1.
J Child Orthop ; 18(1): 40-48, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38348436

ABSTRACT

Objective: This review provides guidance and ideas for researchers through a comprehensive and comparative analysis of the present state, trends, and hotspots in the pediatric fracture literature over the past 6 years. Methods: We used Citespace 6.1.R6 software to explore the country/region distribution, institutions, journals, keyword analysis, and co-cited references of the literature from Web of Science core database. Results: There are 6472 pieces of pediatric fracture-related literature, including 2962 from 2017 to 2019 and 3510 from 2020 to 2022. The country with the most papers is the United States, and US institutions and journals also have a pivotal position in this field. Research hotspots for pediatric fractures in 2017-2019: The topic with the most attention is bone mineral density leading to related bone diseases. Treatment for pediatric fractures, including supracondylar humeral fractures, Monteggia fractures, forearm fractures, knee fractures, and ankle fractures in children, is another topic of greater interest. Brain injuries and dental injuries in children due to abuse and trauma are also concerning issues. Research hotspots for pediatric fractures in 2020-2022: comparison with 2017-2019 revealed a relative decrease regarding ankle-related epiphyseal injuries, but there is a higher focus on the epidemiology of fractures in children, risk factors, and reasons for childhood trauma. We have confirmed through literature co-citations that the literature of high interest is also in these aspects. Conclusion: Researchers and clinicians can quickly learn about topics of interest through authoritative journals and highly cited literature and rapidly master the current status and frontiers of the field through study, providing ideas for future work.

2.
Sci Rep ; 13(1): 20114, 2023 11 17.
Article in English | MEDLINE | ID: mdl-37978302

ABSTRACT

Surgical management of posterolateral tibial plateau (PLTP) fractures is challenging. One reason for this challenge is the lack of suitable internal fixation devices. Our aim was to introduce a novel plate via the anterolateral approach for managing PLTP fractures. The biomechanical testing and finite element analysis (FEA) were performed. PLTP fracture models were created using synthetic tibias (n = 10 within each group). These models were randomly assigned to three groups (groups A-C) and fixed with the lateral locking plate, the posterior buttress plate, and the novel plate, respectively. The vertical displacement of the posterolateral fragments was evaluated using biomechanical testing and FEA under axial loads of 250 N, 500 N, and 750 N. We also evaluated the stress distribution and maximum stress of each fracture model using FEA. Biomechanically, under the same loads of 250 N, 500 N, or 750 N, the vertical displacement was significantly different among the three fixation groups (p ≤ 0.001). FEA data indicated that the maximum displacement from group A to C was 3.58 mm, 3.23 mm, and 2.78 mm at 750 N, respectively. The maximum stress from group A to C was 220.88 MPa, 194.63 MPa, and 156.77 MPa in implants, and 62.02 MPa, 77.71 MPa, and 54.15 MPa in bones at 750 N, respectively. The general trends at 250 N and 500 N were consistent with those at 750 N. Based on our biomechanical and FEA results, the novel plate could be a good option for treating PLTP fractures. The novel plate showed stable and reliable features, indicating its suitability for further clinical application.


Subject(s)
Tibial Fractures , Tibial Plateau Fractures , Humans , Tibia/surgery , Biomechanical Phenomena , Finite Element Analysis , Fracture Fixation, Internal/methods , Tibial Fractures/surgery
3.
Front Bioeng Biotechnol ; 11: 1279067, 2023.
Article in English | MEDLINE | ID: mdl-38026862

ABSTRACT

Purpose: How to effectively enhance the mechanical stability of intramedullary implants for unstable femoral intertrochanteric fractures (UFIFs) is challenging. The authors developed a new implant for managing such patients. Our aim was to enhance the whole mechanical stability of internal devices through increasing antirotation and medial support. We expected to reduce stress concentration in implants. Each implant was compared to proximal femoral nail antirotation (PFNA) via finite element method. Methods: Adult AO/OTA 31-A2.3 fracture models were constructed, and then the new intramedullary system (NIS), PFNA, InterTan nail models were assembled. We simulated three different kinds of load cases, including axial, bending, and torsion loads. For further comparison of PFNA and the NIS, finite element analysis (FEA) was repeated for five times under axial loads of 2100 N. Two types of displacement and stress distribution were assessed. Results: Findings showed that the NIS had the best mechanical stability under axial, bending, and torsion load conditions compared to PFNA and InterTan. It could be seen that the NIS displayed the best properties with respect to maximal displacement while PFNA showed the worst properties for the same parameter in axial loads of 2100 N. In terms of maximal stress, also the NIS exhibited the best properties while PFNA showed the worst properties in axial loads of 2100 N. For bending and torsion load cases, it displayed a similar trend with that of axial loads. Moreover, under axial loads of 2100 N, the difference between the PFNA group and the NIS group was statistically significant (p < 0.05). Conclusion: The new intramedullary system exhibited more uniform stress distribution and better biomechanical properties compared to the PFNA and InterTan. This might provide a new and efficacious device for managing unstable femoral intertrochanteric fractures.

