Clin Infect Dis ; 75(7): 1217-1223, 2022 09 30.
Article in English | MEDLINE | ID: mdl-35100614

ABSTRACT

BACKGROUND: Multidrug-resistant organisms (MDROs) frequently contaminate hospital environments. We performed a multicenter, cluster-randomized, crossover trial of 2 methods for monitoring of terminal cleaning effectiveness. METHODS: Six intensive care units (ICUs) at 3 medical centers received both interventions sequentially, in randomized order. Ten surfaces were surveyed each in 5 rooms weekly, after terminal cleaning, with adenosine triphosphate (ATP) monitoring or an ultraviolet fluorescent marker (UV/F). Results were delivered to environmental services staff in real time with failing surfaces recleaned. We measured monthly rates of MDRO infection or colonization, including methicillin-resistant Staphylococcus aureus, Clostridioides difficile, vancomycin-resistant Enterococcus, and MDR gram-negative bacilli (MDR-GNB) during a 12-month baseline period and sequential 6-month intervention periods, separated by a 2-month washout. Primary analysis compared only the randomized intervention periods, whereas secondary analysis included the baseline. RESULTS: The ATP method was associated with a reduction in incidence rate of MDRO infection or colonization compared with the UV/F period (incidence rate ratio [IRR] 0.876; 95% confidence interval [CI], 0.807-0.951; P = .002). Including the baseline period, the ATP method was associated with reduced infection with MDROs (IRR 0.924; 95% CI, 0.855-0.998; P = .04), and MDR-GNB infection or colonization (IRR 0.856; 95% CI, 0.825-0.887; P < .001). The UV/F intervention was not associated with a statistically significant impact on these outcomes. Room turnaround time increased by a median of 1 minute with the ATP intervention and 4.5 minutes with UV/F compared with baseline. CONCLUSIONS: Intensive monitoring of ICU terminal room cleaning with an ATP modality is associated with a reduction of MDRO infection and colonization.


Subject(s)
Cross Infection , Methicillin-Resistant Staphylococcus aureus , Vancomycin-Resistant Enterococci , Adenosine Triphosphate , Cross Infection/epidemiology , Cross Infection/prevention & control , Drug Resistance, Multiple, Bacterial , Gram-Negative Bacteria , Humans , Intensive Care Units , Vancomycin
SELECTION OF CITATIONS
SEARCH DETAIL