Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 164
Filter
1.
Cochrane Database Syst Rev ; 5: CD014715, 2024 05 09.
Article in English | MEDLINE | ID: mdl-38721874

ABSTRACT

BACKGROUND: Prenatal ultrasound is widely used to screen for structural anomalies before birth. While this is traditionally done in the second trimester, there is an increasing use of first-trimester ultrasound for early detection of lethal and certain severe structural anomalies. OBJECTIVES: To evaluate the diagnostic accuracy of ultrasound in detecting fetal structural anomalies before 14 and 24 weeks' gestation in low-risk and unselected pregnant women and to compare the current two main prenatal screening approaches: a single second-trimester scan (single-stage screening) and a first- and second-trimester scan combined (two-stage screening) in terms of anomaly detection before 24 weeks' gestation. SEARCH METHODS: We searched MEDLINE, EMBASE, Science Citation Index Expanded (Web of Science), Social Sciences Citation Index (Web of Science), Arts & Humanities Citation Index and Emerging Sources Citation Index (Web of Science) from 1 January 1997 to 22 July 2022. We limited our search to studies published after 1997 and excluded animal studies, reviews and case reports. No further restrictions were applied. We also screened reference lists and citing articles of each of the included studies. SELECTION CRITERIA: Studies were eligible if they included low-risk or unselected pregnant women undergoing a first- and/or second-trimester fetal anomaly scan, conducted at 11 to 14 or 18 to 24 weeks' gestation, respectively. The reference standard was detection of anomalies at birth or postmortem. DATA COLLECTION AND ANALYSIS: Two review authors independently undertook study selection, quality assessment (QUADAS-2), data extraction and evaluation of the certainty of evidence (GRADE approach). We used univariate random-effects logistic regression models for the meta-analysis of sensitivity and specificity. MAIN RESULTS: Eighty-seven studies covering 7,057,859 fetuses (including 25,202 with structural anomalies) were included. No study was deemed low risk across all QUADAS-2 domains. Main methodological concerns included risk of bias in the reference standard domain and risk of partial verification. Applicability concerns were common in studies evaluating first-trimester scans and two-stage screening in terms of patient selection due to frequent recruitment from single tertiary centres without exclusion of referrals. We reported ultrasound accuracy for fetal structural anomalies overall, by severity, affected organ system and for 46 specific anomalies. Detection rates varied widely across categories, with the highest estimates of sensitivity for thoracic and abdominal wall anomalies and the lowest for gastrointestinal anomalies across all tests. The summary sensitivity of a first-trimester scan was 37.5% for detection of structural anomalies overall (95% confidence interval (CI) 31.1 to 44.3; low-certainty evidence) and 91.3% for lethal anomalies (95% CI 83.9 to 95.5; moderate-certainty evidence), with an overall specificity of 99.9% (95% CI 99.9 to 100; low-certainty evidence). Two-stage screening had a combined sensitivity of 83.8% (95% CI 74.7 to 90.1; low-certainty evidence), while single-stage screening had a sensitivity of 50.5% (95% CI 38.5 to 62.4; very low-certainty evidence). The specificity of two-stage screening was 99.9% (95% CI 99.7 to 100; low-certainty evidence) and for single-stage screening, it was 99.8% (95% CI 99.2 to 100; moderate-certainty evidence). Indirect comparisons suggested superiority of two-stage screening across all analyses regarding sensitivity, with no significant difference in specificity. However, the certainty of the evidence is very low due to the absence of direct comparisons. AUTHORS' CONCLUSIONS: A first-trimester scan has the potential to detect lethal and certain severe anomalies with high accuracy before 14 weeks' gestation, despite its limited overall sensitivity. Conversely, two-stage screening shows high accuracy in detecting most fetal structural anomalies before 24 weeks' gestation with high sensitivity and specificity. In a hypothetical cohort of 100,000 fetuses, the first-trimester scan is expected to correctly identify 113 out of 124 fetuses with lethal anomalies (91.3%) and 665 out of 1776 fetuses with any anomaly (37.5%). However, 79 false-positive diagnoses are anticipated among 98,224 fetuses (0.08%). Two-stage screening is expected to correctly identify 1448 out of 1776 cases of structural anomalies overall (83.8%), with 118 false positives (0.1%). In contrast, single-stage screening is expected to correctly identify 896 out of 1776 cases before 24 weeks' gestation (50.5%), with 205 false-positive diagnoses (0.2%). This represents a difference of 592 fewer correct identifications and 88 more false positives compared to two-stage screening. However, it is crucial to acknowledge the uncertainty surrounding the additional benefits of two-stage versus single-stage screening, as there are no studies directly comparing them. Moreover, the evidence supporting the accuracy of first-trimester ultrasound and two-stage screening approaches primarily originates from studies conducted in single tertiary care facilities, which restricts the generalisability of the results of this meta-analysis to the broader population.


