ABSTRACT
This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.05 e #25/~), Reciproc Blue (RB; R25), and MTwo (M2; #10/.04, #15/.05, #20/.06 e #25/.06). The RL was defined as the apical limit, and 2.5% sodium hypochlorite irrigating solution was chosen. After the access cavity (RL 1), cervical flaring (RL 2), and complete chemical-mechanical preparation (RL 3), the RL was evaluated. The RL was evaluated by a blind examiner with the aid of a microscope (16x) placing the endodontic file stop at the coronary reference. When comparing length measurements, the RL was shorter before instrumentation than that after instrumentation. A reduction of 0.65 mm (HF), 0.61 mm (RB), and 0.48 mm (M2) was observed. However, among groups, no statistical differences were found (p > 0.05). Under the conditions tested, it can be inferred that all mechanical systems provoked RL variations, which emphasizes the need for constant verification of the odontometry, mainly before root canal obturation.
Subject(s)
Dental Pulp Cavity , Root Canal Preparation , Dental Instruments , Molar , Root Canal ObturationABSTRACT
OBJECTIVE: This study aimed to evaluate the accuracy of the auto apical function in the maintenance of the apical limit of instrumentation during glide path procedures when associated to OGP kinematics of Tri Auto ZX2, compared to the continuous rotation of the same motor, as well as Root ZX II and VDW Gold. MATERIALS AND METHODS: Forty-eight extracted human mandibular single-rooted premolars were selected. After endodontic access, cervical pre-flaring was performed using size 30, 0.10 taper rotary instruments, and the apical foramen size was standardized to 200 µm. Teeth were randomly divided into four groups (n = 12) according to the device and kinematics. For all the groups, the Auto Apical Stop function (AAS) was set to the 0.0 mark. Glide path instruments size 25, .01 taper were activated inside the canals until the apical limit was reached. Then, the files were fixed with cyanoacrylate to the teeth and decoupled from the equipment. Data were statistically analyzed in GraphPad Prism 6.0 software with the significance set at 5% (Kruskal-Wallis tests). RESULTS: There was no difference in the mean deviation between the groups. No significant difference was found among the groups when the distributions and percentages of differences between the file tip and the apical foramen were compared (P > 0.05). CONCLUSION: The use of auto apical function at the 0.0 mark of all tested devices provided an adequate control of the apical limit during glide path preparation. Foramen locating accuracy of Tri Auto ZX2 in OGP kinematics was similar to those of Tri Auto ZX2, Root ZX II, and VDW Gold in continuous kinematics. CLINICAL RELEVANCE: Clinical strategies in canal negotiation and glide path as OGP motion associated to electronic foramen locators could reduce iatrogenic risk of deviation and file fractures and create an easier initial preparation to facilitate endodontic procedures.
Subject(s)
Dental Pulp Cavity , Root Canal Preparation , Biomechanical Phenomena , Electronics , Humans , Odontometry , Tooth ApexABSTRACT
Abstract This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.05 e #25/~), Reciproc Blue (RB; R25), and MTwo (M2; #10/.04, #15/.05, #20/.06 e #25/.06). The RL was defined as the apical limit, and 2.5% sodium hypochlorite irrigating solution was chosen. After the access cavity (RL 1), cervical flaring (RL 2), and complete chemical-mechanical preparation (RL 3), the RL was evaluated. The RL was evaluated by a blind examiner with the aid of a microscope (16x) placing the endodontic file stop at the coronary reference. When comparing length measurements, the RL was shorter before instrumentation than that after instrumentation. A reduction of 0.65 mm (HF), 0.61 mm (RB), and 0.48 mm (M2) was observed. However, among groups, no statistical differences were found (p > 0.05). Under the conditions tested, it can be inferred that all mechanical systems provoked RL variations, which emphasizes the need for constant verification of the odontometry, mainly before root canal obturation.
