Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Orthop Surg ; 16(3): 390-396, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827754

ABSTRACT

Background: The purpose of this study was to evaluate functional outcomes, radiologic results, and complications after hybrid total hip arthroplasty (THA) in patients with subchondral insufficiency fractures (SIFs) of the femoral head. Methods: From June 2009 to December 2020, among 985 patients who underwent hybrid THA at our hospital, 19 patients diagnosed with SIF through a retrospective chart review were included. Those under 50 years of age, with radiographic findings of osteonecrosis on the contralateral side of surgery, a history of organ transplantation, and alcohol abuse, were excluded. Functional evaluation was performed using a modified Harris Hip Score (HHS). After surgery, inclination and anteversion of the acetabular cup and version of the femoral system were measured using postoperative x-ray. The outpatient follow-up was performed at 6 weeks, 3 months, 9 months, and 12 months after surgery and every year thereafter. Complications including dislocation, implant loosening, stem subsidence, and periprosthetic infection were observed on follow-up radiographs. Results: The average follow-up time was 29.3 ± 9.1 months (range, 24-64 months) with no loss to follow-up. The mean modified HHS was 83.4 ± 9.6 (range, 65-100) at the last outpatient clinic follow-up. The average inclination of the acetabular cup was 41.9° ± 3.4° (range, 37°-48°), and the anteversion was 27.5° ± 6.7° (range, 18°-39°). The version of the femoral stem was 19° ± 5.7° (range, 12°-29°). There was no case of intraoperative fracture. There were no cases of dislocation, loosening of the cup, subsidence of the femoral stem, intraoperative or periprosthetic fracture, or periprosthetic infection on the follow-up radiographs. Conclusions: In our study, hybrid THA showed favorable outcomes in patients diagnosed with SIF, and there were no further special considerations as for THA performed due to other diseases or fractures.


Subject(s)
Arthroplasty, Replacement, Hip , Fractures, Stress , Humans , Arthroplasty, Replacement, Hip/adverse effects , Middle Aged , Male , Female , Retrospective Studies , Fractures, Stress/surgery , Fractures, Stress/diagnostic imaging , Fractures, Stress/etiology , Adult , Femur Head/surgery , Femur Head/diagnostic imaging , Femur Head/injuries , Aged , Hip Fractures/surgery , Hip Fractures/diagnostic imaging , Postoperative Complications
SELECTION OF CITATIONS
SEARCH DETAIL
...