Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Environ Sci Process Impacts ; 22(10): 2117-2131, 2020 Oct 01.
Article in English | MEDLINE | ID: mdl-32969449

ABSTRACT

Veterinary drugs, such as coccidiostats and anthelmintics are routinely administered in extensive animal husbandry, finding their way into the aquatic environment through urine and/or feces of treated animals kept outdoors or by the application of contaminated liquid manure on agricultural fields and subsequent mechanisms of surface run-off, leaching and drift. Several of these compounds are known to exert acute and chronic toxicity effects on aquatic organisms, and can lead to changes in biodiversity and ecosystem functioning. The overall objective of this research was to develop, validate and apply a highly sensitive, multi-residue SPE-UHPLC-MS/MS method for the determination of 12 coccidiostats, registered as a feed supplement or veterinary medicine in Europe and three regularly used anthelmintics, in pond water, often functioning as amphibian habitat. Sample extraction was optimized using a fractional factorial resolution design. Pond water filtration efficiency (i.e. 80-118%, ≤25% RSD) and matrix effects (i.e. 72-119%, ≤39% RSD) were evaluated using water from respectively 3 and 20 different ponds in Flanders. By incorporating internal standards, overall results improved and adequate precision values (i.e.≤15%) were obtained according to the EMA guidelines. Acceptable within-run and between-run apparent recoveries, satisfactory precision as well as good linearity were demonstrated according to the CD 2002/657/EC, SANTE/12682/2019 and VICH 49 guidelines, except for robenidine for which the between-day precision was between 21.0 and 34.5%. Sample storage stability studies indicated that storage at 4 °C and analysis performed within 96 hours after sampling was sufficient to avoid loss by degradation for all compounds, excluding robenidine. Values for the limit of detection (LOD) and quantification (LOQ) were in nanograms per liter, which was essential for the environmental application of this novel method. The method was successfully applied on grab water samples from the water surface of 18 different ponds across Flanders, Belgium, detecting amprolium and levamisole at concentrations below the LOQ of 2.5 ng L-1 and at 250.0 ng L-1 or below the LOQ of 250.0 ng L-1, respectively. In conclusion, our newly developed method may provide insights about the contamination status of amphibian breeding ponds.


Subject(s)
Anthelmintics , Coccidiostats , Veterinary Drugs , Animals , Belgium , Chromatography, High Pressure Liquid , Ecosystem , Europe , Fresh Water , Ponds , Tandem Mass Spectrometry
2.
J Mass Spectrom ; 35(11): 1342-50, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11114094

ABSTRACT

Gentamicin is a broad-spectrum aminoglycoside antibiotic widely used in veterinary medicine for the treatment of serious infections. The purpose of this study was to develop and validate a method to determine gentamicin residues in edible tissues of swine and calf. Extraction of gentamicin was performed using a liquid extraction with phosphate buffer containing trichloroacetic acid, followed by a solid-phase clean-up procedure on a CBA weak cation-exchange column. Tobramycin was used as the internal standard. After drying of the eluate, the residue was redissolved and further analyzed by reversed-phase liquid chromatography/electrospray ionization tandem mass spectrometry (MS/MS). Chromatographic separation of the internal standard tobramycin and the gentamicin components was achieved on a Nucleosil (5 microm) column using a mixture of 10 mM pentafluoropropionic acid in water and acetonitrile as the mobile phase. The gentamicin components C1a, C2 + C2a and C1 could be identified with the MS/MS detection, and subsequently quantified. The method was validated according to the requirements of the EC at the maximum residue limit (MRL) (100 ng g(-1) for muscle and fat, 200 ng g(-1) for liver and 1000 ng g(-1) for kidney), half the MRL and double the MRL levels. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r > 0.99 and goodness of fit <10%). Limits of quantification of 25.0 ng g(-1) were obtained for the determination of gentamicin in muscle, fat, liver and kidney tissues of swine and calf, which correspond in all cases to at least half the MRLs. Limits of detection ranged between 0.5 and 2.5 ng g(-1) for the tissues. The within-day and between-day precisions (RSD) and the results for accuracy fell within the ranges specified. The method was successfully used for the determination of gentamicin in tissue samples of swines and calves medicated with gentamicin by intramuscular injection.


Subject(s)
Anti-Bacterial Agents/analysis , Chromatography, High Pressure Liquid/methods , Gentamicins/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Animals , Anti-Bacterial Agents/isolation & purification , Anti-Bacterial Agents/pharmacokinetics , Calibration , Cattle , Gentamicins/isolation & purification , Gentamicins/pharmacokinetics , Molecular Structure , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, Mass, Electrospray Ionization/instrumentation , Swine , Tobramycin/analysis
SELECTION OF CITATIONS
SEARCH DETAIL