ABSTRACT
The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci's type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1). The canals were then irrigated with 2.5% sodium hypochlorite and electronically measured (EM1) employing the alginate model; all measurements were performed in triplicate by a blind operator using adjusted endodontic hand-files introduced until the apex foramen. Coronal preflaring procedures were sequentially performed with #25/.06 (conservative) and #25/.12 (conventional) instruments; new RLs extents were performed after each coronal preparation protocol (RL2/RL3), as same as electronic measurements (EM2/EM3). The devices error (mm) was evaluated considering the difference between RLs and EMs at each preparation stage; their precision was stablished adopting ±0.5 mm as tolerance margin. The EFLs error significantly reduced after conventional coronal preflaring protocol (p<0.05), which not occur after the conservative one. The best precisions values were noted after conventional preparation as 90% (Root ZX II), 97.5% (Raypex 6), and 92.5% (RomiApex A-15). No significant differences were found in EFLs comparisons, regardless of the coronal protocol tested (p>0.05). Under the conditions tested it can be concluded that the EFLs evaluated were precise. Moreover, the preflaring protocols influences its accuracy's, where the less conservative one produced the best results.
Subject(s)
Root Canal Preparation , Tooth Apex , Dental Pulp Cavity , Electronics , OdontometryABSTRACT
Abstract: The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci's type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1). The canals were then irrigated with 2.5% sodium hypochlorite and electronically measured (EM1) employing the alginate model; all measurements were performed in triplicate by a blind operator using adjusted endodontic hand-files introduced until the apex foramen. Coronal preflaring procedures were sequentially performed with #25/.06 (conservative) and #25/.12 (conventional) instruments; new RLs extents were performed after each coronal preparation protocol (RL2/RL3), as same as electronic measurements (EM2/EM3). The devices error (mm) was evaluated considering the difference between RLs and EMs at each preparation stage; their precision was stablished adopting ±0.5 mm as tolerance margin. The EFLs error significantly reduced after conventional coronal preflaring protocol (p<0.05), which not occur after the conservative one. The best precisions values were noted after conventional preparation as 90% (Root ZX II), 97.5% (Raypex 6), and 92.5% (RomiApex A-15). No significant differences were found in EFLs comparisons, regardless of the coronal protocol tested (p>0.05). Under the conditions tested it can be concluded that the EFLs evaluated were precise. Moreover, the preflaring protocols influences its accuracy's, where the less conservative one produced the best results.
Resumo O objetivo deste estudo foi avaliar a influência de diferentes protocolos de pré-alargamento cervical (ausente, conservador e convencional) na precisão dos localizadores eletrônicos foraminais (LEFs) Root ZX II, Raypex 6 e RomiApex A-15. Vinte molares inferiores com raízes mesiais do tipo IV de Vertucci foram submetidos à exploração endodôntica e confirmação da patência foraminal. Sob ampliação de 16x, seus comprimentos reais (CR) foram medidos e registrados (CR1). Os canais foram então irrigados com hipoclorito de sódio a 2,5% e medidos eletronicamente (ME1) utilizando o modelo em alginato; todas as medidas foram realizadas em triplicata por um operador cego, utilizando limas endodônticas ajustadas introduzidas até o forame apical. Os procedimentos de pré-alargamento cervical foram realizados sequencialmente com os instrumentos #25/.06 (conservador) e #25/.12 (convencional); novas determinações de CRs foram realizadas após cada protocolo de preparação cervical (CR2/CR3), da mesma forma que as medidas eletrônicas (ME2/ME3). O erro dos dispositivos (mm) foi avaliado considerando a diferença entre CRs e MEs em cada estágio de preparação; sua precisão foi estabelecida adotando ± 0,5 mm como margem de tolerância. O erro dos LEFs reduziu significativamente após o protocolo convencional de alargamento cervical (p<0,05), o que não ocorreu após o conservador. Os melhores valores de precisão foram observados após a preparação convencional como 90% (Root ZX II), 97,5% (Raypex 6) e 92,5% (RomiApex A-15). Não foram encontradas diferenças significantes nas comparações entre os LEFs, independentemente do protocolo cervical testado (p>0,05). Sob as condições testadas, pode-se concluir que os LEFs avaliados foram precisos. Além disso, os protocolos de alargamento influenciam sua precisão, onde o menos conservador produziu os melhores resultados.