4.
Front Pediatr ; 11: 1210493, 2023.
Article in English | MEDLINE | ID: mdl-37554152

ABSTRACT

Objective: This study aims to find the optimal arrangement of the Kirschner wire (K-wire) in the sagittal plane for fixation of a pediatric lateral condylar humeral fracture (Milch type II) by using finite element analysis (FEA). Methods: A model of lateral condyle fracture in a 6-year-old boy was developed, and an XYZ coordinate system was established based on this model. The YZ plane was defined as the sagittal plane to investigate the impact of the angle formed by the first and second K-wires on stability. Two configurations were studied for each angle: parallel and divergent. Evaluation indicators included the maximum displacement of the fracture fragment and the maximum von Mises stress in the pins and bone. Results: The model with a -60° angle showed the best performance in both evaluation indicators. The parallel and divergent pin configurations had different performances in each group. The displacement results for negative angles were similar, and this result was better than those for positive angles. Conclusion: We successfully created a model of pediatric lateral condyle humerus fracture (Milch type II) and performed K-wire fixation with varying sagittal plane configurations, combined with FEA. Our findings demonstrate that the angle of -60° between the two pins in the sagittal plane provided the highest level of stability, with divergent configurations proving superior to parallel pinning at this angle.

5.
Sci Rep ; 13(1): 13516, 2023 08 19.
Article in English | MEDLINE | ID: mdl-37598264

ABSTRACT

For Schatzker type II split-depressed tibial plateau fractures involving the fractures of anterolateral and posterolateral columns (APC), the optimal fixation scheme is controversial. The objectives of this study were: (1) to introduce a newly designed plate for treating APC fractures via biomechanical tests and finite element analysis (FEA), and (2) to compare it with two conventional fixation methods. APC fracture models were created and randomly assigned to three groups (Groups A-C). Group A was fixed with a 3.5-mm lateral locking plate, Group B was fixed with a 3.5-mm lateral locking plate and two 3.5-mm cannulated screws (hybrid fixation). Group C was fixed with the newly designed plate. It is an arched locking plate for fixing the lateral tibial plateau via the anterolateral supra-fibular-head approach. Each fracture model experienced a gradually increasing axial compressive load ranging from 250 to 750 N using a customized indenter. Biomechanical analysis demonstrated that the newly designed plate showed the minimum displacement among the three methods, followed by the hybrid fixation method. Conversely, the 3.5-mm lateral locking plate displayed the maximum displacement in APC fractures (p < 0.05). FEA results indicated that at 750 N, the maximum displacements for Groups A-C were measured as 3.06 mm, 2.74 mm, and 2.08 mm, respectively. Moreover, the maximum stresses recorded for the implant in Groups A-C at 750 N were 208.32 MPa, 299.59 MPa, and 143.26 MPa, while for the bone, they were 47.12 MPa, 74.36 MPa, and 40.01 MPa. The overall trends at 250 N and 500 N were consistent with those observed at 750 N. In conclusion, due to good biomechanical performance and FEA results, the newly designed plate represents a promising choice for managing APC fractures of the tibial plateau.


Subject(s)
Tibial Fractures , Tibial Plateau Fractures , Humans , Biomechanical Phenomena , Finite Element Analysis , Tibia/surgery , Tibial Fractures/surgery
6.
Front Pediatr ; 11: 1131618, 2023.
Article in English | MEDLINE | ID: mdl-36969277

ABSTRACT

Background: Skeletal maturity can evaluate the growth and development potential of children and provide a guide for the management of adolescent idiopathic scoliosis (AIS). Recent studies have demonstrated the advantages of the Humeral Head Ossification System (HHOS) and the Proximal Femur Maturity Index (PFMI), based on standard scoliosis films, in the management of AIS patients. We further assessed the HHOS and the PFMI method's reliability in the interrater and intrarater. Methods: The data from 38 patients, including the humeral head and proximal femur on standard scoliosis films, were distributed to the eight raters in the form of a PowerPoint presentation. On 38 independent standard spine radiographs, raters utilized the HHOS and PFMI to assign grades. The PPT sequence was randomly changed and then reevaluated 2 weeks later. For every system, the 95% confidence interval (95% CI) and intraclass correlation coefficient (ICC) were calculated to evaluate the interrater and intrarater reliability. Results: The HHOS was extremely reliable, with an intraobserver ICC of 0.802. In the first round, the interobserver ICC reliability for the HHOS was 0.955 (0.929-0.974), while in the second round, it was 0.939 (0.905-0.964). The PFMI was extremely reliable, with an intraobserver ICC of 0.888. In the first round, the interobserver ICC reliability for the PFMI was 0.967 (0.948-0.981), while in the second round, it was 0.973 (0.957-0.984). Conclusions: The HHOS and PFMI classifications had excellent reliability. These two methods are beneficial to reduce additional exposure to radiation and expense for AIS. There are advantages and disadvantages to each classification. Clinicians should choose a personalized and reasonable method to assess skeletal maturity, which will assist in the management of adolescent scoliosis patients.

