Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Drug Res (Stuttg) ; 73(6): 349-354, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37094796

ABSTRACT

Favipiravir is an antiviral drug used to treat influenza and is also being investigated for the treatment of SARS-CoV-2. Its pharmacokinetic profile varies depending on ethnic group. The present research examines the pharmacokinetic features of favipiravir in healthy male Egyptian volunteers. Another goal of this research is to determine the optimum dissolution testing conditions for immediate release tablets. In vitro dissolution testing was investigated for favipiravir tablets in three different pH media. The pharmacokinetic features of favipiravir were examined in 27 healthy male Egyptian volunteers. The parameter "AUC0-t" vs. percent dissolved was used to develop level C in vitro in vivo correlation (IVIVC) to set the optimum dissolution medium to achieve accurate dissolution profile for favipiravir (IR) tablets. The in vitro release results revealed significant difference among the three different dissolution media. The Pk parameters of twenty-seven human subjects showed mean value of Cpmax of 5966.45 ng/mL at median tmax of 0.75 h with AUC0-∞ equals 13325.54 ng.h/mL, showing half-life of 1.25 h. Level C IVIVC was developed successfully. It was concluded that Egyptian volunteers had comparable Pk values to American and Caucasian volunteers, however they were considerably different from Japanese subjects. AUC0-t vs. % dissolved was used to develop level C IVIVC to set the optimum dissolution medium. Phosphate buffer medium (pH 6.8) was found to be the optimum dissolution medium for in vitro dissolution testing for Favipiravir IR tablets.


Subject(s)
COVID-19 , Humans , Male , Egypt , Area Under Curve , SARS-CoV-2 , Tablets , Volunteers , Solubility , Healthy Volunteers
2.
Biomed Chromatogr ; 35(7): e5098, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33606892

ABSTRACT

A novel, simple and rapid UPLC-MS/MS method was developed and validated for determination of favipiravir (FAV) in human plasma. Lamivudine was used as an internal standard (IS). The Xevo TQD LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. Precipitation with acetonitrile was used in sample preparation as it gives relatively cleaner plasma samples. The prepared samples were chromatographed using an Acquity UPLC® HSS C18 (100 × 2.1 mm, 1.8 µm) column. The mobile phase was composed of ammonium formate and methanol in a gradient mode that was pumped at a flow rate of 0.35 ml/min. The developed method was validated as per the FDA guidelines and linearity was in the range of 0.25-16 µg/ml for FAV. The intra- and inter-day precision and accuracy results were within the acceptable limits. A run time of 4.5 min and a low quantification limit of FAV allowed the application of the developed method for the determination of FAV in a bioequivalence study in healthy human volunteers.


Subject(s)
Amides/blood , Chromatography, High Pressure Liquid/methods , Pyrazines/blood , Tandem Mass Spectrometry/methods , Adult , Amides/chemistry , Amides/pharmacokinetics , Female , Humans , Limit of Detection , Male , Middle Aged , Pyrazines/chemistry , Pyrazines/pharmacokinetics , Reproducibility of Results , Therapeutic Equivalency , Young Adult
3.
Biomed Chromatogr ; 35(5): e5048, 2021 May.
Article in English | MEDLINE | ID: mdl-33314205

ABSTRACT

A robust and rapid UPLC-MS/MS method has been developed, optimized and validated for determination of amlodipine (AML), indapamide (IND) and perindopril (PRN) in human plasma. A positive electrospray ionization mode was used in a Xevo TQD LC-MS/MS instrument. A single sample preparation step using extraction technique was applied to extract the three analytes from plasma samples. There was no need to extract indapamide from blood samples in a further step. Extraction of the three drugs and internal standards was done using a solvent mixture composed of methyl tertiary butyl ether, dichloromethane and ethyl acetate. The prepared samples were analyzed using an Acquity UPLC HSS C18 (100 × 2.1 mm, 1.7 µm) column. Ammonium acetate and methanol, pumped at a flow rate of 0.3 ml/min, were used as a mobile phase. Method validation was done as per the US Food and Drug Administration guidelines. Linearity was achieved in the range of 0.2-15 ng/ml for AML, 0.5-50 ng/ml for IND and 0.5-120 ng/ml for PRN. Accuracy and precision were estimated and found to be within the acceptable ranges. The rapid chromatography permits analysis of many samples per batch, making the method suitable for clinical and pharmacokinetic investigations. The developed and validated method was applied to estimate AML, IND, and PRN in a fasting bioequivalence study in healthy human volunteers.


Subject(s)
Amlodipine , Antihypertensive Agents , Chromatography, High Pressure Liquid/methods , Indapamide , Perindopril , Tandem Mass Spectrometry/methods , Adult , Amlodipine/blood , Amlodipine/pharmacokinetics , Antihypertensive Agents/blood , Antihypertensive Agents/pharmacokinetics , Humans , Indapamide/blood , Indapamide/pharmacokinetics , Limit of Detection , Middle Aged , Perindopril/blood , Perindopril/pharmacokinetics , Specimen Handling , Therapeutic Equivalency
4.
Biomed Chromatogr ; 32(11): e4347, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30047564

ABSTRACT

A novel and sensitive LC-MS/MS method was developed, optimized and validated for quantification of sofosbuvir (SOF) and velpatasvir (VEL) in human plasma using ledipasvir as an internal standard (IS). Sample preparation was done using acetonitrile for precipitation of plasma proteins. Chromatographic analysis was done on an Acquity UPLC BEH C18 column using 0.1% formic acid and acetonitrile as a mobile phase. The Xevo TQD LC-MS/MS system was run with electrospray ionization mode. The developed method was optimized and then validated according to the US Food and Drug Administration guidelines. Linearity was found to be in the range of 0.25-3500 ng/mL for SOF and 1-1000 ng/mL for VEL. A short run time of 1.5 min allows swift analysis of many plasma samples per day. The developed method was successfully utilized for estimating both SOF and VEL in the plasma of healthy human volunteers participated in a bioequivalence study.