Subject(s)
Pregnancy Trimester, First , Pregnancy Trimester, Second , Ultrasonography, Prenatal , Female , Humans , Pregnancy , Bias , Congenital Abnormalities/diagnostic imaging , Sensitivity and Specificity , Ultrasonography, Prenatal/statistics & numerical data
2.
Article in English | MEDLINE | ID: mdl-38437895

ABSTRACT

OBJECTIVE: To investigate whether racial, ethnic, and linguistic disparities exist at discharge from an acute inpatient rehabilitation facility (IRF) by examining change in Functional Independence Measure (FIM) scores and discharge destination. DESIGN: This is a retrospective study using our IRF's data from the Uniform Data System for Medical Rehabilitation from 2013-2019. FIM scores and discharge destination were compared between race, language, and ethnic groups, with adjustment for patient characteristics. SETTING: An urban hospital with a level 1 trauma center, comprehensive stroke center, and IRF with Commission on Accreditation of Rehabilitation Facilities (CARF) certification. PARTICIPANTS: 2518 patients admitted to the IRF from 2013-2019 (N=2518). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Change in FIM score and discharge destination. RESULTS: After adjusting for covariates, non-White patients and patients with limited English proficiency had significantly lower functional recovery, as measured by smaller changes in FIM scores from IRF admission to discharge. Additionally, both groups were more likely to be discharged home with home health care than to a skilled nursing facility, compared with White and English-speaking patients. Disparities in discharge destination persisted within patients with noncommercial insurance (Medicaid or Medicare) and a stroke diagnosis but not within those who had commercial insurance or a nonstroke diagnosis. CONCLUSIONS: Racial and linguistic disparities were identified within our CARF certified IRF; however, the organization is committed to reducing health care disparities. Next steps will include investigating interventions to reduce disparities.

3.
Fetal Diagn Ther ; 51(3): 225-234, 2024.
Article in English | MEDLINE | ID: mdl-38272013

ABSTRACT

INTRODUCTION: The prenatal detection rate of a right aortic arch (RAA) has increased with the implementation of the three-vessel view (3VV) to the second-trimester anomaly scan formed by the pulmonary artery (PA), aorta (Ao), and superior vena cava (SVC). We examined the value of measuring the distance between PA and Ao in the 3VV in cases with an RAA. METHODS: We conducted a case-control study in which fetuses with an isolated RAA were matched to 3 healthy controls. Using 3VV images, the distances between PA, Ao, and SVC were measured and the ratio between PA to Ao (PAAo) distance and Ao to SVC (AoSVC) distance was calculated. RESULTS: Fifty-four RAA cases and 162 matched controls were included. The mean absolute distance PAAo was 3.1 mm in cases and 1.8 mm in controls (p < 0.001), and the mean PAAo/AoSVC ratio was 2.9 and 1.4, respectively (p < 0.001). The ROC curve of PAAo/AoSVC ratio showed a cut-off point of 1.9 with sensitivity and specificity over 87% for the diagnosis of RAA. CONCLUSIONS: The pulmonary-aortic interspace and the PAAo/AoSVC ratio were significantly larger for RAA cases as compared to controls. If an increased pulmonary-aortic interspace is observed, a PAAo/AoSVC of ≥1.9 can be helpful in the diagnosis of an RAA.


Subject(s)
Aorta, Thoracic , Pulmonary Artery , Ultrasonography, Prenatal , Humans , Female , Case-Control Studies , Pregnancy , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/embryology , Aorta, Thoracic/abnormalities , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/embryology , Pulmonary Artery/abnormalities , Ultrasonography, Prenatal/methods , Adult , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/embryology , Vena Cava, Superior/abnormalities
4.
Acta Crystallogr B Struct Sci Cryst Eng Mater ; 79(Pt 5): 380-391, 2023 Oct 01.
Article in English | MEDLINE | ID: mdl-37669152

ABSTRACT

Five different electron density datasets obtained from conventional and synchrotron single crystal X-ray diffraction experiments are compared. The general aim of the study is to investigate the quality of data for electron density analysis from current state-of-the-art conventional sources, and to see how the data perform in comparison with high-quality synchrotron data. A molecular crystal of melamine was selected as the test compound due to its ability to form excellent single crystals, the light atom content, and an advantageous suitability factor of 3.6 for electron density modeling. These features make melamine an optimal system for conventional X-ray diffractometers since the inherent advantages of synchrotron sources such as short wavelength and high intensity are less critical in this case. Data were obtained at 100 K from new in-house diffractometers Rigaku Synergy-S (Mo and Ag source, HyPix100 detector) and Stoe Stadivari (Mo source, EIGER2 1M CdTe detector), and an older Oxford Diffraction Supernova (Mo source, Atlas CCD detector). The synchrotron data were obtained at 25 K from BL02B1 beamline at SPring-8 in Japan (λ = 0.2480 Å, Pilatus3 X 1M CdTe detector). The five datasets were compared on general quality parameters such as resolution, ⟨I/σ⟩, redundancy and R factors, as well as the more model specific fractal dimension plot and residual density maps. Comparison of the extracted electron densities reveals that all datasets can provide reliable multipole models, which overall convey similar chemical information. However, the new laboratory X-ray diffractometers with advanced pixel detector technology clearly measure data with significantly less noise and much higher reliability giving densities of higher quality, compared to the older instrument. The synchrotron data have higher resolution and lower measurement temperature, and they allow for finer details to be modeled (e.g. hydrogen κ parameters).

5.
Angew Chem Int Ed Engl ; 62(45): e202311044, 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-37718313

ABSTRACT

We report thermochromism in crystals of diphenyl diselenide (dpdSe) and diphenyl ditelluride (dpdTe), which is at variance with the commonly known mechanisms of thermochromism in molecular crystals. Variable temperature neutron diffraction studies indicated no conformational change, tautomerization or phase transition between 100 K and 295 K. High-pressure crystallography studies indicated no associated piezochromism in dpdSe and dpdTe crystals. The evolution of the crystal structures and their electronic band structure with pressure and temperature reveal the contributions of intramolecular and intermolecular factors towards the origin of thermochromism-especially the intermolecular Se⋅⋅⋅Se and Te⋅⋅⋅Te chalcogen bonds and torsional modes of vibrations around the dynamic Se-Se and Te-Te bonds. Further, a co-crystal of dpdSe with iodine (dpdSe-I2 ) and an alloy crystal of dpdSe and dpdTe implied a predominantly intramolecular origin of the observed thermochromism associated with vibronic coupling.

6.
Eur J Obstet Gynecol Reprod Biol ; 287: 130-136, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37311275

ABSTRACT

OBJECTIVE: First trimester non-invasive prenatal testing (NIPT) provides pregnant women with a reliable, non-invasive method to screen for fetal aneuploidies. In the Netherlands, there is a nationwide prenatal screening program in which pregnant women and their partners are counseled about their options around 10 weeks of pregnancy. The first trimester and second trimester scan are fully reimbursed but the NIPT has an own financial contribution of €175 per participant, irrespective of type of insurance. The arguments for this own contribution are fear of uncritical use of NIPT or routinization. NIPT has a relatively stable uptake of 51%, against over 95% for second trimester anomaly scan. We aimed to explore the effect of this financial contribution on the decision to opt out of NIPT. STUDY DESIGN: We performed a survey among 350 pregnant women undergoing a second trimester anomaly scan in our center, Amsterdam UMC, between January 2021 and April 2022. All pregnant women who declined NIPT in the first trimester, were asked to participate and answered 11-13 questions about the decision-making process, the reasons to opt out and the financial contribution. RESULTS: Information about NIPT was desired in 92% of women and 96% felt sufficiently informed. Most women took the decision not to perform NIPT with their partner and did not experience difficulties in taking this decision. The most important reason to decline NIPT was: "Every child is welcome" (69%). "The test was too expensive" was answered in 12% and was significantly correlated with lower maternal age. Additionally, one in five women (19%) said they would have done NIPT if it had been for free, which was significantly higher in younger women. CONCLUSIONS: The own financial contribution plays a role in the decision-making to decline NIPT and partly explains the low uptake in the Netherlands. This suggests that there is no equal access to fetal aneuploidy screening. To overcome this inequality, this own contribution should be abandoned. We speculate that this will have a positive effect on the uptake, which will increase to at least 70% and potentially 94%.