7.
Front Bioeng Biotechnol ; 11: 1116976, 2023.
Article in English | MEDLINE | ID: mdl-36896014

ABSTRACT

Purpose: The existing implants for fixation of femoral neck fractures have poor biomechanical stability, so the failure rate is high. We designed two modified intramedullary implants for treating unstable femoral neck fractures (UFNFs). We tried to improve the biomechanical stability of fixation by shortening the moment and reducing stress concentration. Each modified intramedullary implant was compared with cannulated screws (CSs) through finite element analysis (FEA). Methods: Five different models were included: three cannulated screws (CSs, Model 1) in an inverted triangle configuration, the dynamic hip screw with an anti-rotation screw (DHS + AS, Model 2), the femoral neck system (FNS, Model 3), the modified intramedullary femoral neck system (IFNS, Model 4), and the modified intramedullary interlocking system (IIS, Model 5). Three-dimensional (3D) models of femur and implants were constructed by using 3D modelling software. Three load cases were simulated to assess the maximal displacement of models and fracture surface. The maximal stress at the bone and implants was also evaluated. Results: FEA data showed that Model 5 had the best performance in terms of maximum displacement while Model 1 had the worst performance for this index under axial load of 2100 N. With respect to Maximum stress, Model 4 had the best performance while Model 2 had the worst performance under axial load. The general trends under bending and torsion load were consistent with that under axial load. Our data demonstrated that the two modified intramedullary implants exhibited the best biomechanical stability, followed by FNS and DHS + AS, and then three cannulated screws in axial, bending, and torsion load cases. Conclusion: The two modified intramedullary designs showed the best biomechanical performance among the five implants included in this study. Therefore, this might provide some new options for trauma surgeons to deal with unstable femoral neck fractures.

8.
Front Bioeng Biotechnol ; 10: 1010508, 2022.
Article in English | MEDLINE | ID: mdl-36324895

ABSTRACT

Objective: This study aimed to compare the biomechanical stability and clinical efficacy of the Kirschner-wire (K-wire) tension band combined with patellar cerclage and an anchor-loop plate (ALP) in treating inferior-pole patellar fracture. Methods: The finite element model was established to analyze the mechanical properties of a K-wire tension band combined with patellar cerclage and ALP fixation in the treatment of inferior patellar pole fracture. The clinical data of 49 patients with patellar inferior-pole fracture (AO/OTA 34 A1) admitted to our hospital from January 2017 to July 2021 were retrospectively analyzed. Among these, 28 cases were fixed with ALPs (ALP group) and 21 cases were fixed with K-wire tension bands combined with patellar cerclage (K-wire group). By reviewing the medical records and follow-up results, we compared the operation time, final knee joint activity, incidence of secondary surgery, postoperative complications, and joint function recovery between the two groups. Results: The biomechanical analysis of the finite element model showed that the maximum displacement of the K-wire group was 1.87 times that of the ALP group. The maximum stress of the K-wire group was 1.34 times that of the ALP group. The maximum stress of the pole bone in the K-wire group was 13.89 times that of the ALP group. The average follow-up times of the K-wire group and ALP group were similar (p > 0.05), and the average ages of the two groups were similar (p > 0.05). The operation time of the ALP group was significantly shorter than that of the K-wire group (p < 0.05).The final knee joint activity of the ALP group was significantly greater than that of the K-wire group (p < 0.05). The Bostman patellar fracture function score of the ALP group was significantly better than that of the K-wire group at 3 and 9 months after operation (p < 0.05). Postoperative complications of the two groups included 1 case (3.6%) in the ALP group with internal fixation-stimulation complications and, in the K-wire group, 3 cases (14.3%) with internal fixation stimulation complications and 1 case (4.8%) with infection. Conclusion: The ALP and K-wire tension band combined with patella cerclage models were tested at 500 N, and no damage occurred, indicating that the newly designed ALP is safe in mechanical structure. The ALP has better therapeutic effect in biomechanical stability, postoperative complications, secondary surgery, and knee function. This technique is an effective method for the treatment of inferior-pole patellar fracture.