Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
BMC Anesthesiol ; 24(1): 117, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38532344

ABSTRACT

BACKGROUND: Abnormal diastolic function is an independent predictor of adverse postoperative outcomes. Mitral annular tissue Doppler velocity (e') is a key parameter for assessing diastolic function. The purpose of this study was to confirm that an acute increase in preload did not significantly impact the intraoperative measurement of e' and secondarily evaluate the impact of this acute intravascular volume increase on the clinical assessment of diastolic function using a previously described simplified algorithm. METHODS: This was a prospective, non-randomized study in adult patients undergoing elective cardiac surgeries requiring transesophageal echocardiographic monitoring, arterial pressure and Swan-Ganz catheter placements as part of the surgical procedure. Following baseline echocardiographic and hemodynamic measurements, 500 ml of crystalloid solution was infused over 10 min. Hemodynamic and echocardiographic measurements were repeated 5 min after fluid administration. RESULTS: Complete data sets were available from 84 of the 100 patients who were enrolled in this study. There was no significant change in the values of e'. The average baseline was 7.8 ± 2.0 cm/s (95%CI: 7.4, 8.2) and 8.1 ± 2.4 (95%CI: 7.6, 8.6) following the fluid bolus (p = 0.10). All hemodynamic variables associated with increased intravascular volume (central venous pressure, pulmonary arterial pressures and stroke volume variation) changed significantly. The overall distribution of diastolic function grades did not change following fluid administration (p = 0.69). However, there were many individual patient differences. When using this simplified algorithm, functional grading changed in 35 patients. Thirty of these 35 changes were only a single grade shift. 22 patients had worse functional grading after fluid administration while 13 had improved grading. Nine patients with normal diastolic function at baseline demonstrated diastolic dysfunction after fluid administration while 6 patients with baseline dysfunction normalized following the fluid bolus. CONCLUSION: We confirmed that e' is a robust measurement that is reproducible in the intraoperative setting despite variable vascular volume loading conditions, however, the clinical assessment of diastolic function was still altered in 42% of the patients following an intravenous fluid bolus.


Subject(s)
Mitral Valve , Ventricular Dysfunction, Left , Adult , Humans , Prospective Studies , Diastole , Hemodynamics , Echocardiography
3.
J Cardiothorac Vasc Anesth ; 36(1): 22-29, 2022 01.
Article in English | MEDLINE | ID: mdl-34059438

ABSTRACT

Diagnostic point-of-care ultrasound (PoCUS) has emerged as a powerful tool to help anesthesiologists guide patient care in both the perioperative setting and the subspecialty arenas. Although anesthesiologists can turn to guideline statements pertaining to other aspects of ultrasound use, to date there remains little in the way of published guidance regarding diagnostic PoCUS. To this end, in 2018, the American Society of Anesthesiologists chartered an ad hoc committee consisting of 23 American Society of Anesthesiologists members to provide recommendations on this topic. The ad hoc committee convened and developed a committee work product. This work product was updated in 2021 by an expert panel of the ad hoc committee to produce the document presented herein. The document, which represents the consensus opinion of a group of practicing anesthesiologists with established expertise in diagnostic ultrasound, addresses the following issues: (1) affirms the practice of diagnostic PoCUS by adequately trained anesthesiologists, (2) identifies the scope of practice of diagnostic PoCUS relevant to anesthesiologists, (3) suggests the minimum level of training needed to achieve competence, (4) provides recommendations for how diagnostic PoCUS can be used safely and ethically, and (5) provides broad guidance about diagnostic ultrasound billing.


Subject(s)
Point-of-Care Systems , Point-of-Care Testing , Anesthesiologists , Humans , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL