Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Clin Anat ; 31(5): 693-697, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29700864

ABSTRACT

Bicuspid aortic valves are associated with histopathological abnormalities of the aorta. Their diameters have been measured in several studies, but the literature concerning changes in the overall anatomy of the ascending aorta is limited. We wanted to know whether the anatomy of the valve, bicuspid or tricuspid, is associated with anatomical differences. We prospectively included patients requiring aortic valve surgery. The protocol included a chest CT scan before the operation to determine the angulations and straight lengths of aortic segments 0 and 1. All of the patients underwent surgery to assess their aortic valve morphology. We included 107 patients, 25 (23%) with bicuspid diagnostic valves and 82 (77%) with tricuspid ones. Most angulations were similar between the groups. However, the angle between the ring and the plane of the top of the commissures of the semilunar cusps was lower in bicuspid than tricuspid aortic valves. The straight lengths in the aortic root did not differ significantly, but the lengths separating these planes from the BCAT plane were consistently greater in the bicuspid group. The angle between the ring plane and the patient's vertical axis was lower in the bicuspid, the plane of the ring being verticalized in this group. In conclusion, we were able to confirm significant morphological differences in addition to the diameters. However, this study does not establish causal relationships among valve morphology, ascending aortic morphology, histology, and possibly associated pathologies. An extremely large cohort will be required indicate such causal connections. Clin. Anat. 31:693-697, 2018. © 2018 Wiley Periodicals, Inc.


Subject(s)
Aorta/pathology , Aortic Valve/abnormalities , Heart Valve Diseases/pathology , Aged , Aged, 80 and over , Aorta/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Bicuspid Aortic Valve Disease , Female , Heart Valve Diseases/diagnostic imaging , Humans , Male , Prospective Studies
2.
Surg Radiol Anat ; 39(7): 703-710, 2017 Jul.
Article in English | MEDLINE | ID: mdl-27921138

ABSTRACT

BACKGROUND: Only a few studies, involving small numbers of patients, have globally assessed the curvature of the thoracic aorta but without any details concerning the location of the supra-aortic trunks. OBJECTIVES: Using CT to describe normal aortic-arch morphology and its changes with age and sex. METHODS: 344 CT scans were studied. We measured the distances from the apex to the ascending and descending aorta, the curvilinear length of the entire arch, that of the segment, including bifurcations of supra-aortic vessels, and the angle, height, and shift of the arch. RESULTS: In men, the arch was significantly longer (146.2 vs 122.8 mm; p < 0.001), higher (49.3 vs 40.1 mm, p < 0.001), and wider transversely (83.6 vs 73.3 mm; p < 0.001) than in women. The average men's arch also had a more acute angle at the apex (79.7° vs 83.7° p < 0.001). Neither morphology nor age influenced the winding angle around the mediastinum. Aging was accompanied by deflection and extension of the aortic arch, which grew more anteroposteriorly (6.1 mm/10 years in men) than vertically (2.5 mm/10 years in men), while the apex moved towards the rear of the arch. The ascending aorta was the only curvilinear length unaffected by age, whereas the supra-aortic trunks parted from each other. CONCLUSION: We believe that all these original observations could lead to a better assessment of normal aging of the aorta and guide technical choices during surgical or hybrid procedures.


Subject(s)
Aging/pathology , Aorta, Thoracic/anatomy & histology , Adolescent , Adult , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Female , Humans , Male , Middle Aged , Radiography, Thoracic , Tomography, X-Ray Computed , Young Adult
3.
Ann Cardiol Angeiol (Paris) ; 65(1): 7-14, 2016 Feb.
Article in French | MEDLINE | ID: mdl-25641084

ABSTRACT

INTRODUCTION: Patients with a history of coronary artery bypass and aortic valve disease constitute a high-risk group for conventional redo surgery. The transcatheter aortic valve implantation (TAVI) may be an alternative for high-risk patients. The purpose of this study is to evaluate the impact of TAVI in the treatment of aortic valve disease after previous surgical coronary artery revascularization. PATIENTS AND METHODS: This is a single-center retrospective, observational study, including 87 patients undergoing surgery for surgical heart valve replacement or TAVI from January 2007 to December 2013. RESULTS: The introduction of transcatheter aortic valve implantation techniques has doubled the number of redo patients treated for aortic valve disease. From 2010 to 2013, the patients treated by conventional surgery diminished by 30%, with improved postoperative outcomes. This study allowed us to notice differences in patient's in terms of operative risk factors. For the same reasons no comparison was possible between 2 subgroup of patients. Hospital mortality was 6.4% for conventional aortic surgery and 20% for transcatheter aortic valve treatment. CONCLUSION: Surgery remains the standard treatment for aortic valve disease even in redo patients, but TAVI becomes a very interesting tool as it may represent a tailored approach for our patients.


