robotic Surgical Procedures , Robotics , Animals , Minimally Invasive Surgical Procedures , Swine
11.
J Nucl Med ; 62(9): 1314-1317, 2021 09 01.
Article in English | MEDLINE | ID: mdl-33419942

ABSTRACT

With translation of the Drop-In γ-probe, radioguidance has advanced into laparoscopic robot-assisted surgery. Global-positioning-system-like navigation can further enhance the symbiosis between nuclear medicine and surgery. Therefore, we developed a fluorescence-video-based tracking method that integrates the Drop-In with navigated robotic surgery. Methods: Fluorescent markers, integrated into the Drop-In, were automatically detected using a daVinci Firefly laparoscope. Subsequently, a declipseSPECT-navigation platform calculated the Drop-In location within the surgical field. Using a phantom (n = 3), we pursued robotic navigation on SPECT/CT, whereas intraoperative feasibility was validated during porcine surgery (n = 4). Results: Video-based tracking allowed for navigation of the Drop-In toward all lesions detected on SPECT/CT (external iliac and common iliac artery regions). Augmented-reality visualization in the surgical console indicated the distance to these lesions in real time, confirmed by the Drop-In readout. Porcine surgery underlined the feasibility of the concept. Conclusion: Optical navigation of the Drop-In probe provides a next step toward connecting nuclear medicine with robotic surgery.


Subject(s)
Robotic Surgical Procedures , Laparoscopy , Surgery, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...