Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 14(2)2023 Feb 04.
Article in English | MEDLINE | ID: mdl-36838094

ABSTRACT

Nanofiber membranes are starting to be used as an electrolyte storage medium because of their high porosity, which causes ionic conductivity, producing high energy. The ability of nanofiber membranes to absorb electrolytes proves their stability when used for a long time. In this study, the loading of acetylene carbon black (ACB) on polyacrylonitrile (PAN) is made by the electrospun method, which in turn is applied as an electrolyte medium in DSSC. Materials characterization was carried out through FTIR to determine the functional groups formed and SEM to observe morphology and diameter distribution. Furthermore, for DSSC performance, efficiency and EIS tests were carried out. The optimum nanofiber membrane was shown by esPACB1, with the highest efficiency reaching 1.92% with a porosity of 73.43%, nanofiber diameter of 172.9 ± 2.2 nm, an absorbance of 1850, and an electron lifetime of 0.003 ms.

2.
Sensors (Basel) ; 14(7): 12885-99, 2014 Jul 18.
Article in English | MEDLINE | ID: mdl-25046015

ABSTRACT

A new photonics biosensor configuration comprising a Double-side Ring Add-drop Filter microring resonator (DR-ADF) made from SiO2-TiO2 material is proposed for the detection of Salmonella bacteria (SB) in blood. The scattering matrix method using inductive calculation is used to determine the output signal's intensities in the blood with and without presence of Salmonella. The change in refractive index due to the reaction of Salmonella bacteria with its applied antibody on the flagellin layer loaded on the sensing and detecting microresonator causes the increase in through and dropper port's intensities of the output signal which leads to the detection of SB in blood. A shift in the output signal wavelength is observed with resolution of 0.01 nm. The change in intensity and shift in wavelength is analyzed with respect to the change in the refractive index which contributes toward achieving an ultra-high sensitivity of 95,500 nm/RIU which is almost two orders higher than that of reported from single ring sensors and the limit of detection is in the order of 1 × 10(-8) RIU. In applications, such a system can be employed for a high sensitive and fast detection of bacteria.


Subject(s)
Biosensing Techniques/methods , Blood/microbiology , Equipment Design/methods , Salmonella/chemistry , Equipment Failure Analysis/methods , Humans , Nanotechnology/methods , Optics and Photonics/methods , Refractometry/methods , Silicon Dioxide/chemistry , Titanium/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...