Subject(s)
Gift Giving , Prenatal Diagnosis , Child , Pregnancy , Female , Humans , Prenatal Diagnosis/methods , Pregnant Women , Maternal Age , Pregnancy Trimester, First , Aneuploidy
7.
Am J Obstet Gynecol MFM ; 5(8): 101023, 2023 08.
Article in English | MEDLINE | ID: mdl-37220848

ABSTRACT

BACKGROUND: Congenital heart defects are the most common congenital anomaly. Despite the increasing survival of these children, there is still an increased incidence of fetal demise, frequently attributed to cardiac failure. Considering that abnormal placental development has been described in congenital heart disease, our hypothesis is that placental insufficiency may contribute to fetal death in congenital heart disease. OBJECTIVE: This study aimed to assess cases with fetal congenital heart disease and intrauterine demise, and analyze factors that are related to the demise. STUDY DESIGN: All congenital heart disease cases diagnosed prenatally during the period January 2002 to January 2021 were selected from the regional prospective congenital heart disease registry, PRECOR. Multiple pregnancies and pregnancies with fetal trisomy 13 or 18, triploidy, and Turner's syndrome were excluded from the analysis, because fetal demise is attributed to the chromosomal abnormality in these cases. Cases were categorized into 4 groups based on the possible cause of fetal death as follows: cardiac failure, additional (genetic) diagnosis, placental insufficiency, and a group in which no cause was found. A separate analysis was performed for isolated congenital heart disease cases. RESULTS: Of the 4806 cases in the PRECOR registry, 112 had fetal demise, of which 43 were excluded from the analysis (13 multiple pregnancies, 30 genetic). Of these, 47.8% were most likely related to cardiac failure, 42.0% to another (genetic) diagnosis, and 10.1% to placental insufficiency. No cases were allocated to the group with an unknown cause. Only 47.8% of the cases had isolated congenital heart disease, and in this group 21.2% was most likely related to placental insufficiency. CONCLUSION: This study shows that in addition to cardiac failure and other (genetic) diagnoses, placental factors play an important role in fetal demise in congenital heart disease, especially in cases of isolated heart defects. Therefore, these findings support the importance of regular ultrasonographic assessment of fetal growth and placental function in fetal congenital heart disease.


Subject(s)
Fetal Diseases , Heart Defects, Congenital , Heart Failure , Placental Insufficiency , Child , Pregnancy , Female , Humans , Placental Insufficiency/epidemiology , Placenta , Prospective Studies , Fetal Death/etiology , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/epidemiology
8.
Prenat Diagn ; 43(5): 629-638, 2023 05.
Article in English | MEDLINE | ID: mdl-36738444

ABSTRACT

OBJECTIVES: To determine the proportion of children that require surgery in the first year of life and thereafter in order to improve the counseling of parents with a fetus with a right aortic arch (RAA). METHODS: Fetuses diagnosed with isolated RAA, defined as the absence of intra- or extracardiac anomalies, between 2007 and 2021 were extracted from the prospective registry PRECOR. RESULTS: In total, 110 fetuses were included, 92 with a prenatal diagnosis of RAA and 18 with double aortic arch (DAA). The prevalence of 22q11 deletion syndrome was 5.5%. Six pregnancies were terminated and five cases were false-positive; therefore, the follow-up consisted of 99 neonates. Surgery was performed in 10 infants (10%) in the first year of life. In total, 25 (25%) children had surgery at a mean age of 17 months. Eight of these 25 (32%) had a DAA. Only one child, with a DAA, required surgery in the first week of life due to obstructive stridor. CONCLUSIONS: Children with a prenatally diagnosed RAA are at a low risk of acute respiratory postnatal problems. Delivery in a hospital with neonatal intensive care and pediatric cardiothoracic facilities seems only indicated in cases with suspected DAA. Expectant parents should be informed that presently 25% of the children need elective surgery and only incidentally due to acute respiratory distress.


