Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Language
Publication year range
1.
Iran Endod J ; 15(3): 124-139, 2020.
Article in English | MEDLINE | ID: mdl-36703804

ABSTRACT

Introduction: Irregularities and defects on NiTi endodontic instruments originating from the manufacturing process can lead to the structural collapse and fracture of these instruments during treatment. To assess the cause of instrument wear and fracture, as well as increasing fracture incidence, destructive and non-destructive methods have been used for the analysis of surfaces and internal structures of new and used NiTi instruments. The aim of this systematic review was to undertake a detailed analysis of the methods used to evaluate the surface and internal microstructure of endodontic instruments. Methods and Materials: The scientific literature was comprehensively and systematically searched in the MEDLINE (PubMed), Web of Science, Cochrane Library, Scopus, and LILACS/BBO databases for studies published up to June 9, 2019. The eligibility criteria was based on the PICO (Patient, Intervention, Comparison, and Outcome) strategy with the question "What is the best method for structural analysis of endodontic files?" Two aspects were considered for inclusion in this study: (i) endodontic instruments and (ii) methods for structural analysis of NiTi instruments. . The systematic review was performed according to the PRISMA statement. Results: Based on the inclusion criteria, 94 articles were selected. The results showed that although specific methods have been used for qualitative and/or quantitative structural analysis of NiTi instruments, no study addressed both the surface and internal structure of the instruments at the same time. According to this review, the need to compare the methodologies used in the selected articles has been identified; however, each type of method used has its own limitation on the analysis of both the surface and the internal structure of the instruments. Conclusions: The comparison between the different types of methodologies used in the studies revealed the reliability and the limitations of the methods employed for structural analysis of endodontic instruments; thus assisting us in determining their validity.

2.
Dent Mater ; 35(2): 195-205, 2019 02.
Article in English | MEDLINE | ID: mdl-30527507

ABSTRACT

OBJECTIVES: The increased demand for esthetics and minimally invasive tooth restorations resulted in a rapid development of adhesive dentistry. However, much controversy remains about the safe use and cytotoxic effects of different groups of dental adhesives. The present study performed a systematic review to identify the answer to the following question: are self-etch adhesives more cytotoxic than those employing the etch-and-rinse system? METHODS: This systematic review was performed in accordance with the PRISMA statement; a quality assessment for in vitro studies was conducted using the ToxRTool. Specific search strategies were developed and performed in the electronic databases MEDLINE via PubMed, Cochrane Library, Scopus, Web of Science, and LILACS/BBO. After removal of duplicated studies and application of the exclusion criteria, ten eligible articles were selected and submitted to a qualitative descriptive analysis comparing both groups of dental adhesives. Most in vitro test systems employed pulp cells or gingival fibroblasts. RESULTS: The methodologies presented great variability regarding the exposure to the test materials. Only four studies assessed the role of the degree of conversion of the materials in their toxicity, with conflicting results. SIGNIFICANCE: While the lack of methodological standardization among the studies still hinders the establishment of a relationship between type of dental adhesive and toxicity, studies employing dentin barrier systems indicate greater cytotoxicity for etch-and-rinse adhesives.


Subject(s)
Dental Bonding , Dental Cements , Adhesives , Dental Pulp , Dentin , Dentin-Bonding Agents , Materials Testing , Resin Cements
3.
Braz Oral Res ; 31: e74, 2017 Sep 28.
Article in English | MEDLINE | ID: mdl-29019548

ABSTRACT

The aim of this study was to undertake a qualitative and quantitative assessment of nanoscale alterations and wear on the surfaces of nickel-titanium (NiTi) endodontic instruments, before and after use, through a high-resolution, noncontact, three-dimensional optical profiler, and to verify the accuracy of the evaluation method. Cutting blade surfaces of two different brands of NiTi endodontic instruments, Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were examined and compared before and after two uses in simulated root canals made in clear resin blocks. The analyses were performed on three-dimensional images which were obtained from surface areas measuring 211 × 211 µm, located 3 mm from their tips. The quantitative evaluation of the samples was conducted before and after the first and second usage, by the recordings of three amplitude parameters. The data were subjected to statistical analysis at a 5% level of significance. The results revealed statistically significant increases in the surface wear of both instruments groups after the second use. The presence of irregularities was found on the surface topography of all the instruments, before and after use. Regardless of the evaluation stage, most of the defects were observed in the WaveOne instruments. The three-dimensional technique was suitable and effective for the accurate investigation of the same surfaces of the instruments in different periods of time.


Subject(s)
Endodontics/instrumentation , Nickel/chemistry , Root Canal Preparation/instrumentation , Titanium/chemistry , Equipment Design , Humans , Imaging, Three-Dimensional/methods , Interferometry/methods , Materials Testing , Reference Values , Reproducibility of Results , Surface Properties , Time Factors
4.
Braz. oral res. (Online) ; 31: e74, 2017. tab, graf
Article in English | LILACS | ID: biblio-952085

ABSTRACT

Abstract The aim of this study was to undertake a qualitative and quantitative assessment of nanoscale alterations and wear on the surfaces of nickel-titanium (NiTi) endodontic instruments, before and after use, through a high-resolution, noncontact, three-dimensional optical profiler, and to verify the accuracy of the evaluation method. Cutting blade surfaces of two different brands of NiTi endodontic instruments, Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were examined and compared before and after two uses in simulated root canals made in clear resin blocks. The analyses were performed on three-dimensional images which were obtained from surface areas measuring 211 × 211 µm, located 3 mm from their tips. The quantitative evaluation of the samples was conducted before and after the first and second usage, by the recordings of three amplitude parameters. The data were subjected to statistical analysis at a 5% level of significance. The results revealed statistically significant increases in the surface wear of both instruments groups after the second use. The presence of irregularities was found on the surface topography of all the instruments, before and after use. Regardless of the evaluation stage, most of the defects were observed in the WaveOne instruments. The three-dimensional technique was suitable and effective for the accurate investigation of the same surfaces of the instruments in different periods of time.


Subject(s)
Humans , Titanium/chemistry , Root Canal Preparation/instrumentation , Endodontics/instrumentation , Nickel/chemistry , Reference Values , Surface Properties , Time Factors , Materials Testing , Reproducibility of Results , Imaging, Three-Dimensional/methods , Equipment Design , Interferometry/methods
5.
Braz Oral Res ; 29: 1-7, 2015.
Article in English | MEDLINE | ID: mdl-26486768

ABSTRACT

The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05). The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05). The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments' geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.


Subject(s)
Dental Instruments , Root Canal Preparation/instrumentation , Dental Alloys , Dental Stress Analysis , Equipment Design , Materials Testing , Microscopy, Electron, Scanning , Stress, Mechanical
6.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, graf
Article in English | LILACS | ID: lil-777181

ABSTRACT

The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05). The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05). The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments’ geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.


Subject(s)
Dental Instruments , Root Canal Preparation/instrumentation , Dental Alloys , Dental Stress Analysis , Equipment Design , Materials Testing , Microscopy, Electron, Scanning , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...