Subject(s)
Root Canal Preparation , Tooth Apex , Dental Pulp Cavity , Electronics , OdontometryABSTRACT
Novas tecnologias vêm sendo incorporadas aos protocolos endodônticos com o intuito de facilitar ou tornar mais eficiente a atuação dos profissionais que os executam. Nessa perspectiva, os localizadores eletrônicos foraminais (LEFs) apresentam-se como ferramentas quase indispensáveis para uma correta determinação do comprimento real dos condutos. Por sua vez, essa etapa reveste-se de vital importância para que os procedimentos endodônticos sejam mais precisos e limitem-se às extensões desejadas pelo endodontista, sem delegá-las ao acaso ou a variações anatômicas na relação entre os forames apicais (FA) e os vértices radio- gráficos. Objetivo: O objetivo do presente artigo é discorrer sobre os protocolos de emprego dos LEFs e a influência que algumas condições clínicas podem exercer na precisão desses dispositivos. Resultados: Tomando por base a evidência científica disponível, aspectos como o ajuste do instrumento e a relação desse com o preparo cervical, o limite apical de penetração e a sequência de emprego do LEF, assim como a condição foraminal, parecem interferir significativamente nos valores de precisão observados. Conclusões: Torna-se evidente que o conhecimento do funcionamento dos localizadores e sua relação com as diversas situações clínicas per- mite utilizá-los de maneira mais efetiva, incrementando sua precisão e extraindo do equipamento, qualquer que seja, um melhor resultado, favorecendo a correta obtenção do comprimento do canal radicular, assim colaborando para a realização de uma Endodontia mais previsível e de qualidade (AU).
Novas tecnologias vêm sendo incorporadas aos protocolos endodônticos com o intuito de facilitar ou tornar mais eficiente a atuação dos profissionais que os executam. Nessa perspectiva, os localizadores eletrônicos fora- minais (LEFs) apresentam-se como ferramentas quase indis- pensáveis para uma correta determinação do comprimento real dos condutos. Por sua vez, essa etapa reveste-se de vital importância para que os procedimentos endodônticos sejam mais precisos e limitem-se às extensões desejadas pelo endodontista, sem delegá-las ao acaso ou a variações anatômicas na relação entre os forames apicais (FA) e os vértices radio- gráficos. Objetivo: O objetivo do presente artigo é discorrer sobre os protocolos de emprego dos LEFs e a influência que algumas condições clínicas podem exercer na precisão desses dispositivos. Resultados: Tomando por base a evidência científica disponível, aspectos como o ajuste do instrumento e a relação desse com o preparo cervical, o limite apical de penetração e a sequência de emprego do LEF, assim como a condição foraminal, parecem interferir significativamente nos valores de precisão observados. Conclusões: Torna-se evidente que o conhecimento do funcionamento dos localizadores e sua relação com as diversas situações clínicas per- mite utilizá-los de maneira mais efetiva, incrementando sua precisão e extraindo do equipamento, qualquer que seja, um melhor resultado, favorecendo a correta obtenção do comprimento do canal radicular, assim colaborando para a realização de uma Endodontia mais previsível e de qualidade(AU).
Subject(s)
Technology , Clinical Protocols , Electronics , Professional Training , Endodontics , Equipment and SuppliesABSTRACT
To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different working lengths (WLs): 0.0 and 1.0 mm beyond the AF. The AF of 120 root canals in 60 mesial roots of mandibular molars were photographed with stereomicroscope and randomly assigned into four groups: manual, Reciproc (REC), WaveOne (WO), and ProDesign R (PDR); subsequently, they were further subdivided according to the WL (n=15). Teeth were instrumented, coupled to a dual collecting chamber, and then another photograph of each AF was captured. Extrusion was analysed by determining the weight of extruded debris. Each AF diameter was measured in pre- and post-instrumentation images to determine deformation, which was analysed, and afterwards the final format of AFs was classified (circular/oval/deformed). We found no significant differences when analysing each system at different WLs. When considering each WL, REC and WO showed highest extrusion values (P<.05); for AF enlargement, differences were observed only for WO, when it was used beyond the AF; differences were observed among M-Wire groups beyond the AF (P<.05). AF deformation was observed in all groups; PDR showed the lowest AF deformation values at both WLs; M-Wire groups showed 50% strain beyond the AF. Authors concluded that beyond the apical limit, the alloy and taper are important aspects when considering extrusion and deformation.
