Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Bioanal Chem ; 396(6): 2273-83, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20127323

ABSTRACT

The class of fatty alcohol alkoxylates describes surfactants that are synthesised by reaction of fatty alcohols with alkoxides such as ethylene oxide or propylene oxide or a combination of both as copolymers. Such alkoxylates are used, for example, as nonionic surfactants in home and industrial cleaning and washing agents. Chemical characteristics of such alkoxylate copolymers, for example the degree of alkoxylation, the arrangement of building blocks (random or block polymerisation), the type of the starter, and endcapping, play an important role in application behaviour. The analysis of these characteristics is challenging because in many cases such copolymers have high polydispersity and a large number of constitutional isomers depending on the degree of alkoxylation. Furthermore, the alkoxylates often occur in a complex multicomponent matrix. Here we present a method for characterization of silylated fatty alcohol alkoxylates in the low-molecular-weight range by means of comprehensive two-dimensional gas chromatography-mass spectrometry with electron impact and chemical ionisation. This method also enables detailed analysis of the alkoxylates in a complex matrix such as modern detergents.

2.
J Chromatogr A ; 1067(1-2): 245-54, 2005 Mar 04.
Article in English | MEDLINE | ID: mdl-15844530

ABSTRACT

The principles, practicability and potential of comprehensive two-dimensional (2D) gas chromatography coupled to a rapid-scanning quadrupole mass spectrometer (GC x GC-qMS) for the analysis of complex flavour mixtures in food, allergens in fragrances and polychlorinated biphenyls (PCBs) were studied. With a scan speed of 10,000 amu/s, monitoring over a mass range of up to 200 atomic mass unit (amu) can be achieved at an acquisition frequency of 33 Hz. Extending this mass range and/or increasing the data acquisition frequency results in a loss of spectral quality. Optimal parameter settings allow, next to unambiguous identification/confirmation of target compounds on the basis of high-quality mass spectra, fully satisfactory quantification (three to four modulations per peak) with linear calibration plots and detection limits in the low-pg level. The potential of time-scheduled data acquisition to increase the effective mass range within one GC x GC run was also explored. The analyses, with baseline separation of the flavours, allergens and PCB target compounds, took less than 30 min.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Allergens/analysis , Flavoring Agents/analysis , Gas Chromatography-Mass Spectrometry/instrumentation , Olive Oil , Plant Oils/chemistry , Polychlorinated Biphenyls/analysis , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...