Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 94(5)2023 May 01.
Article in English | MEDLINE | ID: mdl-37166247

ABSTRACT

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System [Waxer et al., Opt. Photonics News 16, 30 (2005)] is a diagnostic that is used to measure the backscattered and sidescattered light during laser-plasma interaction experiments [W. L. Kruer, The Physics of Laser Plasma Interactions, Frontiers in Physics Vol. 73, edited by D. Pines (Addison-Wesley, Redwood City, CA, 1988) and Myatt et al., Phys. Plasmas 21, 055501 (2014)] that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420-720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-µm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (∼1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Additional offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

2.
Rev Sci Instrum ; 92(3): 033511, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33820108

ABSTRACT

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm-352 nm), stimulated Raman scattering (430 nm-760 nm), and ω/2 (695 nm-745 nm). SLTD measures scattered light with a time resolution of ∼1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

3.
Phys Rev Lett ; 125(25): 255002, 2020 Dec 18.
Article in English | MEDLINE | ID: mdl-33416398

ABSTRACT

The effectiveness of a dome-shaped wall covered by a thin gold foil (hollow wall) [M. Vandenboomgaerde et al., Phys. Plasmas 25, 012713 (2018)PHPAEN1070-664X10.1063/1.5008669] in holding back the high-Z plasma expansion in a gas-filled hohlraum is demonstrated for the first time in experiments reproducing the irradiation conditions of indirect drive at the ignition scale. The setup exploits a 1D geometry enabling record of the complete history of the gold expansion for 8 ns by imaging its emission in multiple x-ray energy ranges featuring either the absorption zones or the thermal emission regions. The measured expansion dynamics is well reproduced by numerical simulations. This novel wall design could now be tailored for the megajoule scale to enable the propagation of the inner beams up to the equator in low gas-filled hohlraum thus allowing the fine-tuning of the irradiation symmetry on the timescale required for ignition.

4.
Rev Sci Instrum ; 88(9): 093702, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28964245

ABSTRACT

A 16-image Kirkpatrick-Baez (KB)-type x-ray microscope consisting of compact KB mirrors [F. J. Marshall, Rev. Sci. Instrum. 83, 10E518 (2012)] has been assembled for the first time with mirrors aligned to allow it to be coupled to a high-speed framing camera. The high-speed framing camera has four independently gated strips whose emission sampling interval is ∼30 ps. Images are arranged four to a strip with ∼60-ps temporal spacing between frames on a strip. By spacing the timing of the strips, a frame spacing of ∼15 ps is achieved. A framed resolution of ∼6-µm is achieved with this combination in a 400-µm region of laser-plasma x-ray emission in the 2- to 8-keV energy range. A principal use of the microscope is to measure the evolution of the implosion stagnation region of cryogenic DT target implosions on the University of Rochester's OMEGA Laser System [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. The unprecedented time and spatial resolutions achieved with this framed, multi-image KB microscope have made it possible to accurately determine the cryogenic implosion core emission size and shape at the peak of stagnation. These core size measurements, taken in combination with those of ion temperature, neutron-production temporal width, and neutron yield allow for inference of core pressures, currently exceeding 50 Gbar in OMEGA cryogenic target implosions [Regan et al., Phys. Rev. Lett. 117, 025001 (2016)].

5.
Rev Sci Instrum ; 83(10): 10E107, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126929

ABSTRACT

The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO∕QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals.

6.
Rev Sci Instrum ; 79(10): 10E904, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044559

ABSTRACT

A high-resolution x-ray imager (HRXI) devoted to laser-plasma experiments combines two state-of-the-art technologies developed in France: a high-resolution x-ray microscope and a high-speed x-ray streak camera. The resulting streaked imager achieves spatial and temporal resolutions of approximately 5 microm and approximately 10 ps, respectively. The HXRI has recorded enhanced spatial and temporal resolution radiographs of indirectly driven targets on OMEGA. This paper describes the main features of the instrument and details the activation process on OMEGA (particularly the alignment). Recent results obtained on joint CEA/LLE radiographic OMEGA experiments will also be presented.

7.
Phys Rev Lett ; 90(23): 235002, 2003 Jun 13.
Article in English | MEDLINE | ID: mdl-12857266

ABSTRACT

Experiments with multiple laser beams have been carried out in both spherical and planar geometry to study two-plasmon-decay instability, the predominant source of suprathermal electrons in direct-drive inertial confinement fusion experiments. These electrons are observed using the hard x rays generated through electron-target interactions. The experiments show for the first time that the total overlapped intensity governs the scaling of the suprathermal-electron generation regardless of the number of overlapped beams, in contrast to conventional theories that are based on the single-beam approximation.

SELECTION OF CITATIONS
SEARCH DETAIL
...