Subject(s)
Aortic Arch Syndromes , Vascular Ring , Pregnancy , Infant , Infant, Newborn , Female , Humans , Child , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Ultrasonography, Prenatal , Retrospective Studies , Prenatal Diagnosis , Aortic Arch Syndromes/diagnostic imaging , Aortic Arch Syndromes/surgery
9.
Adv Mater ; 35(13): e2208220, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36630711

ABSTRACT

Determination of crystal structures of nanocrystalline or amorphous compounds is a great challenge in solid-state chemistry and physics. Pair distribution function (PDF) analysis of X-ray or neutron total scattering data has proven to be a key element in tackling this challenge. However, in most cases, a reliable structural motif is needed as a starting configuration for structure refinements. Here, an algorithm that is able to determine the crystal structure of an unknown compound by means of an on-the-fly trained machine learning model, which combines density functional theory calculations with comparison of calculated and measured PDFs for global optimization in an artificial landscape, is presented. Due to the nature of this landscape, even metastable configurations and stacking disorders can be identified.

10.
Angew Chem Int Ed Engl ; 62(13): e202218458, 2023 Mar 20.
Article in English | MEDLINE | ID: mdl-36696593

ABSTRACT

Loosely bonded ("rattling") atoms with s2 lone pair electrons are usually associated with strong anharmonicity and unexpectedly low thermal conductivity, yet their detailed correlation remains largely unknown. Here we resolve this correlation in thermoelectric InTe by combining chemical bonding analysis, inelastic X-ray and neutron scattering, and first principles phonon calculations. We successfully probe soft low-lying transverse phonons dominated by large In1+ z-axis motions, and their giant anharmonicity. We show that the highly anharmonic phonons arise from the dynamic lone pair expression with unstable occupied antibonding states induced by the covalency between delocalized In1+ 5s2 lone pair electrons and Te 5p states. This work pinpoints the microscopic origin of strong anharmonicity driven by rattling atoms with stereochemical lone pair activity, important for designing efficient materials for thermoelectric energy conversion.

11.
Prenat Diagn ; 43(5): 620-628, 2023 05.
Article in English | MEDLINE | ID: mdl-36549919

ABSTRACT

OBJECTIVE: We aimed to assess current prenatal detection rate (DR) of aortic coarctation (CoA) and its impact on neonatal outcome in the Netherlands to evaluate the efficacy of the Dutch screening protocol in which the cardiac four-chamber view, outflow tracts and three-vessel view are compulsory. METHODS: All prenatally and postnatally diagnosed CoA cases between 2012 and 2021 were extracted from our PRECOR-registry. Annual DRs were calculated with a focus on the trend over time and attributing factors for detection. Postnatal outcome was compared between prenatally detected and undetected cases. RESULTS: 49/116 cases (42.2%) were detected prenatally. A higher chance of detection was found for cases with extracardiac malformations (71.4%; p = 0.001) and the more severe cases with an aortic arch hypoplasia and/or ventricular septal defect (63.2%; p = 0.001). Time-trend analysis showed no improvement in DR over time (p = 0.33). Undetected cases presented with acute circulatory shock in 20.9% and were more likely to have severe lactic acidosis (p = 0.02) and impaired cardiac function (p < 0.001) before surgery. CONCLUSION: Even in a well-organized screening program, the DR of CoA still requires improvement, especially in isolated cases. The increased risk of severe lactic acidosis in undetected cases stresses the need for urgent additions to the current screening program, such as implementation of the three-vessel trachea view and measurement of outflow tracts.


Subject(s)
Acidosis, Lactic , Aortic Coarctation , Heart Septal Defects, Ventricular , Pregnancy , Infant, Newborn , Female , Humans , Aortic Coarctation/diagnostic imaging , Echocardiography/methods , Netherlands/epidemiology , Ultrasonography, Prenatal/methods , Retrospective Studies
12.
Acta Crystallogr A Found Adv ; 78(Pt 6): 515, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36318075

ABSTRACT

The name of the third author of the article by Koch et al. [Acta Cryst. (2021). A77, 611-636] is corrected.