Subject(s)
Nickel/chemistry , Root Canal Preparation/adverse effects , Root Canal Preparation/instrumentation , Titanium/chemistry , Tooth Apex/injuries , Dental Instruments/adverse effects , Equipment Design , Humans , Random Allocation , Reference Values , Reproducibility of Results , Root Canal Preparation/methods , Statistics, Nonparametric , Tooth Apex/anatomy & histologyABSTRACT
Abstract Objective To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different working lengths (WLs): 0.0 and 1.0 mm beyond the AF. Material and methods The AF of 120 root canals in 60 mesial roots of mandibular molars were photographed with stereomicroscope and randomly assigned into four groups: manual, Reciproc (REC), WaveOne (WO), and ProDesign R (PDR); subsequently, they were further subdivided according to the WL (n=15). Teeth were instrumented, coupled to a dual collecting chamber, and then another photograph of each AF was captured. Extrusion was analysed by determining the weight of extruded debris. Each AF diameter was measured in pre- and post-instrumentation images to determine deformation, which was analysed, and afterwards the final format of AFs was classified (circular/oval/deformed). Results We found no significant differences when analysing each system at different WLs. When considering each WL, REC and WO showed highest extrusion values (P<.05); for AF enlargement, differences were observed only for WO, when it was used beyond the AF; differences were observed among M-Wire groups beyond the AF (P<.05). AF deformation was observed in all groups; PDR showed the lowest AF deformation values at both WLs; M-Wire groups showed 50% strain beyond the AF. Conclusion Authors concluded that beyond the apical limit, the alloy and taper are important aspects when considering extrusion and deformation.
Subject(s)
Humans , Titanium/chemistry , Root Canal Preparation/adverse effects , Root Canal Preparation/instrumentation , Tooth Apex/chemistry , Nickel/chemistry , Reference Values , Random Allocation , Reproducibility of Results , Statistics, Nonparametric , Root Canal Preparation/methods , Tooth Apex/anatomy & histology , Dental Instruments/adverse effects , Equipment DesignABSTRACT
INTRODUCTION: The aim of this study was to evaluate the accuracy of 5 electronic apex locators (EALs): Root ZX II (RZX; J Morita, Tokyo, Japan), Raypex 6 (RAY; VDW GmbH, Munich, Germany), Apex ID (AID; SybronEndo, Orange, CA), Propex II (PRO; Dentsply Maillefer, Ballaigues, Switzerland), and Propex Pixi (PIXI, Dentsply Maillefer) when used in the following protocols: (1) -1.0, insertion up to 1.0 mm below the apical foramen (AF); (2) 0.0/-1.0, insertion until the AF and withdrawn 1.0 mm short of the AF; (3) 0.0, insertion until the AF; and (4) over/0.0, insertion until "over" and withdrawal to AF. METHODS: Thirty human lower premolars had coronary accesses and cervical and middle thirds preparations performed, allowing AF standardization (200 µm). Using an alginate experimental model, root canal length (RCL) measurements were performed sequentially with EALs following each of the protocols. RESULTS: Considering the suggested protocols, the lowest mean error values were observed in 0.0, 0.10 mm (RZX), 0.13 mm (RAY), 0.16 mm (AID), 0.23 mm (PRO), and 0.10 mm (PIXI), without a significant difference for over/0.0 (P > .05). Comparing the results obtained in 0.0 with those found in -1.0 and 0.0/-1.0, significant differences were observed for most EALs (P < .05). For the comparison between EALs, significant differences were observed only in protocols -1.0 and over/0.0 (P < .05). CONCLUSIONS: Under the conditions of the study, it was concluded that, regardless of the mechanism of the device, the best results were found when electronic RCL measurement was performed at the AF; furthermore, the electronic withdrawal did not offer any additional advantage over the reach of the AF.
