Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Monit Assess ; 196(8): 718, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980522

ABSTRACT

In Burkina Faso, several investigations have raised suspicions that hospital liquid effluents are the source of contaminants in porbeagle-culture products and surface water in urban and peri-urban areas. This study aimed to evaluate the hygienic quality of hospital liquid effluents discharged into nature by the UHC Bogodogo (UHC-BOG), Yalgado Ouédraogo (UHC-YO), and the WWTS of Kossodo (WWTS-KOS). Thus, 15 samples of liquid effluents (five per site) discharged into nature were collected. Within the physicochemical parameters, the pH, chemical oxygen demand (COD), biochemical oxygen demand (BOD5), suspended solids (TSS), conductivity, copper, iron, hafnium, silver, mercury, lead, and cadmium of these samples were determined using standard methods. The mean values of pH were 8.84 ± 0.42,8.06 ± 0.54, and 8.55 ± 0.53 for WWTS-KOS, UHC-BOG, and UHC-YO, respectively. Conductivity values were 1956.80 ± 81.30, 812.80 ± 45.22, and 956.00 ± 39.96 µS/cm, respectively. TSS were 338.20 ± 38.80, 45.00 ± 5.79, and 187.80 ± 27.58 mg/L, respectively. COD were 274.80 ± 20.46, 35.00 ± 5.52, and 139.80 ± 25.53 mg/L, respectively. BOD5 were 186.40 ± 68.68, 26.20 ± 4.82, and 81.80 ± 15.63 mg/L, respectively. Mercury values were 1.93 ± 0.38, 4.04 ± 0.38, and 14.37 ± 1.65 µg/L, respectively. Lead values were 434.70 ± 202.42, 310.50 ± 4.09, and 367.43 ± 94.01 µg/L, respectively. Cadmium values were 79.59 ± 19.48, 109.94 ± 8.43, and 80.26 ± 7.85 µg/L, respectively. Copper values were 27.66 ± 3.33, 30.84 ± 1.65, and 28.32 ± 2.36 mg/L, respectively. Iron was detected only on the STEP-KOS with an average of 71.01 ± 37.83 mg/L. Hafnium values were 50.27 ± 4.49 and 51.58 ± 4.61 mg/L for WWTS-KOS and UHC-BOG, respectively. Silver values were 34.26 ± 3.06 for WWTS-KOS. On the three sites, the differences found were significant (p < 0.05). Liquid hospital effluents from Ouagadougou discharged into nature on the whole do not compile with the Burkinabè normative values for the discharge of wastewater into the environment.


Subject(s)
Environmental Monitoring , Waste Disposal, Fluid , Wastewater , Water Pollutants, Chemical , Burkina Faso , Wastewater/chemistry , Water Pollutants, Chemical/analysis , Hospitals, University , Biological Oxygen Demand Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...