Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
J Chromatogr A ; 1735: 465295, 2024 Oct 25.
Article in English | MEDLINE | ID: mdl-39236359

ABSTRACT

A new method was evaluated and developed for the analysis of pesticides in sandy-loam soil by direct-immersion solid phase microextraction (DI-SPME) followed by gas chromatography tandem-mass spectrometry (GC-MS/MS) determination. Ten pesticides were selected based on a literature survey of the compounds reported to be present in EU soils. The extraction was performed using SPME LC-Tips, a new SPME configuration with the coated fibers attached to a disposable and easy-to-handle micropipette tip, which was immersed into a soil slurry made by the addition of an aqueous solution to the soil sample. Ten experimental parameters were evaluated with a Plackett-Burman design, after which the extraction time and percentage of organic solvent in the aqueous extraction were optimized separately. The two fiber chemistries available (PDMS/DVB and C18) were evaluated in parallel for the entire work. In the final method, slurry samples were made by adding an aqueous solution (6 % methanol v/v) to 2 g of soil. The fiber was conditioned and then inserted, for extraction, into the samples, stirred by a magnetic bar. Afterwards, the analytes were desorbed onto 100 µL of methanol. After the addition of analyte protectants (ethylglycerol, gulonolactone, and sorbitol) the extract was injected into the GC-MS/MS system. Isotopically labelled penconazole was used as internal standard. A calibration was performed by extracting spiked soil with analyte concentrations of 0.1-50 µg/kg. Coefficients of determination of the linear calibration were between 0.94-0.98 for the PDMS/DVB and 0.92-0.99 for the C18. Limits of detection range between 0.01-10 µg/kg for the PDMS/DVB and 0.1-10 µg/kg for the C18. Overall, the C18 analytically outperformed the PDMS/DVB but required a longer extraction time (120 min vs 75 min for the PDMS/DVB). This method allows automation and generates low residual toxic waste, having the potential to be introduced as a greener and simpler alternative to currently used sample preparation methodologies.


Subject(s)
Gas Chromatography-Mass Spectrometry , Pesticides , Soil Pollutants , Soil , Solid Phase Microextraction , Tandem Mass Spectrometry , Solid Phase Microextraction/methods , Gas Chromatography-Mass Spectrometry/methods , Soil Pollutants/analysis , Soil Pollutants/isolation & purification , Tandem Mass Spectrometry/methods , Soil/chemistry , Pesticides/analysis , Pesticides/isolation & purification , Limit of Detection , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL