Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Herz ; 40 Suppl 3: 247-53, 2015 May.
Article in English | MEDLINE | ID: mdl-25277222

ABSTRACT

BACKGROUND: The median dose area products (DAP) and effective doses (ED) of patients arising from coronary angiography (CA) are considerable: According the 2013 National German Registry, they amount to 19.8 Gy × cm(2) and 4.0 mSv, respectively. METHODS: We investigated the feasibility of prospective electrocardiogram (ECG)-gated coronary angiography (CA)-a novel technique in invasive cardiology-with respect to possible reduction in irradiation effects. Instead of universally fix-rated radiographic acquisition within 7.5-15 frames/s, one single frame/heartbeat was triggered toward the diastolic moment immediately before atrial contraction (77 % of ECG-RR interval) most likely to provide motion-free and hence optimized resolution of the coronary tree. For 200 patients (body mass index 27.8 kg/m(2), age 67.5 years, male 55 %, 68 bpm) undergoing ECG-gated CA, we measured various median (interquartile range) parameters for radiation exposure. RESULTS: The total DAP was 0.64 (0.46-1.00), radiographic fraction was 0.30 (0.19-0.43), and fluoroscopic fraction was 0.35 (0.21-0.57) Gy × cm(2). Radiographic imaging occurred within 21.7 s (17.1-26.3), with 25 frames (20-30) over the course of 7 runs (6-8). Fluoroscopy time was 119 s (94-141). Radiographic DAP was 12.6 mGy × cm(2)/frame and 13.8 mGy × cm(2)/s. Fluoroscopic DAP was 0.8 mGy × cm(2)/pulse and 3.1 mGy × cm(2)/s. Patient reference point air kerma was 17.0 mGy (11.1-28.1) and contrast volume was 70 ml (60-85). CONCLUSION: In conclusion, invasive ECG-gated coronary imaging is feasible in clinical routine and enables patient EDs of approx. 3 % of typical values in invasive cardiology: 0.13 mSv (0.09-0.20).


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Radiation Exposure/analysis , Surgery, Computer-Assisted/methods , Aged , Cardiac-Gated Imaging Techniques/instrumentation , Coronary Angiography/instrumentation , Female , Humans , Male , Radiation Dosage , Radiation Exposure/prevention & control , Radiation Protection/instrumentation , Radiation Protection/methods , Relative Biological Effectiveness , Reproducibility of Results , Sensitivity and Specificity , Surgery, Computer-Assisted/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...