Subject(s)
Dental Instruments , Equipment Design , Root Canal Preparation/instrumentation , Tooth Apex , Tooth Root/anatomy & histology , Bicuspid/anatomy & histology , HumansABSTRACT
OBJECTIVE: This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. MATERIAL AND METHODS: Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn's tests. For the comparison of data between groups, the Mann-Whitney test was used. RESULTS: In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.
Subject(s)
Dental Alloys/chemistry , Dental Instruments , Nickel/chemistry , Root Canal Preparation/instrumentation , Titanium/chemistry , Dental Pulp Cavity/anatomy & histology , Dentin/anatomy & histology , Equipment Design , Humans , Materials Testing , Molar , Reference Values , Reproducibility of Results , Root Canal Preparation/methods , Statistics, Nonparametric , Surface Properties , X-Ray MicrotomographyABSTRACT
Abstract Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn’s tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.
Subject(s)
Humans , Titanium/chemistry , Root Canal Preparation/instrumentation , Dental Alloys/chemistry , Dental Instruments , Nickel/chemistry , Reference Values , Surface Properties , Materials Testing , Reproducibility of Results , Statistics, Nonparametric , Root Canal Preparation/methods , Dental Pulp Cavity/anatomy & histology , Dentin/anatomy & histology , Equipment Design , X-Ray Microtomography , MolarABSTRACT
OBJECTIVES: The objective of this study was to evaluate the bond strength of three root-end filling materials (MTAA-MTA Angelus, MTAS-experimental MTA Sealer, and ZOE- zinc oxide and eugenol cement) in retrograde preparations performed with different ultrasonic tips (CVD, Trinity, and Satelec). MATERIALS AND METHOD: Ninety 2-mm root sections from single-rooted human teeth were used. The retrograde cavities were prepared by using the ultrasonic tips, coupled to a device for position standardization. The specimens were randomly divided into nine groups: CVD MTAA; CVD MTAS; CVD ZOE; Trinity MTAA; Trinity MTAS; Trinity ZOE; Satelec MTAA; Satelec MTAS; Satelec ZOE. Each resin disc/dentin/root-end filling material was placed in the machine to perform the push-out test. The specimens were examined in a stereomicroscope to evaluate the type of failure. Data were submitted to statistical analysis using ANOVA and Tukey tests (α = 0.05). RESULTS: The highest bond strength was observed for the CVD tip irrespective of the material used (P < 0.05). There was no significant difference for the Trinity TU-18 diamond and S12 Satelec tips (P > 0.05). MTAA and MTAS showed highest bond strength. The most common type of failure was adhesion between the filling material and dentin wall, except for ZOE, where mixed failure was predominant. CONCLUSIONS: The CVD tip favored higher bond strength of the root-end filling materials. MTA Angelus and experimental MTAS presented bond strength to dentin prepared with ultrasonic tips. CLINICAL RELEVANCE: Root-end preparation with the CVD tip positively influences the bond strength of root-end filling materials. MTA Angelus and experimental MTAS present bond strength to be used as root-end filling materials.
Subject(s)
Root Canal Filling Materials/chemistry , Root Canal Preparation/instrumentation , Ultrasonics/instrumentation , Bismuth , Dental Bonding , Humans , In Vitro Techniques , Materials Testing , Oxides , Silicates , Zinc Oxide-Eugenol CementABSTRACT
The present study evaluated the efficacy of electronic foramen locators (EFLs) to control root canal working length during rotary instrumentation and to assess possible reliability variations of different working lengths. Forty-eight human mandibular bicuspids were randomly divided in 2 groups according to the used device, Root ZX II (RZX) and Propex II (PRO). They were further subdivided in 2 subgroups according to the root canal preparation level (0.0 and -1.0). Preparation was performed with the Protaper rotary system using a crown-down technique. RZX was employed on its automatic auto-reverse mode (AAR) and PRO was used with the MPAS-10R contra-angle to monitor the preparation. The last used file (F3) was fixed, and the apical portion of the teeth was worn buccolingually, allowing to measure the extent between the file tip and the apical foramen (AF). The precision values of 0.0 mm and -1.0 mm were 100% and 0.0% for RZX, and 100% and 66.7% for PRO, respectively, with a range of ±0.5 mm. Statistical analysis showed no differences between the groups at 0.0 mm. However, at -1.0 mm, RZX showed the poorest results (0.96±0.11 mm), followed by PRO (0.43±0.23 mm). The difference between RZX and PRO was statistically significant. The EFLs were precise in maintaining the working length during rotary preparation when reaching the AF, but when their penetration was limited, both devices showed decreased precision; the RZX AAR failed in all instances.
