Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 83(10): 10E104, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126926

ABSTRACT

Based on the multi-foil technique, a multichannel soft x-ray diagnostic for electron temperature measurements has been recently implemented in the TJ-II stellarator. The diagnostic system is composed by four photodiodes arrays with beryllium filters of different thickness. An in-vacuum amplifier board is coupled to each array, aiming at preventing induced noise currents. The Thomson scattering and the vacuum ultraviolet survey diagnostics are used for assessing plasma profiles and composition, being the analysis carried out with the radiation code IONEQ. The electron temperature is determined through the different signal-pair ratios with temporal and spatial resolution. The design and preliminary results from the diagnostic are presented.

2.
Rev Sci Instrum ; 83(5): 053501, 2012 May.
Article in English | MEDLINE | ID: mdl-22667616

ABSTRACT

The core electron temperature (T(e0)) of neutral beam heated plasmas is determined in TJ-II stellarator by using soft x ray detectors with beryllium filters of different thickness, based on the method known as the foil absorption technique. T(e0) estimations are done with the impurity code IONEQ, making use of complementary information from the TJ-II soft x ray tomography and the VUV survey diagnostics. When considering the actual electron density and temperature profile shapes, an acceptable agreement is found with Thomson scattering measurements for 8 different magnetic configurations. The impact of the use of both neutral beam injectors on the T(e0) measurements is addressed. Also, the behaviour of T(e0) during spontaneous profile transitions is presented.

3.
Rev Sci Instrum ; 81(10): 10D711, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21033904

ABSTRACT

The design and preliminary results from a prototype of a multifilter based electron temperature diagnostic for the TJ-II stellarator are presented. The diagnostic consists of four photodiodes with filters of different thicknesses to determine the electron temperature in a wide variety of plasma compositions, thanks to the set of six different signal-pairs ratios available. The impurity transport code IONEQ, the TJ-II soft x-ray tomography, and the VUV survey diagnostics give the necessary information to assess the proposed diagnostic reliability. In parallel, a vacuum-compatible multichannel electronic board has been designed for a future linear array to determine electron temperature profiles in high-density plasmas.

SELECTION OF CITATIONS
SEARCH DETAIL
...