Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Expert Rev Med Devices ; 20(5): 373-391, 2023 May.
Article in English | MEDLINE | ID: mdl-37000987

ABSTRACT

INTRODUCTION: Carotid artery angioplasty and stenting (CAS) is an established procedure to treat carotid artery stenosis for either primary or secondary prevention of stroke. Randomized clinical trials have shown an increased risk of periprocedural cerebrovascular events with CAS compared with carotid endarterectomy (CEA). Several strategies have been proposed to mitigate this risk, including alternative vascular access site, proximal/distal embolic protection devices, and dual-layer stents, among others. AREAS COVERED: This review provides a general overview of current embolic protection strategies for CAS. The phases of the procedure which can affect the early risk of stroke and how to reduce it with novel techniques and devices have been discussed. EXPERT OPINION: Innovations in device technologies have dramatically improved the safety and efficacy of CAS. To minimize the gap with surgery, a thorough, patient-oriented approach should be pursued. Endovascular technologies and techniques should be selected on an individual basis to address unique lesion characteristics and vascular anatomies. Meticulous pre-procedural planning, both clinical and anatomical, is needed to assess the embolic risk of each procedure. Only by having an in-depth understanding of the wide range of available endovascular devices and techniques, the operator will choose the most appropriate strategy to optimize CAS results.


Subject(s)
Carotid Stenosis , Embolic Protection Devices , Stroke , Humans , Carotid Stenosis/surgery , Treatment Outcome , Stents/adverse effects , Stroke/prevention & control , Stroke/complications , Carotid Arteries/surgery , Risk Factors
2.
EuroIntervention ; 16(18): e1511-e1517, 2021 Apr 02.
Article in English | MEDLINE | ID: mdl-32091397

ABSTRACT

AIMS: Refractory angina is still a major public health problem. The coronary sinus Reducer (CSR) has recently been introduced as an alternative treatment to reduce symptoms in these patients. The aim of this study was to investigate objective improvements in effort tolerance and oxygen kinetics as assessed by cardiopulmonary exercise testing (CPET) in patients suffering from refractory angina undergoing CSR implantation. METHODS AND RESULTS: In this multicentre prospective study, patients with chronic refractory angina undergoing CSR implantation were scheduled for CPET before the index procedure and at six-month follow-up. The main endpoints of this analysis were improvements in VO2 max and in VO2 at the anaerobic threshold (AT). Clinical events and improvements in symptoms were also recorded. A total of 37 patients formed the study population. The CSR implantation procedure was successful and without complications in all. At follow-up CPET, significant improvement in VO2 max (+0.97 ml/kg/min [+11.3%]; 12.2±3.6 ml/kg/min at baseline vs 13.2±3.7 ml/kg/min, p=0.026), and workload (+12.9 [+34%]; 68±28 W vs 81±49 W, p=0.05) were observed, with non-significant differences in VO2 at the AT (9.84±3.4 ml/kg/min vs 10.74±3.05 ml/kg/min, p=0.06). Canadian Cardiovascular Society (CCS) grade improved from a mean of 3.2±0.5 to 1.6±0.8 (p<0.01), and significant benefits in all Seattle Angina Questionnaire variables were shown. CONCLUSIONS: In patients with obstructive coronary artery disease suffering from refractory angina, the implantation of a CSR was associated with objective improvement in exercise capacity and oxygen kinetics at CPET, suggesting a possible reduction of myocardial ischaemia.


Subject(s)
Coronary Sinus , Canada , Coronary Sinus/surgery , Humans , Kinetics , Oxygen , Prospective Studies , Treatment Outcome
5.
Catheter Cardiovasc Interv ; 93(3): 419-425, 2019 02 15.
Article in English | MEDLINE | ID: mdl-30280487

ABSTRACT

OBJECTIVES: In this retrospective observational study, we investigate outcome of patients treated with or without covered stent (CS) implantation in the management of coronary artery perforation (CAP) during coronary intervention. BACKGROUND: CSs have shown to be effective devices to achieve acute hemostasis in large CAP. However, doubts have been raised regarding their long-term outcome. METHODS: Data of 19 061 PCI procedures during a 10-year period were reviewed. Fifty-five cases of large CAP were withheld (Ellis type 2, 3 or cavity spilling). All medical and procedural records of these cases were retrospectively reviewed. RESULTS: Twenty-four (43.6%) patients were treated with CS implantation (15 polytetrafluoroethylene and 9 pericardium CSs). Twenty-six (47.3%) patients were managed without CS implantation, of whom five had unsuccessful delivery of a CS (stent delivery failure 17.2%). Although significantly more Ellis type-3 perforations were present in the CS group compared to the Non-CS group (75.0% vs 45.2%; P = 0.03), in-hospital mortality was not significantly different (8.3% vs 6.4%; [P = 0.79]). We observed a high rate of CS restenosis (29.2%) but a lower rate of CS thrombosis (4.2%). Despite these observations, 5-year MACE and all-cause mortality were not significantly different between CS and Non-CS group (respectively, 58.8% vs 50.0% (P = 0.26) and 26.7% vs 13.3% (P = 0.36)). CONCLUSION: Although deliverability of CSs was not flawless and a high rate of CS restenosis appeared, short- and long-term outcome were comparable between patients treated with or without CS. Therefore, CSs are justifiable in the treatment of CAP.


