Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
medRxiv ; 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38883792

ABSTRACT

BACKGROUND: Immune-checkpoint inhibitors (ICI) are associated with life-threatening myocarditis but milder presentations are increasingly recognized. The same autoimmune process that causes ICI-myocarditis can manifest concurrent generalized myositis, myasthenia-like syndrome, and respiratory muscle failure. Prognostic factors for this 'cardiomyotoxicity' are lacking. METHODS: A multicenter registry collected data retrospectively from 17 countries between 2014-2023. A multivariable cox regression model (hazard-ratio(HR), [95%confidence-interval]) was used to determine risk factors for the primary composite outcome: severe arrhythmia, heart failure, respiratory muscle failure, and/or cardiomyotoxicity-related death. Covariates included demographics, comorbidities, cardio-muscular symptoms, diagnostics, and treatments. Time-dependent covariates were used and missing data were imputed. A point-based prognostic risk score was derived and externally validated. RESULTS: In 748 patients (67% male, age 23-94), 30-days incidence of the primary composite outcome, cardiomyotoxic death, and overall death were 33%, 13%, and 17% respectively. By multivariable analysis, the primary composite outcome was associated with active thymoma (HR=3.60[1.93-6.72]), presence of cardio-muscular symptoms (HR=2.60 [1.58-4.28]), low QRS-voltage on presenting electrocardiogram (HR for ≤0.5mV versus >1mV=2.08[1.31-3.30]), left ventricular ejection fraction (LVEF) <50% (HR=1.78[1.22-2.60]), and incremental troponin elevation (HR=1.86 [1.44-2.39], 2.99[1.91-4.65], 4.80[2.54-9.08], for 20, 200 and 2000-fold above upper reference limit, respectively). A prognostic risk score developed using these parameters showed good performance; 30-days primary outcome incidence increased gradually from 3.9%(risk-score=0) to 81.3%(risk-score=4). This risk-score was externally validated in two independent French and US cohorts. This risk score was used prospectively in the external French cohort to identify low risk patients who were managed with no immunosuppression resulting in no cardio-myotoxic events. CONCLUSIONS: ICI-myocarditis can manifest with high morbidity and mortality. Myocarditis severity is associated with magnitude of troponin, thymoma, low-QRS voltage, depressed LVEF, and cardio-muscular symptoms. A risk-score incorporating these features performed well.

2.
Circulation ; 148(6): 473-486, 2023 08 08.
Article in English | MEDLINE | ID: mdl-37317858

ABSTRACT

BACKGROUND: Immune checkpoint inhibitors (ICIs) are approved for multiple cancers but can result in ICI-associated myocarditis, an infrequent but life-threatening condition. Elevations in cardiac biomarkers, specifically troponin-I (cTnI), troponin-T (cTnT), and creatine kinase (CK), are used for diagnosis. However, the association between temporal elevations of these biomarkers with disease trajectory and outcomes has not been established. METHODS: We analyzed the diagnostic accuracy and prognostic performances of cTnI, cTnT, and CK in patients with ICI myocarditis (n=60) through 1-year follow-up in 2 cardio-oncology units (APHP Sorbonne, Paris, France and Heidelberg, Germany). A total of 1751 (1 cTnT assay type), 920 (4 cTnI assay types), and 1191 CK sampling time points were available. Major adverse cardiomyotoxic events (MACE) were defined as heart failure, ventricular arrhythmia, atrioventricular or sinus block requiring pacemaker, respiratory muscle failure requiring mechanical ventilation, and sudden cardiac death. Diagnostic performance of cTnI and cTnT was also assessed in an international ICI myocarditis registry. RESULTS: Within 72 hours of admission, cTnT, cTnI, and CK were increased compared with upper reference limits (URLs) in 56 of 57 (98%), 37 of 42 ([88%] P=0.03 versus cTnT), and 43 of 57 ([75%] P<0.001 versus cTnT), respectively. This increased rate of positivity for cTnT (93%) versus cTnI ([64%] P<0.001) on admission was confirmed in 87 independent cases from an international registry. In the Franco-German cohort, 24 of 60 (40%) patients developed ≥1 MACE (total, 52; median time to first MACE, 5 [interquartile range, 2-16] days). The highest value of cTnT:URL within the first 72 hours of admission performed best in terms of association with MACE within 90 days (area under the curve, 0.84) than CK:URL (area under the curve, 0.70). A cTnT:URL ≥32 within 72 hours of admission was the best cut-off associated with MACE within 90 days (hazard ratio, 11.1 [95% CI, 3.2-38.0]; P<0.001), after adjustment for age and sex. cTnT was increased in all patients within 72 hours of the first MACE (23 of 23 [100%]), whereas cTnI and CK values were less than the URL in 2 of 19 (11%) and 6 of 22 (27%) of patients (P<0.001), respectively. CONCLUSIONS: cTnT is associated with MACE and is sensitive for diagnosis and surveillance in patients with ICI myocarditis. A cTnT:URL ratio <32 within 72 hours of diagnosis is associated with a subgroup at low risk for MACE. Potential differences in diagnostic and prognostic performances between cTnT and cTnI as a function of the assays used deserve further evaluation in ICI myocarditis.


Subject(s)
Myocarditis , Humans , Myocarditis/chemically induced , Myocarditis/diagnosis , Immune Checkpoint Inhibitors , Biomarkers , Creatine Kinase , Prognosis , Troponin T
3.
ACS Omega ; 5(20): 11507-11514, 2020 May 26.
Article in English | MEDLINE | ID: mdl-32478239

ABSTRACT

In this paper, authors propose a study on microwave gas sensors and the influence of critical key parameters such as the sensitive material and the circuit conception process. This work aims to determine the influence of these parameters on the quality of the final response of the microwave gas sensor. The fixed geometry of the sensor is a microstrip interdigital capacitor coated with a sensitive layer excited with two 50 Ω SMA ports. The sensitive material has been chosen in order to interact with the target gas: ammonia. Indeed, this gas interacts with phthalocyanine and metal oxides like hematite, TiO2. To explore the effect of the circuit manufacturing process, three series of samples are prepared. The first series of sensors is produced by classical UV photolithography (process) in the laboratory. The second series of sensors is produced by a subcontractor specialized in rf circuits. The third series is obtained by the experimental platform of the FEMTO-ST laboratory with EVG620 Automated Mask Alignment System Nanoimprint lithography in a clean room. To examine the reliability of this gas sensor at room temperature, it was exposed to different ammonia gas concentrations from 100 to 500 ppm in an argon flow to eliminate coadsorption phenomena. According to the recorded frequency responses, the reflection and transmission coefficients show a change of resonance amplitude due to electrical characteristic modification. This can be correlated to the presence of gaseous ammonia. The chemical nature of the sensitive material layer has a major influence at the excited frequency range. The process of conception influences the sensor sensitivity. The analysis of the results shows a strong correlation between the injected ammonia concentration and its frequency response. The influence of the critical key parameters cited is discussed here.

SELECTION OF CITATIONS
SEARCH DETAIL
...