Subject(s)
Dental Instruments , Dental Pulp Cavity , Tooth Apex , HumansABSTRACT
Abstract: The present study evaluated the efficacy of electronic foramen locators (EFLs) to control root canal working length during rotary instrumentation and to assess possible reliability variations of different working lengths. Forty-eight human mandibular bicuspids were randomly divided in 2 groups according to the used device, Root ZX II (RZX) and Propex II (PRO). They were further subdivided in 2 subgroups according to the root canal preparation level (0.0 and -1.0). Preparation was performed with the Protaper rotary system using a crown-down technique. RZX was employed on its automatic auto-reverse mode (AAR) and PRO was used with the MPAS-10R contra-angle to monitor the preparation. The last used file (F3) was fixed, and the apical portion of the teeth was worn buccolingually, allowing to measure the extent between the file tip and the apical foramen (AF). The precision values of 0.0 mm and -1.0 mm were 100% and 0.0% for RZX, and 100% and 66.7% for PRO, respectively, with a range of ±0.5 mm. Statistical analysis showed no differences between the groups at 0.0 mm. However, at -1.0 mm, RZX showed the poorest results (0.96±0.11 mm), followed by PRO (0.43±0.23 mm). The difference between RZX and PRO was statistically significant. The EFLs were precise in maintaining the working length during rotary preparation when reaching the AF, but when their penetration was limited, both devices showed decreased precision; the RZX AAR failed in all instances.
Resumo: O presente estudo avaliou a eficiência de localizadores eletrônicos foraminais (LEFs) em controlar o limite apical de instrumentação durante o preparo com instrumentos rotatórios. Adicionalmente, determinou-se possíveis variações quando do emprego de diferentes comprimentos de trabalho. Quarenta e oito pré-molares inferiores humanos foram randomicamente divididos em 2 grupos de acordo com o aparelho empregado, Root ZX II (RZX) e Propex II (PRO). Em seguida foram subdivididos em 2 subgrupos em função do limite de preparo (0,0 e -1,0 mm). O preparo dos canais foi realizado com o sistema Protaper em sentido coroa-ápice. O RZX foi utilizando em sua função auto-reverso automático (ARA) e o PRO associado ao contra-angulo MPAS-10R, foi empregado como ferramenta de monitoramento durante o preparo. O último instrumento utilizado (F3) foi fixado em posição, após o que a porção apical dos dentes foi desgastada permitindo a determinação da distância entre a ponta dos instrumentos e o forame apical (FA). A precisão a 0,0 mm e -1,0 mm foi de 100% e 0,0% para o RZX, e de 100% e 66,7% para o PRO, respectivamente, considerando uma margem de ±0,05 mm. A análise estatística não encontrou diferenças entre os grupos a 0,0 mm, todavia, a -1,0 mm, o RZX ofereceu os piores resultados (0,96±0,11 mm), seguido do PRO (0,43±0,23 mm). Esta diferença foi estatisticamente significante. Os LEFs foram precisos na manutenção do comprimento de trabalho durante o preparo rotatório quando se atingiu o FA, todavia, quando esta penetração foi limitada, ambos os aparelhos perderam em precisão; o sistema ARA do RZX falhou em todos os casos.
Subject(s)
Humans , Dental Instruments , Dental Pulp Cavity , Tooth ApexABSTRACT
To compare the time dispensed and the surface characteristics when a root-end resection was performed with a surgical ultrasonic device (VarioSurg, NSK, Japan) or with a Zekrya bur. Forty distal roots of freshly extracted mandibular molars were selected and divided into four different groups: (G1) stainless steel insert with ultrasound; (G2) diamond insert with ultrasound; (G3) stainless steel and diamond inserts with ultrasound, and (G4) Zekrya burs. The time required for the root-end resection was timed and the surface characteristics were evaluated via scanning electronic microscopy. The median times for the root-end resections were: 115.9 s for G1, 249.8 s for G2, 112.7 s for G3, and 7.44 s for G4, the latter presented a smoother root-end surface. There was no statistically significant difference in the comparisons between G3 group and G4 group (Zekrya burs). The other groups where the root-end resections were with ultrasonic devices proportioned a prolonged time to resection with irregular surfaces.
