Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Catheter Cardiovasc Interv ; 102(6): 1140-1148, 2023 11.
Article in English | MEDLINE | ID: mdl-37668110

ABSTRACT

BACKGROUND: Preprocedural computed tomography planning improves procedural safety and efficacy of transcatheter aortic valve implantation (TAVI). However, contemporary imaging modalities do not account for device-host interactions. AIMS: This study evaluates the value of preprocedural computer simulation with FEops HEARTguideTM on overall device success in patients with challenging anatomies undergoing TAVI with a contemporary self-expanding supra-annular transcatheter heart valve. METHODS: This prospective multicenter observational study included patients with a challenging anatomy defined as bicuspid aortic valve, small annulus or severely calcified aortic valve. We compared the heart team's transcatheter heart valve (THV) planning decision based on (1) conventional multislice computed tomography (MSCT) and (2) MSCT imaging with FEops HEARTguideTM simulations. Clinical outcomes and THV performance were followed up to 30 days. RESULTS: A total of 77 patients were included (median age 79.9 years (IQR 74.2-83.8), 42% male). In 35% of the patients, preprocedural planning changed after FEops HEARTguideTM simulations (change in valve size selection [12%] or target implantation height [23%]). A new permanent pacemaker implantation (PPI) was implanted in 13% and >trace paravalvular leakage (PVL) occurred in 28.5%. The contact pressure index (i.e., simulation output indicating the risk of conduction abnormalities) was significantly higher in patients with a new PPI, compared to those without (16.0% [25th-75th percentile 12.0-21.0] vs. 3.5% [25th-75th percentile 0-11.3], p < 0.01) The predicted PVL was 5.7 mL/s (25th-75th percentile 1.3-11.1) in patients with none-trace PVL, 12.7 (25th-75th percentile 5.5-19.1) in mild PVL and 17.7 (25th-75th percentile 3.6-19.4) in moderate PVL (p = 0.04). CONCLUSION: FEops HEARTguideTM simulations may provide enhanced insights in the risk for PVL or PPI after TAVI with a self-expanding supra-annular THV in complex anatomies.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Female , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Computer Simulation , Prospective Studies , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Multidetector Computed Tomography/methods , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...