Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Neurointervention ; 17(2): 106-109, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35385899

ABSTRACT

The Woven EndoBridge (WEB; MicroVention, Aliso Viejo, CA, USA) intrasaccular flow disruptor is a therapeutic option for wide neck bifurcation intracranial aneurysms that does not require the use of adjunctive techniques such as stents or balloon remodeling. As with other endovascular devices, displacement of the WEB is a recognized complication. Few reports have been published regarding the management of this type of complication. We describe a case of retrieval of a displaced WEB using a Solitaire Platinum revascularization device (Medtronic, Minneapolis, MN, USA). Interventionists should be aware of this option in the management of such a complication.

2.
Neurointervention ; 17(1): 28-36, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35130672

ABSTRACT

PURPOSE: Advances in endovascular technology have expanded the treatment options for intracranial aneurysms. Intrasaccular flow diversion is a relatively new technique that aims to disrupt blood inflow at the neck of the aneurysm, hence promoting intrasaccular thrombosis. The Woven EndoBridge device (WEB; MicroVention, Aliso Viejo, CA, USA) is an US Food and Drug Administration approved intrasaccular flow diverter for wide-necked aneurysms. We report the early interim clinical and radiological outcomes of patients with both ruptured and unruptured intracranial aneurysms (IAs) treated using the WEB device in an Australian population. MATERIALS AND METHODS: A retrospective analysis was done of patients with ruptured or unruptured IAs who received treatment with WEB across 5 Australian neuroendovascular referral centers between May 2017 and November 2020. Angiographic occlusion was assessed with time-of-flight magnetic resonance angiography. Complications were recorded and clinical outcomes were assessed using the modified Rankin scale at follow-up. RESULTS: In total, 66 aneurysms were treated in 63 patients, with successful deployment of the WEB device in 98.5% (n=65). Eighteen (26.9%) ruptured aneurysms were included. Failure of deployment occurred in a single case. Adjunct coiling and/or stenting was performed in 20.9% (n=14) cases. Sixty-two patients with 65 aneurysms using a WEB device were followed up (mean=9.1 months), and 89.4% of these had complete aneurysm occlusion while 1.5% remained patent. Functional independence was achieved in 93.5% of cases. CONCLUSION: Early results following the use of WEB devices in Australia demonstrate safety and adequate aneurysm occlusion comparable to international literature.

3.
J Neurointerv Surg ; 12(11): 1053-1057, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32680876

ABSTRACT

BACKGROUND: Operating rooms contribute between 20% to 70% of hospital waste. This study aimed to evaluate the waste burden of neurointerventional procedures performed in a radiology department, identify areas for waste reduction, and motivate new greening initiatives. METHODS: We performed a waste audit of 17 neurointerventional procedures at a tertiary-referral center over a 3-month period. Waste was categorized into five streams: general waste, clinical waste, recyclable plastic, recyclable paper, and sharps. Our radiology department started recycling soft plastics from 13 December 2019. Hence, an additional recyclable soft plastic waste stream was added from this time point. The weight of each waste stream was measured using a digital weighing scale. RESULTS: We measured the waste from seven cerebral digital subtraction angiograms (DSA), six mechanical thrombectomies (MT), two aneurysm-coiling procedures, one coiling with tumour embolization, and one dural arteriovenous fistula embolization procedure. In total, the 17 procedures generated 135.3 kg of waste: 85.5 kg (63.2%) clinical waste, 28.0 kg (20.7%) general waste, 14.7 kg (10.9%) recyclable paper, 3.5 kg (2.6%) recyclable plastic, 2.2 kg (1.6%) recyclable soft plastic, and 1.4 kg (1.0%) of sharps. An average of 8 kg of waste was generated per case. Coiling cases produced the greatest waste burden (13.1 kg), followed by embolization (10.3 kg), MT (8.8 kg), and DSA procedures (5.1 kg). CONCLUSION: Neurointerventional procedures generate a substantial amount of waste, an average of 8 kg per case. Targeted initiatives such as engaging with suppliers to revise procedure packs and reduce packaging, digitizing paper instructions, opening devices only when necessary, implementing additional recycling programs, and appropriate waste segregation have the potential to reduce the environmental impact of our specialty.


Subject(s)
Anesthesia, Conduction/statistics & numerical data , Medical Waste/statistics & numerical data , Angiography, Digital Subtraction/statistics & numerical data , Australia , Cerebral Angiography/statistics & numerical data , Drug Packaging/statistics & numerical data , Embolization, Therapeutic/statistics & numerical data , Humans , Management Audit , Medical Waste/prevention & control , Operating Rooms , Paper , Plastics , Recycling , Tertiary Care Centers
SELECTION OF CITATIONS
SEARCH DETAIL
...