1.
Ultrasound Int Open ; 2(2): E63-7, 2016 May.
Article in English | MEDLINE | ID: mdl-27689173

ABSTRACT

PURPOSE: The goal of this study was to objectively quantify cervical stiffness in misoprostol users prior to IUC insertion and at follow-up consultation to evaluate the feasibility of assessing cervical stiffness and to study the influence of misoprostol on cervical softening. MATERIALS AND METHODS: This was a cross-sectional study that evaluated 40 women who wished to use the LNG IUS. These women were evaluated immediately before LNG IUS insertion and 6 weeks later at follow-up consultation. Participants received 200 µg of misoprostol combined with 75 mg of diclofenac in a single tablet orally (Arthrotec forte 75/200(®), Pfizer, USA) 6-12 h prior to insertion in "off label" use. On both occasions, cervical stiffness was determined using a novel medical device based on the aspiration technique. The Wilcoxon rank-sum and the Wilcoxon signed-rank test were applied to compare cervical stiffness assessments at insertion of the IUD and at follow-up. RESULTS: For the first time, cervical stiffness was quantitatively assessed in misoprostol users prior to IUD insertion, proving that the aspiration technique enables detection of pharmacologically induced cervical changes, and also that misoprostol has a detectable softening effect on cervical tissue. CONCLUSION: The clinical value of the detected cervical softening after misoprostol administration remains unclear. Aspiration measurements could be helpful in searching for the ideal candidate, the appropriate route, dosage and interval of misoprostol intake prior to IUC insertion.

2.
J Biomech ; 48(9): 1541-8, 2015 Jun 25.
Article in English | MEDLINE | ID: mdl-25791058

ABSTRACT

Measuring the stiffness of the uterine cervix might be useful in the prediction of preterm delivery, a still unsolved health issue of global dimensions. Recently, a number of clinical studies have addressed this topic, proposing quantitative methods for the assessment of the mechanical properties of the cervix. Quasi-static elastography, maximum compressibility using ultrasound and aspiration tests have been applied for this purpose. The results obtained with the different methods seem to provide contradictory information about the physiologic development of cervical stiffness during pregnancy. Simulations and experiments were performed in order to rationalize the findings obtained with ultrasound based, quasi-static procedures. The experimental and computational results clearly illustrate that standardization of quasi-static elastography leads to repeatable strain values, but for different loading forces. Since force cannot be controlled, this current approach does not allow the distinction between a globally soft and stiff cervix. It is further shown that introducing a reference elastomer into the elastography measurement might overcome the problem of force standardization, but a careful mechanical analysis is required to obtain reliable stiffness values for cervical tissue. In contrast, the maximum compressibility procedure leads to a repeatable, semi-quantitative assessment of cervical consistency, due to the nonlinear nature of the mechanical behavior of cervical tissue. The evolution of cervical stiffness in pregnancy obtained with this procedure is in line with data from aspiration tests.


Subject(s)
Cervix Uteri/physiology , Biomechanical Phenomena , Cervix Uteri/diagnostic imaging , Elasticity Imaging Techniques , Female , Finite Element Analysis , Humans , Models, Biological , Phantoms, Imaging , Pregnancy