13.
Prenat Diagn ; 42(11): 1358-1367, 2022 10.
Article in English | MEDLINE | ID: mdl-36097374

ABSTRACT

OBJECTIVE: We aimed to evaluate the additional value of advanced fetal anatomical assessment by ultrasound in pregnancies with twice inconclusive noninvasive testing (NIPT) due to low fetal fraction (FF). METHODS: We performed a multicenter-retrospective study between 2017 and 2020 including 311 pregnancies with twice inconclusive NIPT due to low FF ≤ 1%. Women were offered invasive testing and advanced fetal anatomical assessment at ≤18 weeks' gestation. Ultrasound findings, genetic testing, and pregnancy/postnatal outcomes were evaluated. RESULTS: Ninety-two/311 (29.6%) women underwent invasive testing. Structural anomalies were diagnosed in 13/311 (4.2%) pregnancies (nine at the first scan and four at follow-up). In 6/13 (46.2%) cases, genetic aberrations were confirmed (one case of Trisomy 13 (detectable by NIPT), two of Triploidy, one of 16q12-deletion, HCN4-mutation and UPD(16) (nondetectable by NIPT). Genetic aberrations were found in 4/298 (1.3%) structurallynormal pregnancies (one 47XYY, two microscopic aberrations, one monogenic disorder found postpartum). Structural anomalies in genetically normal fetuses (2.0%) were not more prevalent compared to the general pregnant population (OR 1.0 [0.4-2.2]). CONCLUSION: In pregnancies with twice inconclusive NIPT due to low FF, fetal structural anomalies are not more prevalent than in the general obstetric population. The detailed anatomical assessment has the added value to detect phenotypical features suggestive of chromosomal/genetic aberrations and identify pregnancies where advanced genetic testing may be indicated.


Subject(s)
Cell-Free Nucleic Acids , Chromosome Aberrations , Female , Humans , Hyperpolarization-Activated Cyclic Nucleotide-Gated Channels/genetics , Male , Pregnancy , Pregnancy Trimester, First , Prenatal Diagnosis , Retrospective Studies , Trisomy/diagnosis , Trisomy/genetics , Ultrasonography , Ultrasonography, Prenatal
14.
Chemistry ; 28(54): e202201295, 2022 Sep 27.
Article in English | MEDLINE | ID: mdl-35760733

ABSTRACT

Melamine is a precursor and building block for graphitic carbon nitride (g-CN) materials, a group of layered materials showing great promise for catalytic applications. The synthetic pathway to g-CN includes a polycondensation reaction of melamine by evaporation of ammonia. Melamine molecules in the crystal organize into wave-like planes with an interlayer distance of 3.3 Šsimilar to that of g-CN. Here we present an extensive investigation of the experimental electron density of melamine obtained from modelling of synchrotron radiation X-ray single-crystal diffraction data measured at 25 K with special focus on the molecular geometry and intermolecular interactions. Both intra- and interlayer structures are dominated by hydrogen bonding and π-interactions. Theoretical gas-phase optimizations of the experimental molecular geometry show that bond lengths and angles for atoms in the same chemical environment (C-N bonds in the ring, amine groups) differ significantly more for the experimental geometry than for the gas-phase-optimized geometries, indicating that intermolecular interactions in the crystal affects the molecular geometry. In the experimental crystal geometry, one amine group has significantly more sp3 -like character than the others, hinting at a possible formation mechanism of g-CN. Topological analysis and energy frameworks show that the nitrogen atom in this amine group participates in weak intralayer hydrogen bonding. We hypothesize that melamine condenses to g-CN within the layers and that the unique amine group plays a key role in the condensation process.

15.
Nano Lett ; 22(4): 1566-1572, 2022 02 23.
Article in English | MEDLINE | ID: mdl-35130696

ABSTRACT

Radiotherapy is a well-established and important treatment for cancer tumors, and advanced technologies can deliver doses in complex three-dimensional geometries tailored to each patient's specific anatomy. A 3D dosimeter, based on optically stimulated luminescence (OSL), could provide a high accuracy and reusable tool for verifying such dose delivery. Nanoparticles of an OSL material embedded in a transparent matrix have previously been proposed as an inexpensive dosimeter, which can be read out using laser-based methods. Here, we show that Cu-doped LiF nanocubes (nano-LiF:Cu) are excellent candidates for 3D OSL dosimetry owing to their high sensitivity, dose linearity, and stability at ambient conditions. We demonstrate a scalable synthesis technique producing a material with the attractive properties of a single dosimetric trap and a single near-ultraviolet emission line well separated from visible-light stimulation sources. The observed transparency and light yield of silicone sheets with embedded nanocubes hold promise for future 3D OSL-based dosimetry.