Subject(s)
Apicoectomy/methods , Microscopy, Electron, Scanning , Surface Properties , Tooth Apex/diagnostic imaging , Tooth Apex/surgery , Molar/diagnostic imaging , Molar/surgery , Time , UltrasonographyABSTRACT
Novos recursos tecnológicos foram introduzidos na Odontologia e, em especial, na Endodontia, com o objetivo de torná-la mais previsível e de alcance a maior número de profissionais. A radiografia digital, tomografia, instrumentos oscilatórios e reciprocantes, ativação da solução irrigadora por meio do ultrassom, técnicas termoplastificadoras de obturação dos canais e o uso do MTA e do microscópio cirúrgico permitem que, casos considerados difíceis, tornem-se mais viáveis de tratamento. Todavia, é importante que o profissional, além do domínio da tecnologia, tenha embasamento científico adequado para utilizar esses recursos. Neste artigo feita uma análise das diferentes tecnologias introduzidas na Endodontia
New technologies have been developed in Dentistry especially in Endodontics so that it could be a more predictable treatment as well as accessible to a large number of professionals. Technologies such as digital radiography, CT, rotary and reciprocating files, passive and constant ultrasonic irrigation, thermo-plasticized root canal filling materials, and MTA and surgical microscopes, have become viable for daily use in endodontic treatment and are an important aid in cases that were previously considered as complicated. However, it is important that the professional have proper scientific basis and knowledge of such technologies. The present paper presets an analysis of some of the technologies recently introduced in endodontics
Subject(s)
Dental Instruments , Root Canal Therapy , Technology, Dental/methods , Radiographic Image Enhancement/methods , Microscopy, Electron, Scanning/methodsABSTRACT
BACKGROUND: Owing to a lack of symptoms and difficult visualization in routine intraoral radiographs, diagnosis of external root resorptions can be challenging. AIM: The goal of this study was to compare two image acquisition methods, intraoral radiographs and cone beam computed tomography (CBCT), in the diagnosis of external resorption. MATERIAL AND METHODS: Thirty-four maxillary and mandibular bicuspids were divided into three groups. Perforations measuring 0.3 and 0.6 mm in diameter and 0.15 and 0.3 mm in depth, respectively, were made on the lingual root surfaces in thirty teeth, and four were used as controls. Next, teeth were mounted on an apparatus and radiographed at mesial, distal, and orthoradial angulations. CBCT images were also taken. The analysis of the intraoral radiographic and tomographic images was carried out by two experts using standardized scores. Data were then compared statistically. RESULTS: A strong agreement between the examiners was observed in both diagnosis methods, the intraoral radiographic (r = 0.93) and the tomographic analysis (r = 1.0). Tomography had higher statistically significant detection values than intraoral radiography (P < 0.05). In intraoral radiographs, the detection was significantly greater (P < 0.05) in the mandibular bicuspids, compared with their maxillary counterparts. The ability to detect 0.6-mm perforations by intraoral radiography was significantly higher than that of 0.3-mm perforations (P < 0.05). CONCLUSION: Cone beam computed tomography showed better diagnostic ability compared with intraoral radiography, regardless of the tooth or the dimensions of the resorption evaluated.