Subject(s)
Coated Materials, Biocompatible , Coronary Vessels/injuries , Heart Injuries/therapy , Hemostatic Techniques/instrumentation , Percutaneous Coronary Intervention/instrumentation , Stents , Aged , Aged, 80 and over , Coronary Restenosis/mortality , Coronary Vessels/diagnostic imaging , Female , Heart Injuries/diagnostic imaging , Heart Injuries/etiology , Heart Injuries/mortality , Hemostatic Techniques/adverse effects , Hemostatic Techniques/mortality , Hospital Mortality , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Pericardium/transplantation , Polytetrafluoroethylene , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
7.
J Am Heart Assoc ; 4(3): e001584, 2015 Mar 19.
Article in English | MEDLINE | ID: mdl-25792128

ABSTRACT

BACKGROUND: Our aim was to compare three-dimensional (3D) and 2D and 3D speckle-tracking (2D-STE, 3D-STE) echocardiographic parameters with conventional right ventricular (RV) indexes in patients with chronic pulmonary hypertension (PH), and investigate whether these techniques could result in better correlation with hemodynamic variables indicative of heart failure. METHODS AND RESULTS: Seventy-three adult patients (mean age, 53±13 years; 44% male) with chronic PH of different etiologies were studied by echocardiography and cardiac catheterization (25 precapillary PH from pulmonary arterial hypertension, 23 obstructive pulmonary heart disease, and 23 postcapillary PH from mitral regurgitation). Thirty healthy subjects (mean age, 54±15 years; 43% male) served as controls. Standard 2D measurements (RV-fractional area change-tricuspid annular plane systolic excursion) and mitral and tricuspid tissue Doppler annular velocities were obtained. RV 3D volumes and global and regional ejection fraction (3D-RVEF) were determined. RV strains were calculated by 2D-STE and 3D-STE. RV 3D global-free-wall longitudinal strain (3DGFW-RVLS), 2D global-free-wall longitudinal strain (GFW-RVLS), apical-free-wall longitudinal strain, basal-free-wall longitudinal strain, and 3D-RVEF were lower in patients with precapillary PH (P<0.0001) and postcapillary PH (P<0.01) compared to controls. 3DGFW-RVLS (hazard ratio 4.6, 95% CI 2.79 to 8.38, P=0.004) and 3D-RVEF (hazard ratio 5.3, 95% CI 2.85 to 9.89, P=0.002) were independent predictors of mortality. Receiver operating characteristic curves showed that the thresholds offering an adequate compromise between sensitivity and specificity for detecting hemodynamic signs of RV failure were 39% for 3D-RVEF (AUC 0.89), -17% for 3DGFW-RVLS (AUC 0.88), -18% for GFW-RVLS (AUC 0.88), -16% for apical-free-wall longitudinal strain (AUC 0.85), 16 mm for tricuspid annular plane systolic excursion (AUC 0.67), and 38% for RV-FAC (AUC 0.62). CONCLUSIONS: In chronic PH, 3D, 2D-STE and 3D-STE parameters indicate global and regional RV dysfunction that is associated with RV failure hemodynamics better than conventional echo indices.


Subject(s)
Echocardiography, Doppler , Echocardiography, Three-Dimensional , Heart Failure/diagnostic imaging , Hemodynamics , Hypertension, Pulmonary/diagnostic imaging , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Function, Right , Adult , Aged , Area Under Curve , Cardiac Catheterization , Case-Control Studies , Chronic Disease , Female , Heart Failure/etiology , Heart Failure/mortality , Heart Failure/physiopathology , Humans , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/mortality , Hypertension, Pulmonary/physiopathology , Image Interpretation, Computer-Assisted , Male , Middle Aged , Predictive Value of Tests , Prognosis , ROC Curve , Risk Factors , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/mortality , Ventricular Dysfunction, Right/physiopathology
8.
Eur Heart J Cardiovasc Imaging ; 15(12): 1377-85, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25139906

ABSTRACT

AIMS: Percutaneous closure of patent foramen ovale (PFO) in cryptogenic cerebrovascular events is an alternative to medical therapy. The interpretation of residual shunts after implantation of different devices for PFO with different morphologies is controversial. METHODS AND RESULTS: Transcatheter PFO closure was performed in 123 patients with a history of ≥1 paradoxical embolism using three different devices: Amplatzer (n = 46), Figulla Occlutech (n = 41), and Atriasept Cardia (n = 36). Fifty-six patients presented with simple PFO and 67 patients had complex morphologies. All patients were studied with contrast enhanced transesophageal echocardiography (TEE) before interventional procedure and thereafter at 1 and 6 months and every 6-12 months in case of incomplete closure. Definite closure was confirmed in at least two consecutive TEE studies. Various PFO morphologies were identified by TEE before device implantation. The device size to PFO diameter ratio was significantly increased in patients with complex PFO compared with those patients with a simple PFO morphology (P < 0.05). The difference between the closure rate of S-PFO and C-PFO concerning each device type was significant (Amplatzer P = 0.0027, Figulla P = 0.0043, and Atriasept P < 0.01). The mean follow-up period was 3.4 years (median 2.7 years) with a cerebrovascular re-event rate of 2.4% per year. In three patients, thrombi were detected in the 6-month TEE controls and resolved after medical therapy. In three other patients, the implantation of an adjunctive device was necessary for residual shunt. CONCLUSION: In our series of patients, the closure rate was dependent on PFO morphology more than occluder size and type. An adjunctive device was implanted in selected cases.


Subject(s)
Cardiac Catheterization , Echocardiography, Transesophageal/methods , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/therapy , Heart Valve Prosthesis Implantation , Ultrasonography, Interventional , Adult , Aged , Contrast Media , Female , Follow-Up Studies , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Risk Factors , Sensitivity and Specificity , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...