Subject(s)
Nanocomposites , Optically Stimulated Luminescence Dosimetry , Humans , Luminescence , Optically Stimulated Luminescence Dosimetry/methods
16.
Nat Commun ; 12(1): 6709, 2021 Nov 18.
Article in English | MEDLINE | ID: mdl-34795243

ABSTRACT

Structural disorder, highly effective in reducing thermal conductivity, is important in technological applications such as thermal barrier coatings and thermoelectrics. In particular, interstitial, disordered, diffusive atoms are common in complex crystal structures with ultralow thermal conductivity, but are rarely found in simple crystalline solids. Combining single-crystal synchrotron X-ray diffraction, the maximum entropy method, diffuse scattering, and theoretical calculations, here we report the direct observation of one-dimensional disordered In1+ chains in a simple chain-like thermoelectric InTe, which contains a significant In1+ vacancy along with interstitial indium sites. Intriguingly, the disordered In1+ chains undergo a static-dynamic transition with increasing temperature to form a one-dimensional diffusion channel, which is attributed to a low In1+-ion migration energy barrier along the c direction, a general feature in many other TlSe-type compounds. Our work provides a basis towards understanding ultralow thermal conductivity with weak temperature dependence in TlSe-type chain-like materials.

17.
Acta Crystallogr A Found Adv ; 77(Pt 6): 611-636, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34726636

ABSTRACT

Data reduction and correction steps and processed data reproducibility in the emerging single-crystal total-scattering-based technique of three-dimensional differential atomic pair distribution function (3D-ΔPDF) analysis are explored. All steps from sample measurement to data processing are outlined using a crystal of CuIr2S4 as an example, studied in a setup equipped with a high-energy X-ray beam and a flat-panel area detector. Computational overhead as pertains to data sampling and the associated data-processing steps is also discussed. Various aspects of the final 3D-ΔPDF reproducibility are explicitly tested by varying the data-processing order and included steps, and by carrying out a crystal-to-crystal data comparison. Situations in which the 3D-ΔPDF is robust are identified, and caution against a few particular cases which can lead to inconsistent 3D-ΔPDFs is noted. Although not all the approaches applied herein will be valid across all systems, and a more in-depth analysis of some of the effects of the data-processing steps may still needed, the methods collected herein represent the start of a more systematic discussion about data processing and corrections in this field.

18.
Chem Sci ; 12(37): 12391-12399, 2021 Sep 29.
Article in English | MEDLINE | ID: mdl-34603669

ABSTRACT

Alloy formation is ubiquitous in inorganic materials science, and it strongly depends on the similarity between the alloyed atoms. Since molecules have widely different shapes, sizes and bonding properties, it is highly challenging to make alloyed molecular crystals. Here we report the generation of homogenous molecular alloys of organic light emitting diode materials that leads to tuning in their bandgaps and fluorescence emission. Tris(8-hydroxyquinolinato)aluminium (Alq3) and its Ga, In and Cr analogues (Gaq3, Inq3, and Crq3) form homogeneous mixed crystal phases thereby resulting in binary, ternary and even quaternary molecular alloys. The M x M'(1-x)q3 alloy crystals are investigated using X-ray diffraction, energy dispersive X-ray spectroscopy and Raman spectroscopy on single crystal samples, and photoluminescence properties are measured on the exact same single crystal specimens. The different series of alloys exhibit distinct trends in their optical bandgaps compared with their parent crystals. In the Al x Ga(1-x)q3 alloys the emission wavelengths lie in between those of the parent crystals, while the Al x In(1-x)q3 and Ga x In(1-x)q3 alloys have red shifts. Intriguingly, efficient fluorescence quenching is observed for the M x Cr(1-x)q3 alloys (M = Al, Ga) revealing the effect of paramagnetic molecular doping, and corroborating the molecular scale phase homogeneity.

