Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Bioengineering (Basel) ; 10(9)2023 Aug 29.
Article in English | MEDLINE | ID: mdl-37760120

ABSTRACT

Bone analyses using mid-infrared spectroscopy are gaining popularity, especially with handheld spectrometers that enable on-site testing as long as the data quality meets standards. In order to diagnose Staphylococcus epidermidis in human bone grafts, this study was carried out to compare the effectiveness of the Agilent 4300 Handheld Fourier-transform infrared with the Perkin Elmer Spectrum 100 attenuated-total-reflectance infrared spectroscopy benchtop instrument. The study analyzed 40 non-infected and 10 infected human bone samples with Staphylococcus epidermidis, collecting reflectance data between 650 cm-1 and 4000 cm-1, with a spectral resolution of 2 cm-1 (Agilent 4300 Handheld) and 0.5 cm-1 (Perkin Elmer Spectrum 100). The acquired spectral information was used for spectral and unsupervised classification, such as a principal component analysis. Both methods yielded significant results when using the recommended settings and data analysis strategies, detecting a loss in bone quality due to the infection. MIR spectroscopy provides a valuable diagnostic tool when there is a tissue shortage and time is of the essence. However, it is essential to conduct further research with larger sample sizes to verify its pros and cons thoroughly.

2.
Int J Mol Sci ; 25(1)2023 Dec 30.
Article in English | MEDLINE | ID: mdl-38203710

ABSTRACT

Osteomyelitis is a bone disease caused by bacteria that can damage bone. Raman handheld spectroscopy has emerged as a promising diagnostic tool for detecting bone infection and can be used intraoperatively during surgical procedures. This study involved 120 bone samples from 40 patients, with 80 samples infected with either Staphylococcus aureus or Staphylococcus epidermidis. Raman handheld spectroscopy demonstrated successful differentiation between healthy and infected bone samples and between the two types of bacterial pathogens. Raman handheld spectroscopy appears to be a promising diagnostic tool in bone infection and holds the potential to overcome many of the shortcomings of traditional diagnostic procedures. Further research, however, is required to confirm its diagnostic capabilities and consider other factors, such as the limit of pathogen detection and optimal calibration standards.


Subject(s)
Bone Diseases , Osteomyelitis , Humans , Osteomyelitis/diagnosis , Calibration , Health Status , Spectrum Analysis, Raman
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 262: 120085, 2021 Dec 05.
Article in English | MEDLINE | ID: mdl-34174679

ABSTRACT

Near-infrared (NIR) spectroscopy is a valued analytical tool in various applications involving polymers. However, complex nature of NIR spectra imposes difficulties in their direct interpretation. Here, anharmonic quantum chemical calculations are used to simulate NIR spectra of nine polymers; acrylonitrile butadiene styrene (ABS), ethylene-vinyl acetate (EVAC), polycarbonate (PC), polyethylene terephthalate (PET), polylactide or polylactic acid (PLA), polymethylmethacrylate (PMMA), polyoxymethylene (POM), polystyrene (PS) and polyvinylchloride (PVC). The generalized spectra-structure correlations are derived for these systems with focus given to the manifestation in NIR spectra of aromatic ring, C=O, C≡N and C-Cl functionalities. It is concluded that the nature of NIR polymer bands is only moderately sensitive to the remote chemical neighborhood. The majority of NIR absorption of polymers originates from binary combination bands, while the first overtones are meaningful only in ca. 6200-5500 cm-1 region. The contribution of the overtone bands is relatively higher for the polymers bearing aromatic rings because of higher intensity of C-H stretching overtones. Highly characteristic combination bands of the modes localized in aromatic ring (ring deformation and CH stretching) are relatively independent on the remaining structure of the polymer. The combination bands originating from C=O group are more sensitive to the chemical neighborhood in near proximity, forming a useful fingerprint for a specific polymer. In contrast, the vibrational bands of C≡N functionality are far less useful in NIR region than in infrared (IR) region. With aid of the calculated absorption bands, structural specificity of NIR spectroscopy of polymers can be markedly improved.


Subject(s)
Polymers , Spectroscopy, Near-Infrared , Vibration
SELECTION OF CITATIONS
SEARCH DETAIL
...