Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Lab Hematol ; 39(2): 147-162, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28297240

ABSTRACT

INTRODUCTION: This study was aimed to compare the analytical performance of traditional and new parameters and morphological flags of CAL-8000 and XN-9000. The automated differential leukocyte count (DIFF profile) and morphological flags were compared with optical microscopy (OM). METHODS: A total of 1025 peripheral blood samples, collected in K3 EDTA tubes, were analyzed by CAL-8000, by XN-9000, and by OM. Within-run imprecision was performed in low cellularity samples. The comparison was made using Spearman's correlation, Passing-Bablok regression, Bland-Altman bias, and Cohen's K test. RESULTS: Within-run imprecision in low cellularity samples yielded reproducible data between the instruments (imprecision was higher than 10% on samples with platelet count <21 × 109 /L using impedance technology). Passing-Bablok regression (CAL-8000 vs. XN-9000) yielded slopes ranging between 0.2 to 1.16 and intercepts from -6.54 to 21.63. The bias for leukocytes parameters ranged from -1.8% to -82.2%, the red blood cell parameters from -2.9% to 3.1%, platelets parameters from -27.8% to 26%, and reticulocyte parameters from -115.3% to 4.5%. The comparison of morphological flags yielded a K value always <0.55. The DIFF profile vs. OM had a Passing-Bablok regression with slopes ranging between 0.34 to 1.00 and intercepts from -0.01% to 0.11 and bias ranging from -42.9% to 2.6% for XN-9000 parameters and from -2.7% to 35.0% for CAL-8000 parameters. The comparison of morphological flags showed a K value ranging from 0.35 to 0.77 for XN-9000 and from 0.17 to 0.54 for CAL-8000. CONCLUSION: Differences exist between the two analyzers, especially in the generation of morphology flags, thus emphasizing the need of pursuing a major degree of harmonization and/or adopting instrument-specific reference ranges.


Subject(s)
Blood Cell Count/instrumentation , Hematology/instrumentation , Automation, Laboratory , Blood Cell Count/standards , Cell Shape , Humans , Reference Values , Reproducibility of Results
2.
Int J Lab Hematol ; 38(1): 90-101, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26547138

ABSTRACT

INTRODUCTION: An accurate and rapid analysis of cells in body fluids (BFs) is important for diagnosis and follow-up in many pathological conditions. We evaluated the analytical performance of the module BF Mindray BC-6800 (BC-6800-BF) for cytometric analysis of ascitic and pleural fluids. METHODS: A total of 99 ascitic and 45 pleural samples were collected and assessed with BC-6800-BF and optical microscopy. This study also includes the evaluation of limit blank (LoB), limit detection (LoD), limit quantitation, (LoQ), carryover, linearity, and diagnostic concordance between the two methods. RESULTS: For TC-BF, LoB was 1 × 10(6) cells/L, LoD was 3 × 10(6) cells/L, and LoQ was 4 × 10(6) cells/L. Linearity was excellent (r(2) = 0.99) and carryover was negligible. TC-BF performed with the two methods showed Pearson's correlation of 0.99 (P < 0.0001), Passing-Bablok regression y = 1.04x - 1.17, and bias 33.7 cells. In ascitic fluids, polymorphonuclear cells (PMN) showed an area under curve (AUC) of 0.98 (P < 0.0001). In pleural fluids, mononuclear cells (MN) and PMN % displayed an AUC of 0.79 (P < 0.0001) and 0.93 (P < 0.0001), respectively. CONCLUSIONS: BC-6800-BF in ascitic and pleural fluids offers rapid and accurate cell and differential counts in clinically relevant concentration ranges. The use of BC-6800-BF may allow to replace routine optical counting, except for samples displaying abnormal cell counts or abnormal DIFF scattergram.


Subject(s)
Body Fluids/cytology , Cell Count/methods , Cell Count/standards , Pleural Effusion/diagnosis , Ascitic Fluid/cytology , Ascitic Fluid/pathology , Automation, Laboratory , Biomarkers , Cell Count/instrumentation , Humans , Pleural Effusion/pathology , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...