Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
2.
Crit Care Med ; 42(9): 2019-28, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24810522

ABSTRACT

OBJECTIVES: The primary aim of the study was to measure the test characteristics of the National Health Safety Network ventilator-associated event/ventilator-associated condition constructs for detecting ventilator-associated pneumonia. Its secondary aims were to report the clinical features of patients with National Health Safety Network ventilator-associated event/ventilator-associated condition, measure costs of surveillance, and its susceptibility to manipulation. DESIGN: Prospective cohort study. SETTING: Two inpatient campuses of an academic medical center. PATIENTS: Eight thousand four hundred eight mechanically ventilated adults discharged from an ICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs detected less than a third of ventilator-associated pneumonia cases with a sensitivity of 0.325 and a positive predictive value of 0.07. Most National Health Safety Network ventilator-associated event/ventilator-associated condition cases (93%) did not have ventilator-associated pneumonia or other hospital-acquired complications; 71% met the definition for acute respiratory distress syndrome. Similarly, most patients with National Health Safety Network probable ventilator-associated pneumonia did not have ventilator-associated pneumonia because radiographic criteria were not met. National Health Safety Network ventilator-associated event/ventilator-associated condition rates were reduced 93% by an unsophisticated manipulation of ventilator management protocols. CONCLUSIONS: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs failed to detect many patients who had ventilator-associated pneumonia, detected many cases that did not have a hospital complication, and were susceptible to manipulation. National Health Safety Network ventilator-associated event/ventilator-associated condition surveillance did not perform as well as ventilator-associated pneumonia surveillance and had several undesirable characteristics.


Subject(s)
Intensive Care Units/statistics & numerical data , Pneumonia, Ventilator-Associated/epidemiology , Public Health Surveillance/methods , APACHE , Academic Medical Centers/statistics & numerical data , Female , Hospital Mortality , Humans , Length of Stay , Male , Middle Aged , Patient Safety , Pneumonia, Ventilator-Associated/mortality , Prevalence , Prospective Studies , Quality Indicators, Health Care , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...