Subject(s)
Coronary Artery Bypass , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/surgery , Female , France/epidemiology , Hospital Mortality , Humans , Male , Middle Aged , Retrospective Studies
4.
Ann Cardiol Angeiol (Paris) ; 61(5): 370-4, 2012 Nov.
Article in French | MEDLINE | ID: mdl-22959437

ABSTRACT

Pericardial mesothelioma is a rare form of pericardial tumor. The invasive investigations such as biopsy make the diagnosis. Non-invasive imaging techniques provide valuable information about its diagnosis and its clinical impact. We report here the results of magnetic resonance imaging of pericardial mesothelioma in a 65-year-old woman. The originality and purpose of this case is to illustrate the additional value of magnetic resonance imaging that should be systematically performed when assessing this pathology.


Subject(s)
Heart Neoplasms/diagnosis , Magnetic Resonance Imaging , Mesothelioma/diagnosis , Pericardium/pathology , Aged , Early Detection of Cancer , Female , Heart Neoplasms/pathology , Humans , Prognosis
5.
Case Rep Cardiol ; 2012: 704098, 2012.
Article in English | MEDLINE | ID: mdl-24826270

ABSTRACT

Papillary fibroelastomas are cardiac benign tumours. Among the benign cardiac tumor, papillary fibroelastomas are reported second after myxomas. Most often diagnosed incidentally, papillary fibroelastomas may embolize to cerebral circulation. Valvular locations are predominant; location in left atrium is rare. In this paper, we present a case of papillary fibroelastoma located in left atrium with symptoms of cerebral embolization. Transoesophageal echocardiography diagnosed a mobile mass. The patient was treated with surgical resection without further embolic complication.

6.
Ann Cardiol Angeiol (Paris) ; 60(5): 296-9, 2011 Nov.
Article in French | MEDLINE | ID: mdl-21978821

ABSTRACT

Pseudo-aneurysm of the fibrous continuity zone between the aortic and mitral valves, the so-called "mitral-aortic intervalvular fibrosa" is a rare complication of acute infective endocarditis, rarely after an aortic valve replacement. We report the case of a large pseudo-aneurysm occurred in a 70-year-old man, who had a history of surgical aortic valve replacement 3 years before. There were no biological or clinical evidence for infective acute endocarditis. The originality of this observation can be summarized in three points: the late onset after surgery, the absence of any infectious context and the chronic nature of pseudo-aneurysm, without any complication during a follow-up of 12 months. Transesophageal echocardiography remains the best diagnostic tool.


Subject(s)
Aneurysm, False/diagnostic imaging , Aneurysm, False/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/diagnostic imaging , Aged , Aneurysm, False/etiology , Follow-Up Studies , Humans , Male , Rare Diseases , Reoperation , Treatment Outcome
7.
Ann Fr Anesth Reanim ; 27(6): 510-3, 2008 Jun.
Article in French | MEDLINE | ID: mdl-18565723

ABSTRACT

We report the case of a 37-year-old woman who survived from severe hypothermia (rectal temperature: 22 degrees C) and prolonged cardiac arrest with asystole after benzodiazepine and tricyclic antidepressant poisoning. Basic-cardiopulmonary resuscitation and mechanical ventilation was started by a French Mobile Intensive-Care unit. Spontaneous circulation was restored at 25 degrees C under epinephrin after three hours of chest compression from home to the intensive-care unit and rewarming with extracorporeal circulation. The patient was discharged at day 13 without any neurological deficit. The discussion focuses on the benefit of extracorporeal-membrane oxygenation (ECMO) as extracorporeal circulation device through femoral access, the differential diagnosis between death and recoverable cardiac arrest and neuroprotection.