Subject(s)
Cone-Beam Computed Tomography/statistics & numerical data , Radiography, Dental/statistics & numerical data , Root Resorption/diagnostic imaging , Tooth Root/diagnostic imaging , Bicuspid/diagnostic imaging , Cone-Beam Computed Tomography/methods , Humans , Incisor/diagnostic imaging , Jaw/diagnostic imaging , Radiography, Dental/methodsABSTRACT
OBJECTIVES: To evaluate the sealing ability of five root canal sealers, including two experimental cements (MBP and MTA-Obtura) using the fluid filtration method. MATERIAL AND METHODS: Teeth were divided into 5 study groups: G1-AH Plus; G2-Acroseal; G3Sealapex; G4-MBP; G5-MTA-Obtura; and two controls. Chemical-mechanical preparation was performed with ProFile rotary nickel-titanium instruments 1 mm short of the apical foramen. The sealing ability was evaluated by fluid filtration at 15, 30, and 60 days. RESULTS: The statistical analysis showed significant difference between the materials at different periods (p<0.05). AH Plus and MBP had similar leakage values at 15 and 60 days, alternating with significant reduction at 30 days, while the other materials showed progressive increase in leakage values. Acroseal and Sealapex presented the best results at 15 days and the worst at 60 days. CONCLUSIONS: All sealers evaluated presented fluid leakage, with AH Plus and MBP showing the best results at the end of the experimental period. Acroseal, Sealapex, and MTA-Obtura presented increase in leakage values at longer observation periods.
Subject(s)
Humans , Dental Leakage , In Vitro Techniques , Root Canal Filling Materials/chemistry , Root Canal Obturation/methods , Aluminum Compounds/chemistry , Calcium Compounds/chemistry , Calcium Hydroxide/chemistry , Drug Combinations , Gutta-Percha/chemistry , Materials Testing , Oxides/chemistry , Resin Cements/chemistry , Statistics, Nonparametric , Salicylates/chemistry , Silicates/chemistry , Time FactorsABSTRACT
OBJECTIVES: To evaluate the sealing ability of five root canal sealers, including two experimental cements (MBP and MTA-Obtura) using the fluid filtration method. MATERIAL AND METHODS: Teeth were divided into 5 study groups: G1-AH Plus; G2-Acroseal; G3Sealapex; G4-MBP; G5-MTA-Obtura; and two controls. Chemical-mechanical preparation was performed with ProFile rotary nickel-titanium instruments 1 mm short of the apical foramen. The sealing ability was evaluated by fluid filtration at 15, 30, and 60 days. RESULTS: The statistical analysis showed significant difference between the materials at different periods (p<0.05). AH Plus and MBP had similar leakage values at 15 and 60 days, alternating with significant reduction at 30 days, while the other materials showed progressive increase in leakage values. Acroseal and Sealapex presented the best results at 15 days and the worst at 60 days. CONCLUSIONS: All sealers evaluated presented fluid leakage, with AH Plus and MBP showing the best results at the end of the experimental period. Acroseal, Sealapex, and MTA-Obtura presented increase in leakage values at longer observation periods.
Subject(s)
Dental Leakage , Root Canal Filling Materials/chemistry , Root Canal Obturation/methods , Aluminum Compounds/chemistry , Calcium Compounds/chemistry , Calcium Hydroxide/chemistry , Drug Combinations , Gutta-Percha/chemistry , Humans , In Vitro Techniques , Materials Testing , Oxides/chemistry , Resin Cements/chemistry , Salicylates/chemistry , Silicates/chemistry , Statistics, Nonparametric , Time FactorsABSTRACT
This study evaluated the increase of the instrumented area and dentin thickness in the mesial and distal aspects of mesial canals of mandibular molars after the use of Gates Glidden (GG), LA Axxess (LA) and Orifice Shaper (OS) instruments. A total of 53 canals from 27 mandibular molars were embedded in resin and divided into 3 groups. The roots were sectioned 3 mm below the cementoenamel junction and the images were captured before and after instrumentation. The increase of the instrumented area in terms of percentages and the remaining dentin thickness, in mm, at the mesial and furcal aspects were calculated using the Image tools software. Data were analyzed using the Kruskal-Wallis and Dunn's test. The significance level was set at 5%. All instruments promoted cervical flaring with different amounts of dentin removal at the mesial and distal aspects of the root canals. Statistically significant difference (p<0.05) was found between LA and all other instruments after using the first instrument. Regarding dentin thickness, no significant difference (p>0.05) was found between the mesial and distal walls in all groups. It may be concluded that LA 35.06 and GG 3 burs produced the thinnest dentin walls, and thus their use in mesial canals of mandibular molars should be done with caution.