Subject(s)
Carbamates/blood , Chromatography, High Pressure Liquid/methods , Heterocyclic Compounds, 4 or More Rings/blood , Sofosbuvir/blood , Tandem Mass Spectrometry/methods , Adult , Carbamates/pharmacokinetics , Female , Heterocyclic Compounds, 4 or More Rings/pharmacokinetics , Humans , Linear Models , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Sofosbuvir/pharmacokinetics , Therapeutic Equivalency , Young Adult
5.
Biomed Chromatogr ; 32(7): e4224, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29498757

ABSTRACT

A robust, rapid and sensitive UPLC-MS/MS method has been developed, optimized and validated for the determination of amlodipine (AML) and atorvastatin (ATO) in human plasma using eplerenone as an internal standard (IS). Multiple-reaction monitoring in positive electrospray ionization mode was utilized in Xevo TQD LC-MS/MS. Double extraction was used in sample preparation using diethyl ether and ethyl acetate. The prepared samples were analyzed using an Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 µm) column. Ammonium formate and acetonitrile, pumped isocraticaly at a flow rate of 0.25 mL/min, were used as a mobile phase. Method validation was done as per the US Food and Drug Administration guidelines. Linearity was achieved in the range of 0.1-10 ng/mL for AML and 0.05-50 ng/mL for ATO. Intra-day and inter-day accuracy and precision were calculated and found to be within the acceptable range. A short run time, of <1.5 min, permits analysis of a large number of plasma samples per batch. The developed and validated method was applied to estimate AML and ATO in a bioequivalence study in healthy human volunteers.


Subject(s)
Amlodipine/blood , Atorvastatin/blood , Chromatography, High Pressure Liquid/methods , Tandem Mass Spectrometry/methods , Adolescent , Adult , Amlodipine/chemistry , Amlodipine/pharmacokinetics , Atorvastatin/chemistry , Atorvastatin/pharmacokinetics , Humans , Linear Models , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Therapeutic Equivalency , Young Adult
6.
Clin Drug Investig ; 38(5): 439-448, 2018 May.
Article in English | MEDLINE | ID: mdl-29417463

ABSTRACT

BACKGROUND AND OBJECTIVES: The purpose of this study was to apply the reference-scaled average bioequivalence (RSABE) approach to evaluate the bioequivalence and to investigate the pharmacokinetic properties of two formulations of fixed dose combination (FDC) tablet of sofosbuvir (SOF) and ledipasvir (LED) (400/90 mg) in 36 healthy Egyptian volunteers. METHODS: The study was performed in single-dose, randomized-sequence, open-label, reference-replicated, 3-period crossover design (RTR, TRR, RRT), with a washout period of 2 weeks. A rapid and simple LC-MS/MS method was developed and validated for the simultaneous estimation of SOF and LED using eplerenone as an internal standard (IS). RESULTS: The results showed that the 90% confidence intervals (CIs) for natural log-transformed ratios of Cmax, AUClast and AUC∞ of SOF (89.95-115.31, 98.77-109.75 and 98.79-109.75) were within the RSABE acceptance limits. The 90% CIs for natural log-transformed ratios of Cmax and AUClast of LED (87.33-115.15 and 83.82-112.26) were within the FDA bioequivalence limits (80.00-125.00). In addition, the in vitro dissolution study was done and both formulations released > 85% of drug within 15 min in the proposed dissolution medium. CONCLUSIONS: In conclusion, bioequivalence between the two fixed-dose combination products was demonstrated for both active ingredients.


Subject(s)
Benzimidazoles/administration & dosage , Benzimidazoles/pharmacokinetics , Drugs, Generic/administration & dosage , Drugs, Generic/pharmacokinetics , Fluorenes/administration & dosage , Fluorenes/pharmacokinetics , Sofosbuvir/administration & dosage , Sofosbuvir/pharmacokinetics , Adolescent , Adult , Area Under Curve , Chromatography, Liquid , Cross-Over Studies , Drug Compounding , Drug Therapy, Combination , Egypt/epidemiology , Female , Healthy Volunteers , Humans , Male , Middle Aged , Reference Standards , Tablets , Tandem Mass Spectrometry , Therapeutic Equivalency , Young Adult
7.
J Pharm Biomed Anal ; 98: 1-8, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24863555

ABSTRACT

A rapid, simple, sensitive and specific LC-MS/MS method has been developed and validated for the simultaneous estimation of amlodipine (AML), benazepril (BEN) and benazeprilat (BNT) using eplerenone and torsemide as internal standards (IS). The Xevo TQD LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. Sample preparation involves both extraction and precipitation techniques. The reconstituted samples were chromatographed on Acquity UPLC BEH C18 (50mm×2.1mm, 1.7µm) column by pumping 0.1% formic acid and acetonitrile in a gradient mode at a flow rate of 0.45ml/min. A detailed validation of the method was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 0.1-5ng/ml for AML; 5-1200ng/ml for both BEN and BNT. The intra-day and inter-day precision and accuracy results were within the acceptable limits. A run time of 2.5min for each sample made it possible to analyze more than 300 human plasma samples per day. The developed assay method was successfully applied to a bioequivalence study in human volunteers.


Subject(s)
Amlodipine/blood , Benzazepines/blood , Plasma/chemistry , Chromatography, High Pressure Liquid/methods , Humans , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Therapeutic Equivalency
SELECTION OF CITATIONS
SEARCH DETAIL
...