Subject(s)
Antidepressive Agents, Tricyclic/toxicity , Benzodiazepines/toxicity , Coma/chemically induced , Extracorporeal Membrane Oxygenation , Heart Arrest/chemically induced , Resuscitation , Adult , Female , Humans , Hypothermia/chemically induced , Treatment Outcome
8.
J Radiol ; 88(11 Pt 1): 1709-15, 2007 Nov.
Article in French | MEDLINE | ID: mdl-18065931

ABSTRACT

PURPOSE: To describe the imaging work-up and management of type III endoleaks detected after covered stent-graft treatment of descending thoracic aortic aneurysms. PATIENTS AND METHODS: Retrospective study of circumstances surrounding the diagnosis, management and outcome type III endoleaks occuring in 3 of 18 patients following covered stent-graft treatment of descending thoracic aortic aneurysms between April 1998 and July 2005. The endoleaks were detected at a mean follow-up of 22 months (19-24 months) after stent-graft placement. RESULTS: The type III endoleaks were detected on scheduled follow-up CT examinations in asymptomatic patients. Endovascular management was proposed at a mean interval time of 4.4 months (1 week - 11 months) after diagnosis of the endoleak, and was successful in all 3 cases. One patient died 1 month after endovascular repeai of the leak, 1 patient required surgical management at 14 months for new recurrence, and 1 patient had a favorable outcome at 2 months. CONCLUSION: Follow-up of patients after covered stent-graft treatment of descending thoracic aortic aneurysms is required. Prompt endovascular repair of delayed complications may be possible, but surgical management may become necessary.


Subject(s)
Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Prosthesis Failure , Stents , Angiography , Aortography , Blood Vessel Prosthesis Implantation/instrumentation , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications , Reoperation , Retrospective Studies , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
9.
J Hosp Infect ; 67(1): 62-6, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17719131

ABSTRACT

Surgical site infection after heart surgery increases morbidity and mortality. The method of presurgical hand disinfection could influence the infection risk. From February to April 2003, we compared the microbiological efficacy of hand-rubbing (R) and hand-scrubbing (S) procedures. The surgical team alternately used hand-scrubbing or hand-rubbing techniques every two weeks. Fingertip impressions were taken before and immediately after hand disinfection, every 2h and at the end of the operation. Acceptability of hand rubbing was assessed by a questionnaire. Mean durations of surgical procedures were 259+/-68 and 244+/-69min for groups S and R respectively (P=0.43). Bacterial counts immediately after hand disinfection were comparable with the two techniques, but significantly lower in group R at the end of surgery. No differences were observed between the percentages of negative samples taken after 2h, 4h and at the end of surgery between the two groups. Bacterial skin flora reduction immediately after hand disinfection, after 2h and 4h of operating time and at the end of surgery was better in group R, but the difference was not statistically significant. Before surgery, the hand-rubbing method with alcohol solution preceded by hand washing with mild neutral soap is as effective as hand scrubbing to reduce bacterial counts on hands. It decreased the bacterial counts both immediately after hand disinfection and at the end of long cardiothoracic surgical procedures. The acceptability of hand rubbing was excellent and it can be considered to be a valid alternative to the conventional hand-scrubbing protocol.


Subject(s)
Hand Disinfection/methods , Hand/microbiology , Infection Control/methods , Surgical Wound Infection/prevention & control , 1-Propanol/therapeutic use , Anti-Infective Agents, Local/therapeutic use , Chlorhexidine/therapeutic use , Colony Count, Microbial , France , Humans , Nurses , Physicians , Povidone-Iodine/therapeutic use , Prospective Studies , Soaps/therapeutic use , Surgical Wound Infection/epidemiology
10.
J Radiol ; 87(9): 1073-7, 2006 Sep.
Article in French | MEDLINE | ID: mdl-16936629

ABSTRACT

PURPOSE: To retrospectively assess the value of MRI in long-term follow-up of aortic dissection (AD) and its impact on therapy. MATERIALS AND METHODS: Comparison of clinical progression and analysis of 215 MRI examinations performed on 56 patients in our center from 1991 to 2002. RESULTS: Twenty-six patients (46%) had AD complications: 14 (54%) were asymptomatic and eight (31%) had subsequent surgical repair (native aorta upstream prosthesis disease in three patients and aneurismal dilatation of false lumen in five cases). Of the eight patients with secondary surgery, five (63%) were clinically asymptomatic. The delay between initial dissection and secondary surgery was less than 5 years in five patients and exceeded 10 years in three cases. The remaining 30 patients (54%) had unmodified radiological findings after a mean follow-up of 3.5 years (6 months to 9 years). CONCLUSION: MRI depicted AD complications in long-term follow-up of sometimes asymptomatic patients, allowing for adaptation of surgical treatment in 26 cases (46%).


Subject(s)
Aortic Aneurysm, Thoracic/diagnosis , Aortic Dissection/diagnosis , Magnetic Resonance Imaging , Adult , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL