Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Musculoskelet Disord ; 24(1): 945, 2023 Dec 06.
Article in English | MEDLINE | ID: mdl-38057743

ABSTRACT

BACKGROUND: This study aimed to compare the clinical and radiological outcomes of medial patellofemoral ligament reconstruction (MPFLR) between anatomic femoral tunnel positions at anterior and posterior footprints. METHODS: Fifty-seven patients who underwent MPFLR for patellofemoral instability with anterior or posterior femoral tunnels between 2014 and 2021 with at least 2 years of follow-up were retrospectively analyzed. Based on postoperative images, the femoral tunnel positions anterior to the line connecting the adductor tubercle and medial epicondyle were assigned to the anterior group, group A, and those posterior to the line to the posterior group, group P. Thirty-two patients were included in group A (mean age, 22.4 ± 8.8 years), and another 25 patients were included in group P (mean age, 21.1 ± 6.1 years). The International Knee Documentation Committee (IKDC) subjective score, Lysholm score, Tegner activity score, Kujala score, and complications were evaluated. Radiologically, the Caton-Deschamps index (CDI), patellar tilt angle, and patellofemoral osteoarthritis (PFOA) using the Kellgren-Lawrence (KL) scale were evaluated. The patellofemoral cartilage status according to the International Cartilage Repair Society (ICRS) grade, bone contusion, femoral tunnel enlargement, and MPFL graft signal intensity were also evaluated. RESULTS: All clinical scores significantly improved in both groups (p < 0.01). No differences were noted between the two groups in terms of their preoperative demographic data, postoperative clinical scores (IKDC, Lysholm, Tegner, and Kujala), complications, or radiological findings (CDI, patellar tilt angle, PFOA, bone contusion, femoral tunnel enlargement, and graft signal intensity). The ICRS grade for the medial facet of the patella progressed in group A (30%, p = 0.02) but not in group P (18%, p = n.s.). Additionally, no significant differences were observed in the other compartments of the patellofemoral joint. CONCLUSIONS: The clinical outcomes were significantly improved in both groups; however, MPFLR with anterior femoral tunnel position had worse cartilage status on the medial facet of the patella than the posterior femoral tunnel position. LEVEL OF EVIDENCE: Level III.


Subject(s)
Contusions , Joint Instability , Osteoarthritis, Knee , Patellar Dislocation , Patellofemoral Joint , Humans , Adolescent , Young Adult , Adult , Patellar Dislocation/diagnostic imaging , Patellar Dislocation/surgery , Retrospective Studies , Joint Instability/surgery , Patellofemoral Joint/diagnostic imaging , Patellofemoral Joint/surgery , Ligaments, Articular/diagnostic imaging , Ligaments, Articular/surgery , Patella
2.
Telemed J E Health ; 20(12): 1093-102, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25405527

ABSTRACT

We propose CardioGuard, a brassiere-based reliable electrocardiogram (ECG) monitoring sensor system, for supporting daily smartphone healthcare applications. It is designed to satisfy two key requirements for user-unobtrusive daily ECG monitoring: reliability of ECG sensing and usability of the sensor. The system is validated through extensive evaluations. The evaluation results showed that the CardioGuard sensor reliably measure the ECG during 12 representative daily activities including diverse movement levels; 89.53% of QRS peaks were detected on average. The questionnaire-based user study with 15 participants showed that the CardioGuard sensor was comfortable and unobtrusive. Additionally, the signal-to-noise ratio test and the washing durability test were conducted to show the high-quality sensing of the proposed sensor and its physical durability in practical use, respectively.


Subject(s)
Activities of Daily Living , Clothing , Electrocardiography/instrumentation , Monitoring, Physiologic/instrumentation , Smartphone , Female , Humans , Patient Satisfaction , Surveys and Questionnaires
3.
Phys Chem Chem Phys ; 15(45): 19584-94, 2013 Dec 07.
Article in English | MEDLINE | ID: mdl-24068365

ABSTRACT

Polyetheral additives were found to be efficient promoters to enhance the rate of H2-release from ammonia borane (AB) at various temperatures. In particular, tetraethylene glycol dimethyl ether (T4EGDE, 29 wt% relative to AB + T4EGDE) exhibited significantly improved activities for AB dehydrogenation, with the material-based hydrogen storage capacity of 10.3 wt% at 125 °C within 40 min. In situ FT-IR spectroscopy indicated the formation of B-(cyclodiborazanyl)amino-borohydride (BCDB), borazine, and µ-aminodiborane as gaseous byproducts. In addition, (11)B nuclear magnetic resonance (NMR) spectroscopy further revealed that diammoniate of diborane (DADB) was initially formed to give polyaminoborane as liquid and/or solid spent-fuel, consistent with previous reports. Density Functional Theory (DFT) calculations suggested that hydrogen bonding interactions between AB and a polyetheral promoter initially played an important role in increasing the reactivity of B-H bonds of AB by transferring electron density from oxygen atoms of the promoter into B-H bonds of AB. These partially activated, hydridic B-H bonds were proposed to help promote the formation of diammoniate of diborane (DADB), which is considered as a reactive intermediate, eventually enhancing the rate of H2-release from AB. In addition, our in situ solid state (11)B magic angle spinning (MAS) NMR measurements further confirmed that the rate of DADB formation from AB with a small quantity of T4EGDE was found to be much faster than that of pristine AB even at 50 °C. This metal-free method for H2-release from AB with an added, small quantity of polyethers would be helpful to develop feasible hydrogen storage systems for long-term fuel cell applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...