19.
Prenat Diagn ; 41(13): 1685-1693, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34592002

ABSTRACT

OBJECTIVES: In this era of non-invasive-prenatal testing (NIPT), when dating scans are usually performed around 10 weeks of gestation, an increased NT before the official established timeframe (CRL between 45 and 84 mm) may be encountered. Information on management of these pregnancies is limited. Therefore, we evaluated the relationship between an early increased NT and adverse pregnancy outcome. Secondary, we evaluated the rate of chromosomal anomalies that might have been missed in first trimester should solely NIPT be performed as first-tier test, and the rate of adverse pregnancy outcome if NT normalizes before 14 weeks. METHODS: We performed a retrospective cohort study that included all pregnancies between January 1, 2007 and June 1, 2020 in Amsterdam UMC locations AMC and VUmc. We included fetuses with a crown-rump length (CRL) < 45 mm (∼11 weeks) and a nuchal translucency (NT) measurement ≥2.5 mm. Fetuses referred with an early increased NT and a major fetal anomaly at the dating scan were excluded, as were cases of parents with a family history of monogenetic disease(s) or recognized carriers of a balanced translocation. RESULTS: We included 120 fetuses of which 66.7% (80/120) had an adverse pregnancy outcome. Congenital anomalies were present in 56.7% (68/120), 45.8% (55/120) had a chromosomal anomaly. The prevalence of congenital anomalies was 30.3% in fetuses with NT 2.5-3.4 mm compared to 66.7% with NT ≥ 3.5 mm (p < 0.001). 16.7% (20/120) had a chromosomal anomaly that might have been missed by conventional NIPT in first trimester. We found an adverse pregnancy outcome of 24% in the group with a normalized NT compared to 78.1% in the group with a persistently increased NT (p < 0.001). CONCLUSION: An early increased NT should make the sonographer alert. In this selected cohort, an early increased NT was associated with a high probability of having an adverse pregnancy outcome. Regardless of CRL, we deem that an early increased NT ≥ 3.5 mm warrants referral to a Fetal Medicine Unit for an extensive work-up. NT normalization seems favorable, but a prospective study should define the appropriate work-up for NT in the lower range (2.5-3.4 mm).


Subject(s)
Gestational Age , Nuchal Translucency Measurement/classification , Referral and Consultation/standards , Adult , Cohort Studies , Female , Humans , Nuchal Translucency Measurement/statistics & numerical data , Pregnancy , Pregnancy Outcome/epidemiology , Prospective Studies , Referral and Consultation/statistics & numerical data , Retrospective Studies , Ultrasonography, Prenatal/methods
20.
ACS Appl Mater Interfaces ; 13(38): 45708-45716, 2021 Sep 29.
Article in English | MEDLINE | ID: mdl-34544237

ABSTRACT

ß-Zn4Sb3 is a cheap nontoxic high-performance thermoelectric material, which unfortunately suffers from stability issues because of zinc migration in thermal and electrical gradients. Here, the thermoelectric properties and thermal stability of ß-Zn4Sb3 mixed with varying sizes and weight percentages of TiO2 nanoparticles are investigated. Furthermore, the stability of pressed ß-Zn4Sb3-TiO2 nanocomposite pellets is investigated by measuring high-energy synchrotron powder X-ray diffraction (PXRD) data during operating conditions using the Aarhus thermoelectric operando setup (ATOS). Through these studies, it is determined that TiO2 nanoparticle addition in pressed pellets of ß-Zn4Sb3 does not prevent Zn migration, and even though effects are seen in the thermal conductivity and electrical resistivity, the overall zT remains unchanged regardless of TiO2 nanoinclusions. For the present samples, the Seebeck coefficients are unaffected by the addition of nanoparticles, and thus, there is no observed energy-filtering effect. The operando PXRD data reveal that the TiO2 nanoinclusions lower the degradation rate by up to 75%, but all samples eventually decompose. This is corroborated by long-term stability tests performed using a thermal gradient. In conclusion, TiO2 nanoinclusions do not degrade the excellent thermoelectric properties of ß-Zn4Sb3, but the stabilizing effect is not sufficient for establishing long-term operating stability.

SELECTION OF CITATIONS
SEARCH DETAIL
...